In EPA dataset 8dv7-nngq, VENTECHLATION BPT13-12EN-T tests at 50 CFM free discharge (49.3 CFM at 0.25 in. w.g.) and registers #380 of 607 in quietness (1.2 sones) and delivers 3.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 49 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT13-12EN-T Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 49.3 CFM
- Noise @ 0.1"
- 1.2 sones (#380/607)
- Efficacy Rank
- 3.7 CFM/W (#987/1,145)
- Static Retention
- 98.6% @ 0.25"
- Motor Draw
- 13.5 W (4.9 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does VENTECHLATION BPT13-12EN-T vs. 1,145-Model ENERGY STAR Benchmarks show?
Moderate audible output of 1.2 sones (#380 of 607 rated models, 0.20 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 49.3 CFM out of 50 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
VENTECHLATION maintains 12 active ENERGY STAR blowers; BPT13-12EN-T (series: BPT) (PD #4429503) gained qualification on 2025-06-06. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 13.5 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 118.3 kWh/yr (~$18.93/yr) continuously. Closest competing matches include Tech Drive TD-BF-17 (50.0 CFM) and Commercial Electric BPT13-12EN (50.0 CFM).
Does VENTECHLATION BPT13-12EN-T fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with VENTECHLATION BPT13-12EN-T at 1.2 sones.
Why avoid unvented attic termination with VENTECHLATION BPT13-12EN-T?
Under ASHRAE 62.2 best practice, VENTECHLATION BPT13-12EN-T needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern VENTECHLATION BPT13-12EN-T?
Before cutting ceiling drywall or sizing attic transitions for VENTECHLATION BPT13-12EN-T, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT13-12EN-T / BPT | PD ID 4429503 (Qualified 2025-06-06) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (49.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | NO (1.2 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit VENTECHLATION BPT13-12EN-T?
Bathroom ventilation sizing below maps VENTECHLATION BPT13-12EN-T motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 49 sq ft | 1 CFM/sq ft @ 49.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 43 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.9 kWh/yr (~$0.78/yr) | 13.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 118.3 kWh/yr (~$18.93/yr) | 13.5 W x 8,760 hrs / 1,000 |
What peer models sit nearest VENTECHLATION BPT13-12EN-T in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to VENTECHLATION BPT13-12EN-T.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-17 | 50 / 49.3 CFM | 1.2 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| Commercial Electric BPT13-12EN | 50 / 49.3 CFM | 1.0 sones (-0.20) | 3.7 CFM/W | 3 in. diameter |
| MaxLite EBF17-50-1-W | 50 / 49.3 CFM | 1.0 sones (-0.20) | 3.7 CFM/W | 3 in. diameter |
| Tech Drive FA-BF-01-L | 50 / 45.1 CFM | 1.0 sones (-0.20) | 3.8 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7140-50 | 50 / 43.4 CFM | 1.0 sones (-0.20) | 3.0 CFM/W | 4 in. diameter |
What percentage of room demand does VENTECHLATION BPT13-12EN-T cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against VENTECHLATION BPT13-12EN-T tested delivery.
What plumbing or duct constraints rule out VENTECHLATION BPT13-12EN-T?
Compare where VENTECHLATION BPT13-12EN-T excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 49.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 1.2 sones up to 49 sq ft
- Suited to: Paired with rigid galvanized 3 in. diameter transition
Where do official rules set limits for VENTECHLATION BPT13-12EN-T?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing VENTECHLATION BPT13-12EN-T.
Why might a contractor swap VENTECHLATION BPT13-12EN-T for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, VENTECHLATION BPT13-12EN-T lacks adequate reserve.
How does VENTECHLATION BPT13-12EN-T handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., VENTECHLATION BPT13-12EN-T yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.
Is VENTECHLATION BPT13-12EN-T quiet enough for a primary bedroom bathroom?
At 1.2 sones, VENTECHLATION BPT13-12EN-T produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is VENTECHLATION BPT13-12EN-T energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can VENTECHLATION BPT13-12EN-T pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT13-12EN-T's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION BPT13-12EN-T?
VENTECHLATION BPT13-12EN-T features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION BPT13-12EN-T's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT13-12EN-T's safe coverage footprint from 50 sq ft to 44 sq ft.
Can VENTECHLATION BPT13-12EN-T serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: VENTECHLATION BPT13-12EN-T supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)