Homeowners specifying Tech Drive FA-BF-01-L gain 50 CFM at 0.1 in. w.g. (45.1 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 3.8 CFM/W efficacy, venting bathrooms up to 45 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive FA-BF-01-L Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 45.1 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.8 CFM/W (#951/1,145)
- Static Retention
- 90.2% @ 0.25"
- Motor Draw
- 13.2 W (4.8 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does Tech Drive FA-BF-01-L vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 45.1 CFM out of 50 CFM (90.2% retention, 2.5 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Tech Drive registers 27 certified models, with SKU FA-BF-01-L (series: FA) (PD #3892188) certified since 2024-12-20. Lighting kit: Yes. At 3.8 CFM/W (#951 of 1,145, below median tier among 1,145 rated models; more efficient than 13.9% of rated models, 0.9 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 13.2 watts, about 4.8 kWh/yr (~$0.77/yr at $0.16/kWh) for 1 hr/day shower timers or 115.6 kWh/yr (~$18.50/yr) continuously. Closest competing matches include Commercial Electric BPT13-12EN (50.0 CFM) and MaxLite EBF17-50-1-W (50.0 CFM).
What acoustic percentile does Tech Drive FA-BF-01-L occupy among 1,145 bath blowers?
Inspect how Tech Drive FA-BF-01-L positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits Tech Drive FA-BF-01-L best?
Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Tech Drive FA-BF-01-L housings.
Where do Tech Drive FA-BF-01-L acoustic and static metrics stand?
Compare Tech Drive FA-BF-01-L published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Tech Drive (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | FA-BF-01-L / FA | PD ID 3892188 (Qualified 2024-12-20) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (45.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
Can Tech Drive FA-BF-01-L handle taller ceilings or walk-in tub steam?
Evaluate how Tech Drive FA-BF-01-L scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 45 sq ft | 1 CFM/sq ft @ 45.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 40 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 4.8 kWh/yr (~$0.77/yr) | 13.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 115.6 kWh/yr (~$18.50/yr) | 13.2 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near Tech Drive FA-BF-01-L?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Commercial Electric BPT13-12EN | 50 / 49.3 CFM | 1.0 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| MaxLite EBF17-50-1-W | 50 / 49.3 CFM | 1.0 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7140-50 | 50 / 43.4 CFM | 1.0 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7140-50-G3 | 50 / 36.1 CFM | 1.0 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| VOTATEC VO-FN4W18-AC-50 | 50 / 43.4 CFM | 1.0 sones (Same) | 3.0 CFM/W | 4 in. diameter |
Is Tech Drive FA-BF-01-L sized right for your shower or tub room?
Check whether Tech Drive FA-BF-01-L clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Who should not install Tech Drive FA-BF-01-L in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Tech Drive FA-BF-01-L for residential use.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Ideal fit: Supplementary continuous trickle ventilation
- Primary match: Collar pairs with 3 in. diameter duct straight outdoors
Which code checks and cost facts matter for Tech Drive FA-BF-01-L?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Tech Drive FA-BF-01-L.
When is Tech Drive FA-BF-01-L undersized or poorly matched for a bath renovation?
Skip Tech Drive FA-BF-01-L if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Tech Drive FA-BF-01-L CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Tech Drive FA-BF-01-L registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.
How does Tech Drive FA-BF-01-L sound output compare to noisy contractor-grade fans?
Rated at 1.0 sones, Tech Drive FA-BF-01-L operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Tech Drive FA-BF-01-L?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Tech Drive FA-BF-01-L pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive FA-BF-01-L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Tech Drive FA-BF-01-L?
Tech Drive FA-BF-01-L features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Tech Drive FA-BF-01-L's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive FA-BF-01-L's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Tech Drive FA-BF-01-L satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Tech Drive FA-BF-01-L clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)