Skip to main content
Grant Estimator

HomeWerks Worldwide 7105-10-MB Exhaust Fan Specifications

ENERGY STAR PD #3629330 · Bathroom/Utility Room · Qualified 2024-05-24
Verified Specification Summary

Certified by EPA ENERGY STAR, HomeWerks Worldwide 7105-10-MB delivers 70 CFM free-air (55.7 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 55 sq ft (8-ft height) or 49 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7105-10-MB Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
70 / 55.7 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
79.6% @ 0.25"
Motor Draw
20.6 W (7.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does HomeWerks Worldwide 7105-10-MB vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 70 CFM open-air to 55.7 CFM at 0.25 in. w.g. (79.6% retention, 8.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places 7105-10-MB (series: 7105-10-MB) (PD #3629330) among 31 HomeWerks Worldwide entries qualified through 2024-05-24. Lighting kit: Yes. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include Nektra 33003851 (70.0 CFM) and Tuscany 7105-11-M (70.0 CFM).

How noisy is HomeWerks Worldwide 7105-10-MB compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while HomeWerks Worldwide 7105-10-MB measures 1.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why does rigid 4 in. diameter ducting protect HomeWerks Worldwide 7105-10-MB airflow?

Connecting HomeWerks Worldwide 7105-10-MB through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify HomeWerks Worldwide 7105-10-MB performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for HomeWerks Worldwide 7105-10-MB lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share HomeWerks Worldwide (31 models) ENERGY STAR Certified Partner
Model Number & Series 7105-10-MB / 7105-10-MB PD ID 3629330 (Qualified 2024-05-24)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (55.7 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit HomeWerks Worldwide 7105-10-MB?

Calculated coverage metrics translate HomeWerks Worldwide 7105-10-MB airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for HomeWerks Worldwide 7105-10-MB
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 55 sq ft1 CFM/sq ft @ 55.7 CFM
Tall Bath (9-ft Ceiling)Up to 49 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2180.5 kWh/yr (~$28.88/yr)20.6 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to HomeWerks Worldwide 7105-10-MB?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Nektra 33003851 70 / 55.7 CFM 1.0 sones (Same) 3.4 CFM/W 4 in. diameter
Tuscany 7105-11-M 70 / 55.7 CFM 1.0 sones (Same) 3.4 CFM/W 4 in. diameter
Broan EZ80 70 / 60.5 CFM 1.1 sones (+0.10) 3.4 CFM/W 3 in. diameter
Broan LP80 70 / 60.5 CFM 1.1 sones (+0.10) 3.4 CFM/W 3 in. diameter
Broan LP80=LP80HwithLP80F 70 / 60.5 CFM 1.1 sones (+0.10) 3.4 CFM/W 3 in. diameter

Does HomeWerks Worldwide 7105-10-MB match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check HomeWerks Worldwide 7105-10-MB percentage capacity without sending data.

When does HomeWerks Worldwide 7105-10-MB fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering HomeWerks Worldwide 7105-10-MB.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Moisture load fits 55.7 CFM net static output
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for HomeWerks Worldwide 7105-10-MB?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around HomeWerks Worldwide 7105-10-MB.

How much airflow does HomeWerks Worldwide 7105-10-MB retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, HomeWerks Worldwide 7105-10-MB produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will HomeWerks Worldwide 7105-10-MB disturb adjacent bedrooms during night use?

Acoustic measurement places HomeWerks Worldwide 7105-10-MB at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running HomeWerks Worldwide 7105-10-MB continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of HomeWerks Worldwide 7105-10-MB draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can HomeWerks Worldwide 7105-10-MB pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7105-10-MB's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing HomeWerks Worldwide 7105-10-MB?

HomeWerks Worldwide 7105-10-MB features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change HomeWerks Worldwide 7105-10-MB's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7105-10-MB's safe coverage footprint from 50 sq ft to 44 sq ft.

Is HomeWerks Worldwide 7105-10-MB code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7105-10-MB clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than HomeWerks Worldwide 7105-10-MB?

Do not force HomeWerks Worldwide 7105-10-MB into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories