Certified by EPA ENERGY STAR, VENTECHLATION BPT12-13E delivers 50 CFM free-air (47 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 8.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 47 sq ft (8-ft height) or 41 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION BPT12-13E Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 47 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 8.1 CFM/W (#338/1,145)
- Static Retention
- 94.0% @ 0.25"
- Motor Draw
- 6.2 W (2.3 kWh/yr)
- Duct & Tier
- 3 in. diameter · Standard

What does VENTECHLATION BPT12-13E vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 47 CFM out of 50 CFM (94.0% retention, 6.3 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
VENTECHLATION maintains 12 active ENERGY STAR blowers; BPT12-13E (series: BPT) (PD #4429501) gained qualification on 2025-06-06. Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.2 watts, about 2.3 kWh/yr (~$0.37/yr at $0.16/kWh) for 1 hr/day shower timers or 54.3 kWh/yr (~$8.69/yr) continuously. Closest competing matches include Hampton Bay 1001357397 (50.0 CFM) and Tech Drive TD-BF-13 (50.0 CFM).
How noisy is VENTECHLATION BPT12-13E compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while VENTECHLATION BPT12-13E measures 1.0 sones across the 1,145-model registry.
Why does rigid 3 in. diameter ducting protect VENTECHLATION BPT12-13E airflow?
Connecting VENTECHLATION BPT12-13E through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify VENTECHLATION BPT12-13E performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for VENTECHLATION BPT12-13E lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BPT12-13E / BPT | PD ID 4429501 (Qualified 2025-06-06) |
| Duct Connection | 3 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (47 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit VENTECHLATION BPT12-13E?
Calculated coverage metrics translate VENTECHLATION BPT12-13E airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 47 sq ft | 1 CFM/sq ft @ 47 CFM |
| Tall Bath (9-ft Ceiling) | Up to 41 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 2.3 kWh/yr (~$0.37/yr) | 6.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 54.3 kWh/yr (~$8.69/yr) | 6.2 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to VENTECHLATION BPT12-13E?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hampton Bay 1001357397 | 50 / 47 CFM | 1.0 sones (Same) | 8.1 CFM/W | 3 in. diameter |
| Tech Drive TD-BF-13 | 50 / 47 CFM | 1.0 sones (Same) | 8.1 CFM/W | 3 in. diameter |
| Revent RVL50 | 50 / 47 CFM | 1.1 sones (+0.10) | 7.6 CFM/W | 4 in. diameter |
| Revent RVLH50 | 50 / 47 CFM | 1.1 sones (+0.10) | 7.6 CFM/W | 4 in. diameter |
| Revent RVS50 | 50 / 50 CFM | 1.0 sones (Same) | 9.1 CFM/W | 4 in. diameter |
Does VENTECHLATION BPT12-13E match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check VENTECHLATION BPT12-13E percentage capacity without sending data.
Which bath layouts should avoid specifying VENTECHLATION BPT12-13E?
Match VENTECHLATION BPT12-13E directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Best for: Supplementary continuous trickle ventilation
- Optimal use: Collar pairs with 3 in. diameter duct straight outdoors
Which homeowner questions come up most for VENTECHLATION BPT12-13E?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around VENTECHLATION BPT12-13E.
What bathroom square footage can VENTECHLATION BPT12-13E ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION BPT12-13E covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does VENTECHLATION BPT12-13E run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with VENTECHLATION BPT12-13E.
What happens to VENTECHLATION BPT12-13E CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, VENTECHLATION BPT12-13E moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 3 in. diameter collar.
Where does VENTECHLATION BPT12-13E sit on acoustic comfort for senior homeowners?
Measuring 1.0 sones, VENTECHLATION BPT12-13E operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does VENTECHLATION BPT12-13E cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running VENTECHLATION BPT12-13E 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can VENTECHLATION BPT12-13E pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION BPT12-13E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION BPT12-13E?
VENTECHLATION BPT12-13E features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION BPT12-13E's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION BPT12-13E's safe coverage footprint from 50 sq ft to 44 sq ft.