Commercial Electric BF1101 Exhaust Fan Specifications

ENERGY STAR PD #3531174 · Bathroom/Utility Room · Qualified 2024-05-24
Verified Specification Summary

Rated for 50 CFM open-air (45.9 CFM at 0.25 in. w.g.), Commercial Electric BF1101 registers #265 of 607 in quietness (1.0 sones) and delivers 5.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 45 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1101 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 45.9 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
5.0 CFM/W (#514/1,145)
Static Retention
91.8% @ 0.25"
Motor Draw
10.0 W (3.6 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Commercial Electric BF1101 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 45.9 CFM out of 50 CFM (91.8% retention, 4.1 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Commercial Electric maintains 15 active ENERGY STAR blowers; BF1101 (series: BF1101) (PD #3531174) gained qualification on 2024-05-24. Lighting kit: No. At 5.0 CFM/W (#514 of 1,145, top 45.2% of 1,145 rated models, more efficient than 54.8% of rated models, 0.3 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 10.0 watts, about 3.6 kWh/yr (~$0.58/yr at $0.16/kWh) for 1 hr/day shower timers or 87.6 kWh/yr (~$14.02/yr) continuously. Closest competing matches include RAB CEP8S (50.0 CFM) and Tech Drive FA-BF-01-L (50.0 CFM).

How does Commercial Electric BF1101 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Commercial Electric BF1101 (1.0 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

How do flex elbows choke Commercial Electric BF1101 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 3 in. diameter metal pipe keeps Commercial Electric BF1101 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Commercial Electric BF1101 meet residential exhaust fan code specs?

Inspect Commercial Electric BF1101 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Commercial Electric (15 models) ENERGY STAR Certified Partner
Model Number & Series BF1101 / BF1101 PD ID 3531174 (Qualified 2024-05-24)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (45.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Commercial Electric BF1101 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Commercial Electric BF1101 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Commercial Electric BF1101
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 45 sq ft1 CFM/sq ft @ 45.9 CFM
Tall Bath (9-ft Ceiling)Up to 40 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.6 kWh/yr (~$0.58/yr)10.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.287.6 kWh/yr (~$14.02/yr)10.0 W x 8,760 hrs / 1,000

Which competing models share Commercial Electric BF1101 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
RAB CEP8S 50 / 48.8 CFM 1.0 sones (Same) 5.1 CFM/W 3 in. diameter
Tech Drive FA-BF-01-L 50 / 45.1 CFM 1.0 sones (Same) 3.8 CFM/W 3 in. diameter
MaxLite EBF17-50-1-W 50 / 49.3 CFM 1.0 sones (Same) 3.7 CFM/W 3 in. diameter
Air King BFQL50 50 / 39.3 CFM 0.8 sones (-0.20) 4.4 CFM/W 4 in. diameter
Air King WML50 50 / 39.3 CFM 0.8 sones (-0.20) 4.4 CFM/W 4 in. diameter

How much airflow margin does Commercial Electric BF1101 give your bath?

Run a quick local room-volume check for Commercial Electric BF1101 by entering square footage and ceiling height to spot under-vented steam risks early.

What plumbing or duct constraints rule out Commercial Electric BF1101?

Compare where Commercial Electric BF1101 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 45 sq ft with 8-ft ceilings (40 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 3 in. diameter

What should homeowners verify first about Commercial Electric BF1101?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Commercial Electric BF1101.

Can Commercial Electric BF1101 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Commercial Electric BF1101 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Commercial Electric BF1101 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Commercial Electric BF1101 lacks adequate reserve.

How does Commercial Electric BF1101 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Commercial Electric BF1101 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

Is Commercial Electric BF1101 quiet enough for a primary bedroom bathroom?

At 1.0 sones, Commercial Electric BF1101 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Commercial Electric BF1101 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Commercial Electric BF1101 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1101's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Commercial Electric BF1101?

Commercial Electric BF1101 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Commercial Electric BF1101's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1101's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories