Homeowners specifying HomeWerks Worldwide 7141-80 gain 80 CFM at 0.1 in. w.g. (62.9 CFM at 0.25 in. w.g.) where it registers #357 of 607 in quietness (1.1 sones) and delivers 4.1 CFM/W efficacy, venting bathrooms up to 62 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7141-80 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 62.9 CFM
- Noise @ 0.1"
- 1.1 sones (#357/607)
- Efficacy Rank
- 4.1 CFM/W (#821/1,145)
- Static Retention
- 78.6% @ 0.25"
- Motor Draw
- 19.5 W (7.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7141-80 vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62.9 CFM at 0.25 in. w.g. (78.6% retention, 9.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4697554 verifies 7141-80 (series: 7141-80) under HomeWerks Worldwide (31 listed models, qualified 2026-09-02). Lighting kit: Yes. At 4.1 CFM/W (#821 of 1,145, below median tier among 1,145 rated models; more efficient than 26.1% of rated models, 0.6 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 19.5 watts, about 7.1 kWh/yr (~$1.14/yr at $0.16/kWh) for 1 hr/day shower timers or 170.8 kWh/yr (~$27.33/yr) continuously. Closest competing matches include Broan (Canada) EZ80C (80.0 CFM) and Utilitech 7105-08-L (80.0 CFM).
What acoustic percentile does HomeWerks Worldwide 7141-80 occupy among 1,145 bath blowers?
Inspect how HomeWerks Worldwide 7141-80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits HomeWerks Worldwide 7141-80 best?
Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around HomeWerks Worldwide 7141-80 housings.
Where do HomeWerks Worldwide 7141-80 acoustic and static metrics stand?
Compare HomeWerks Worldwide 7141-80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7141-80 / 7141-80 | PD ID 4697554 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (62.9 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.1 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can HomeWerks Worldwide 7141-80 handle taller ceilings or walk-in tub steam?
Evaluate how HomeWerks Worldwide 7141-80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 62 sq ft | 1 CFM/sq ft @ 62.9 CFM |
| Tall Bath (9-ft Ceiling) | Up to 55 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.1 kWh/yr (~$1.14/yr) | 19.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 170.8 kWh/yr (~$27.33/yr) | 19.5 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near HomeWerks Worldwide 7141-80?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan (Canada) EZ80C | 80 / 65.6 CFM | 1.1 sones (Same) | 3.7 CFM/W | 4 in. diameter |
| Utilitech 7105-08-L | 80 / 59.9 CFM | 1.1 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Commercial Electric 7132-12-CE | 80 / 57.1 CFM | 1.1 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Panasonic FV-08VRE2 | 80 / 66.7 CFM | 1.0 sones (-0.10) | 4.3 CFM/W | 4 in. diameter |
| Air King AK80H | 80 / 71.4 CFM | 1.0 sones (-0.10) | 3.8 CFM/W | 4 in. diameter |
Is HomeWerks Worldwide 7141-80 sized right for your shower or tub room?
Check whether HomeWerks Worldwide 7141-80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Who should not install HomeWerks Worldwide 7141-80 in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting HomeWerks Worldwide 7141-80 for residential use.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Moisture load fits 62.9 CFM net static output
- Primary match: Collar pairs with 4 in. diameter duct straight outdoors
Which code checks and cost facts matter for HomeWerks Worldwide 7141-80?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to HomeWerks Worldwide 7141-80.
When is HomeWerks Worldwide 7141-80 undersized or poorly matched for a bath renovation?
Skip HomeWerks Worldwide 7141-80 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check HomeWerks Worldwide 7141-80 CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, HomeWerks Worldwide 7141-80 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does HomeWerks Worldwide 7141-80 sound output compare to noisy contractor-grade fans?
Rated at 1.1 sones, HomeWerks Worldwide 7141-80 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define HomeWerks Worldwide 7141-80?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can HomeWerks Worldwide 7141-80 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7141-80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7141-80?
HomeWerks Worldwide 7141-80 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7141-80's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7141-80's safe coverage footprint from 50 sq ft to 44 sq ft.
Does HomeWerks Worldwide 7141-80 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7141-80 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)