Tested under HVI protocols, the Revent RVSH50 exhaust unit achieves 50 CFM at 0.1 in. w.g. (50 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones) and delivers 9.1 CFM/W efficacy, covering standard baths up to 50 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVSH50 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 50 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 9.1 CFM/W (#292/1,145)
- Static Retention
- 100.0% @ 0.25"
- Motor Draw
- 5.5 W (2.0 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Revent RVSH50 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 50 CFM out of 50 CFM (100.0% retention, 12.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Revent RVSH50 (series: ReVent) under PD #4020780 (40 models registered, 2025-04-25). Lighting kit: No. At 9.1 CFM/W (#292 of 1,145, top 25.9% of 1,145 rated models, more efficient than 74.1% of rated models, 4.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 5.5 watts, about 2.0 kWh/yr (~$0.32/yr at $0.16/kWh) for 1 hr/day shower timers or 48.2 kWh/yr (~$7.71/yr) continuously. Closest competing matches include Hampton Bay 1001357397 (50.0 CFM) and Tech Drive TD-BF-13 (50.0 CFM).
Where do Revent RVSH50 sones rank across EPA ENERGY STAR fans?
Comparing Revent RVSH50 (1.0 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Revent RVSH50 CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Revent RVSH50, preventing premature peeling paint and mold growth.
How does Revent RVSH50 measure up on airflow and noise ratings?
Each row below breaks down Revent RVSH50 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Revent (40 models) | ENERGY STAR Certified Partner |
| Model Number & Series | RVSH50 / ReVent | PD ID 4020780 (Qualified 2025-04-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (50 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Revent RVSH50 CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 50 sq ft | 1 CFM/sq ft @ 50 CFM |
| Tall Bath (9-ft Ceiling) | Up to 44 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.0 kWh/yr (~$0.32/yr) | 5.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 48.2 kWh/yr (~$7.71/yr) | 5.5 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Revent RVSH50?
Compare Revent RVSH50 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hampton Bay 1001357397 | 50 / 47 CFM | 1.0 sones (Same) | 8.1 CFM/W | 3 in. diameter |
| Tech Drive TD-BF-13 | 50 / 47 CFM | 1.0 sones (Same) | 8.1 CFM/W | 3 in. diameter |
| VENTECHLATION BPT12-13E | 50 / 47 CFM | 1.0 sones (Same) | 8.1 CFM/W | 3 in. diameter |
| Hampton Bay 7114-02 | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7114-02-HW | 50 / 36.9 CFM | 1.0 sones (Same) | 10.2 CFM/W | 3 in. diameter |
Can you size Revent RVSH50 for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Revent RVSH50 verified capacity.
What plumbing or duct constraints rule out Revent RVSH50?
Compare where Revent RVSH50 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 50 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 1.0 sones up to 50 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Revent RVSH50?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Revent RVSH50.
Is Revent RVSH50 quiet enough for a primary bedroom bathroom?
At 1.0 sones, Revent RVSH50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Revent RVSH50 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Revent RVSH50 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVSH50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Revent RVSH50?
Revent RVSH50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Revent RVSH50's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVSH50's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Revent RVSH50 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Revent RVSH50 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Revent RVSH50 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Revent RVSH50 lacks adequate reserve.
How does Revent RVSH50 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Revent RVSH50 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)