Revent RVS50 Exhaust Fan Specifications

ENERGY STAR PD #3994116 · Bathroom/Utility Room · Qualified 2025-01-24
Verified Specification Summary

In EPA dataset 8dv7-nngq, Revent RVS50 tests at 50 CFM free discharge (50 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 9.1 CFM/W efficacy, meeting residential IRC M1505 sizing up to 50 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVS50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 50 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
9.1 CFM/W (#292/1,145)
Static Retention
100.0% @ 0.25"
Motor Draw
5.5 W (2.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVS50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 50 CFM out of 50 CFM (100.0% retention, 12.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Revent RVS50 (series: ReVent) under PD #3994116 (40 models registered, 2025-01-24). Lighting kit: No. At 9.1 CFM/W (#292 of 1,145, top 25.9% of 1,145 rated models, more efficient than 74.1% of rated models, 4.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 5.5 watts, about 2.0 kWh/yr (~$0.32/yr at $0.16/kWh) for 1 hr/day shower timers or 48.2 kWh/yr (~$7.71/yr) continuously. Closest competing matches include Hampton Bay 1001357397 (50.0 CFM) and Tech Drive TD-BF-13 (50.0 CFM).

Does Revent RVS50 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Revent RVS50 at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with Revent RVS50?

Under ASHRAE 62.2 best practice, Revent RVS50 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Revent RVS50?

Before cutting ceiling drywall or sizing attic transitions for Revent RVS50, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVS50 / ReVent PD ID 3994116 (Qualified 2025-01-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (50 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Revent RVS50?

Bathroom ventilation sizing below maps Revent RVS50 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Revent RVS50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 50 sq ft1 CFM/sq ft @ 50 CFM
Tall Bath (9-ft Ceiling)Up to 44 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.0 kWh/yr (~$0.32/yr)5.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.248.2 kWh/yr (~$7.71/yr)5.5 W x 8,760 hrs / 1,000

What peer models sit nearest Revent RVS50 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Revent RVS50.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hampton Bay 1001357397 50 / 47 CFM 1.0 sones (Same) 8.1 CFM/W 3 in. diameter
Tech Drive TD-BF-13 50 / 47 CFM 1.0 sones (Same) 8.1 CFM/W 3 in. diameter
VENTECHLATION BPT12-13E 50 / 47 CFM 1.0 sones (Same) 8.1 CFM/W 3 in. diameter
Hampton Bay 7114-02 50 / 36.9 CFM 1.0 sones (Same) 10.2 CFM/W 3 in. diameter
HomeWerks Worldwide 7114-02-HW 50 / 36.9 CFM 1.0 sones (Same) 10.2 CFM/W 3 in. diameter

What percentage of room demand does Revent RVS50 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Revent RVS50 tested delivery.

Who should not install Revent RVS50 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Revent RVS50 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 50 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.0 sones up to 50 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Revent RVS50?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Revent RVS50.

Why check Revent RVS50 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Revent RVS50 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Revent RVS50 sound output compare to noisy contractor-grade fans?

Rated at 1.0 sones, Revent RVS50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Revent RVS50?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Revent RVS50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVS50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVS50?

Revent RVS50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVS50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVS50's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Revent RVS50 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Revent RVS50 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Revent RVS50 undersized or poorly matched for a bath renovation?

Skip Revent RVS50 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources