Broan LP80=LP80HwithLP80F Exhaust Fan Specifications

ENERGY STAR PD #2248911 · Bathroom/Utility Room · Qualified 2015-10-01
Verified Specification Summary

Tested under HVI protocols, the Broan LP80=LP80HwithLP80F exhaust unit achieves 70 CFM at 0.1 in. w.g. (60.5 CFM at 0.25 in. w.g.), registers #357 of 607 in quietness (1.1 sones) and delivers 3.4 CFM/W efficacy, covering standard baths up to 60 sq ft on a 3 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan LP80=LP80HwithLP80F Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 60.5 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
86.4% @ 0.25"
Motor Draw
20.6 W (7.5 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan LP80=LP80HwithLP80F vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.5 CFM out of 70 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU LP80=LP80HwithLP80F (series: N/A) (PD #2248911) certified since 2015-10-01. Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include HomeWerks Worldwide 7105-10 (70.0 CFM) and HomeWerks Worldwide 7105-10-MB (70.0 CFM).

Where do Broan LP80=LP80HwithLP80F sones rank across EPA ENERGY STAR fans?

Comparing Broan LP80=LP80HwithLP80F (1.1 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

What attic duct routing preserves Broan LP80=LP80HwithLP80F CFM output?

Short straight 3 in. diameter duct paths retain up to ~82% of open-air capacity on Broan LP80=LP80HwithLP80F, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan LP80=LP80HwithLP80F measure up on airflow and noise ratings?

Each row below breaks down Broan LP80=LP80HwithLP80F certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series LP80=LP80HwithLP80F / N/A PD ID 2248911 (Qualified 2015-10-01)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (60.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect Broan LP80=LP80HwithLP80F CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan LP80=LP80HwithLP80F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 60 sq ft1 CFM/sq ft @ 60.5 CFM
Tall Bath (9-ft Ceiling)Up to 53 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2180.5 kWh/yr (~$28.88/yr)20.6 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan LP80=LP80HwithLP80F?

Compare Broan LP80=LP80HwithLP80F side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7105-10 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7105-10-MB 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
Nektra 33003851 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
Tuscany 7105-11-M 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
Commercial Electric 7132-12-CE 80 / 57.1 CFM 1.1 sones (Same) 3.3 CFM/W 4 in. diameter

Can you size Broan LP80=LP80HwithLP80F for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan LP80=LP80HwithLP80F verified capacity.

Who should not install Broan LP80=LP80HwithLP80F in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan LP80=LP80HwithLP80F for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 60.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 1.1 sones up to 60 sq ft
  • Primary match: Paired with rigid galvanized 3 in. diameter transition

How do federal and code standards apply to Broan LP80=LP80HwithLP80F?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan LP80=LP80HwithLP80F.

Why check Broan LP80=LP80HwithLP80F CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan LP80=LP80HwithLP80F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 3 in. diameter duct runs vital.

How does Broan LP80=LP80HwithLP80F sound output compare to noisy contractor-grade fans?

Rated at 1.1 sones, Broan LP80=LP80HwithLP80F produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan LP80=LP80HwithLP80F?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan LP80=LP80HwithLP80F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan LP80=LP80HwithLP80F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan LP80=LP80HwithLP80F?

Broan LP80=LP80HwithLP80F features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan LP80=LP80HwithLP80F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan LP80=LP80HwithLP80F's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan LP80=LP80HwithLP80F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan LP80=LP80HwithLP80F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan LP80=LP80HwithLP80F undersized or poorly matched for a bath renovation?

Skip Broan LP80=LP80HwithLP80F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources