Skip to main content
Grant Estimator

RAB CEP8S Exhaust Fan Specifications

ENERGY STAR PD #4718097 · Bathroom/Utility Room · Qualified 2026-10-07
Verified Specification Summary

Certified by EPA ENERGY STAR, RAB CEP8S delivers 50 CFM free-air (48.8 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 5.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 48 sq ft (8-ft height) or 43 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside RAB CEP8S Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 48.8 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
5.1 CFM/W (#507/1,145)
Static Retention
97.6% @ 0.25"
Motor Draw
9.8 W (3.6 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does RAB CEP8S vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 48.8 CFM out of 50 CFM (97.6% retention, 9.9 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

RAB maintains 3 active ENERGY STAR blowers; CEP8S (series: Bathroom Exhaust Fans) (PD #4718097) gained qualification on 2026-10-07. Lighting kit: Yes. At 5.1 CFM/W (#507 of 1,145, top 44.8% of 1,145 rated models, more efficient than 55.2% of rated models, 0.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.8 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 85.8 kWh/yr (~$13.73/yr) continuously. Closest competing matches include Commercial Electric BF1101 (50.0 CFM) and Commercial Electric BF1103 (50.0 CFM).

How noisy is RAB CEP8S compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while RAB CEP8S measures 1.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why does rigid 3 in. diameter ducting protect RAB CEP8S airflow?

Connecting RAB CEP8S through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify RAB CEP8S performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for RAB CEP8S lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share RAB (3 models) ENERGY STAR Certified Partner
Model Number & Series CEP8S / Bathroom Exhaust Fans PD ID 4718097 (Qualified 2026-10-07)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (48.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit RAB CEP8S?

Calculated coverage metrics translate RAB CEP8S airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for RAB CEP8S
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 48 sq ft1 CFM/sq ft @ 48.8 CFM
Tall Bath (9-ft Ceiling)Up to 43 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.6 kWh/yr (~$0.58/yr)9.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.285.8 kWh/yr (~$13.73/yr)9.8 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to RAB CEP8S?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric BF1101 50 / 45.9 CFM 1.0 sones (Same) 5.0 CFM/W 3 in. diameter
Commercial Electric BF1103 50 / 46.8 CFM 1.0 sones (Same) 5.2 CFM/W 3 in. diameter
Tech Drive FA-BF-01-L 50 / 45.1 CFM 1.0 sones (Same) 3.8 CFM/W 3 in. diameter
Commercial Electric BPT13-12EN 50 / 49.3 CFM 1.0 sones (Same) 3.7 CFM/W 3 in. diameter
MaxLite EBF17-50-1-W 50 / 49.3 CFM 1.0 sones (Same) 3.7 CFM/W 3 in. diameter

Does RAB CEP8S match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check RAB CEP8S percentage capacity without sending data.

Which bath layouts should avoid specifying RAB CEP8S?

Match RAB CEP8S directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Supplementary continuous trickle ventilation
  • Optimal use: Collar pairs with 3 in. diameter duct straight outdoors

Which homeowner questions come up most for RAB CEP8S?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around RAB CEP8S.

Where does RAB CEP8S run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with RAB CEP8S.

What happens to RAB CEP8S CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, RAB CEP8S moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.

Where does RAB CEP8S sit on acoustic comfort for senior homeowners?

Measuring 1.0 sones, RAB CEP8S operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does RAB CEP8S cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running RAB CEP8S 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can RAB CEP8S pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from RAB CEP8S's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing RAB CEP8S?

RAB CEP8S features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change RAB CEP8S's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing RAB CEP8S's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can RAB CEP8S ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), RAB CEP8S covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories