Verified Specification Summary

The Revent RVL50 (ReVent) moves 50 CFM at 0.1 in. w.g. (47 CFM at 0.25 in. w.g.), registers #357 of 607 in quietness (1.1 sones), and delivers 7.6 CFM/W efficacy, sizing bathrooms up to 47 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVL50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 47 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
7.6 CFM/W (#380/1,145)
Static Retention
94.0% @ 0.25"
Motor Draw
6.6 W (2.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVL50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 47 CFM out of 50 CFM (94.0% retention, 6.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Revent maintains 40 active ENERGY STAR blowers; RVL50 (series: ReVent) (PD #3994117) gained qualification on 2025-01-24. Lighting kit: Yes. At 7.6 CFM/W (#380 of 1,145, top 34.0% of 1,145 rated models, more efficient than 66.0% of rated models, 2.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.6 watts, about 2.4 kWh/yr (~$0.38/yr at $0.16/kWh) for 1 hr/day shower timers or 57.8 kWh/yr (~$9.25/yr) continuously. Closest competing matches include Hampton Bay 1001357397 (50.0 CFM) and Tech Drive TD-BF-13 (50.0 CFM).

Where does Revent RVL50 sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.1 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

How does duct geometry alter Revent RVL50 static pressure?

Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Revent RVL50?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Revent RVL50 alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVL50 / ReVent PD ID 3994117 (Qualified 2025-01-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (47 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How much bathroom area can Revent RVL50 ventilate safely?

Sizing outputs below convert Revent RVL50 tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Revent RVL50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 47 sq ft1 CFM/sq ft @ 47 CFM
Tall Bath (9-ft Ceiling)Up to 41 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.4 kWh/yr (~$0.38/yr)6.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.257.8 kWh/yr (~$9.25/yr)6.6 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Revent RVL50 closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hampton Bay 1001357397 50 / 47 CFM 1.0 sones (-0.10) 8.1 CFM/W 3 in. diameter
Tech Drive TD-BF-13 50 / 47 CFM 1.0 sones (-0.10) 8.1 CFM/W 3 in. diameter
VENTECHLATION BPT12-13E 50 / 47 CFM 1.0 sones (-0.10) 8.1 CFM/W 3 in. diameter
Revent RVLH50 50 / 47 CFM 1.1 sones (Same) 7.6 CFM/W 4 in. diameter
Commercial Electric BF1103 50 / 46.8 CFM 1.0 sones (-0.10) 5.2 CFM/W 3 in. diameter

Will Revent RVL50 clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Revent RVL50 satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

Which bath layouts should avoid specifying Revent RVL50?

Match Revent RVL50 directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Best for: Bathroom floor <= 47 sq ft with 8-ft ceilings (41 sq ft at 9-ft height)
  • Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter

What key rules and numbers govern Revent RVL50?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Revent RVL50.

What bathroom square footage can Revent RVL50 ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Revent RVL50 covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Revent RVL50 run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Revent RVL50.

What happens to Revent RVL50 CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Revent RVL50 moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Revent RVL50 sit on acoustic comfort for senior homeowners?

Measuring 1.1 sones, Revent RVL50 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does Revent RVL50 cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Revent RVL50 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Revent RVL50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVL50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVL50?

Revent RVL50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVL50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVL50's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories