Skip to main content
Grant Estimator

Broan (Canada) EZ80C Exhaust Fan Specifications

ENERGY STAR PD #2406836 · Bathroom/Utility Room · Qualified 2023-01-13
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan (Canada) EZ80C tests at 80 CFM free discharge (65.6 CFM at 0.25 in. w.g.) and registers #357 of 607 in quietness (1.1 sones) and delivers 3.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 65 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan (Canada) EZ80C Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 65.6 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
3.7 CFM/W (#987/1,145)
Static Retention
82.0% @ 0.25"
Motor Draw
21.6 W (7.9 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan (Canada) EZ80C vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 65.6 CFM at 0.25 in. w.g. (82.0% retention, 5.7 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places EZ80C (series: EZ FIT) (PD #2406836) among 3 Broan (Canada) entries qualified through 2023-01-13. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 21.6 watts, about 7.9 kWh/yr (~$1.26/yr at $0.16/kWh) for 1 hr/day shower timers or 189.2 kWh/yr (~$30.27/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-80-G4 (80.0 CFM) and Utilitech 7105-08-L (80.0 CFM).

Does Broan (Canada) EZ80C fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan (Canada) EZ80C at 1.1 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

Why avoid unvented attic termination with Broan (Canada) EZ80C?

Under ASHRAE 62.2 best practice, Broan (Canada) EZ80C needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan (Canada) EZ80C?

Before cutting ceiling drywall or sizing attic transitions for Broan (Canada) EZ80C, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (Canada) (3 models) ENERGY STAR Certified Partner
Model Number & Series EZ80C / EZ FIT PD ID 2406836 (Qualified 2023-01-13)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (65.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Broan (Canada) EZ80C?

Bathroom ventilation sizing below maps Broan (Canada) EZ80C motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan (Canada) EZ80C
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 65 sq ft1 CFM/sq ft @ 65.6 CFM
Tall Bath (9-ft Ceiling)Up to 58 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.9 kWh/yr (~$1.26/yr)21.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2189.2 kWh/yr (~$30.27/yr)21.6 W x 8,760 hrs / 1,000

What peer models sit nearest Broan (Canada) EZ80C in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan (Canada) EZ80C.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7141-80-G4 80 / 61.2 CFM 1.1 sones (Same) 3.7 CFM/W 4 in. diameter
Utilitech 7105-08-L 80 / 59.9 CFM 1.1 sones (Same) 3.5 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-80 80 / 62.9 CFM 1.1 sones (Same) 4.1 CFM/W 4 in. diameter
Commercial Electric 7132-12-CE 80 / 57.1 CFM 1.1 sones (Same) 3.3 CFM/W 4 in. diameter
Broan EZ80 80 / 65.6 CFM 1.0 sones (-0.10) 3.7 CFM/W 4 in. diameter

What percentage of room demand does Broan (Canada) EZ80C cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan (Canada) EZ80C tested delivery.

When does Broan (Canada) EZ80C fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan (Canada) EZ80C.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 65.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 1.1 sones up to 65 sq ft
  • Target scenario: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Broan (Canada) EZ80C?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan (Canada) EZ80C.

Will Broan (Canada) EZ80C disturb adjacent bedrooms during night use?

Acoustic measurement places Broan (Canada) EZ80C at 1.1 sones, meaning it produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites when paired with an insulated exterior damper.

Does running Broan (Canada) EZ80C continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Broan (Canada) EZ80C draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Broan (Canada) EZ80C pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan (Canada) EZ80C's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan (Canada) EZ80C?

Broan (Canada) EZ80C features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan (Canada) EZ80C's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan (Canada) EZ80C's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Broan (Canada) EZ80C code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan (Canada) EZ80C clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Broan (Canada) EZ80C?

Do not force Broan (Canada) EZ80C into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Broan (Canada) EZ80C retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Broan (Canada) EZ80C produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)