In EPA dataset 8dv7-nngq, MaxLite EBF17-50-1-W tests at 50 CFM free discharge (49.3 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.7 CFM/W efficacy, meeting residential IRC M1505 sizing up to 49 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside MaxLite EBF17-50-1-W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 49.3 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.7 CFM/W (#987/1,145)
Static Retention
98.6% @ 0.25"
Motor Draw
13.5 W (4.9 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does MaxLite EBF17-50-1-W vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 49.3 CFM out of 50 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms MaxLite EBF17-50-1-W (series: EBF) under PD #4520334 (1 model registered, 2026-01-07). Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 13.5 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 118.3 kWh/yr (~$18.93/yr) continuously. Closest competing matches include Commercial Electric BPT13-12EN (50.0 CFM) and Tech Drive FA-BF-01-L (50.0 CFM).

Does MaxLite EBF17-50-1-W fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with MaxLite EBF17-50-1-W at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with MaxLite EBF17-50-1-W?

Under ASHRAE 62.2 best practice, MaxLite EBF17-50-1-W needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern MaxLite EBF17-50-1-W?

Before cutting ceiling drywall or sizing attic transitions for MaxLite EBF17-50-1-W, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share MaxLite (1 model) ENERGY STAR Certified Partner
Model Number & Series EBF17-50-1-W / EBF PD ID 4520334 (Qualified 2026-01-07)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (49.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit MaxLite EBF17-50-1-W?

Bathroom ventilation sizing below maps MaxLite EBF17-50-1-W motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for MaxLite EBF17-50-1-W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 49 sq ft1 CFM/sq ft @ 49.3 CFM
Tall Bath (9-ft Ceiling)Up to 43 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.9 kWh/yr (~$0.78/yr)13.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2118.3 kWh/yr (~$18.93/yr)13.5 W x 8,760 hrs / 1,000

What peer models sit nearest MaxLite EBF17-50-1-W in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to MaxLite EBF17-50-1-W.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric BPT13-12EN 50 / 49.3 CFM 1.0 sones (Same) 3.7 CFM/W 3 in. diameter
Tech Drive FA-BF-01-L 50 / 45.1 CFM 1.0 sones (Same) 3.8 CFM/W 3 in. diameter
HomeWerks Worldwide 7140-50 50 / 43.4 CFM 1.0 sones (Same) 3.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7140-50-G3 50 / 36.1 CFM 1.0 sones (Same) 3.0 CFM/W 4 in. diameter
VOTATEC VO-FN4W18-AC-50 50 / 43.4 CFM 1.0 sones (Same) 3.0 CFM/W 4 in. diameter

What percentage of room demand does MaxLite EBF17-50-1-W cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against MaxLite EBF17-50-1-W tested delivery.

When does MaxLite EBF17-50-1-W fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering MaxLite EBF17-50-1-W.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 49.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Recommended when: Target comfort around 1.0 sones up to 49 sq ft
  • Target scenario: Paired with rigid galvanized 3 in. diameter transition

Where do official rules set limits for MaxLite EBF17-50-1-W?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing MaxLite EBF17-50-1-W.

Does running MaxLite EBF17-50-1-W continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of MaxLite EBF17-50-1-W draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can MaxLite EBF17-50-1-W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from MaxLite EBF17-50-1-W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing MaxLite EBF17-50-1-W?

MaxLite EBF17-50-1-W features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change MaxLite EBF17-50-1-W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing MaxLite EBF17-50-1-W's safe coverage footprint from 50 sq ft to 44 sq ft.

Is MaxLite EBF17-50-1-W code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), MaxLite EBF17-50-1-W clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than MaxLite EBF17-50-1-W?

Do not force MaxLite EBF17-50-1-W into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does MaxLite EBF17-50-1-W retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, MaxLite EBF17-50-1-W produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.

Will MaxLite EBF17-50-1-W disturb adjacent bedrooms during night use?

Acoustic measurement places MaxLite EBF17-50-1-W at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories