In EPA dataset 8dv7-nngq, Broan LP80 tests at 70 CFM free discharge (60.5 CFM at 0.25 in. w.g.) and registers #357 of 607 in quietness (1.1 sones) and delivers 3.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 60 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan LP80 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
70 / 60.5 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
86.4% @ 0.25"
Motor Draw
20.6 W (7.5 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan LP80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 60.5 CFM out of 70 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2248889 verifies LP80 (series: N/A) under Broan (207 listed models, qualified 2015-10-01). Lighting kit: No. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.6 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 180.5 kWh/yr (~$28.88/yr) continuously. Closest competing matches include HomeWerks Worldwide 7105-10 (70.0 CFM) and HomeWerks Worldwide 7105-10-MB (70.0 CFM).

Does Broan LP80 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan LP80 at 1.1 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

Why avoid unvented attic termination with Broan LP80?

Under ASHRAE 62.2 best practice, Broan LP80 needs insulated 3 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan LP80?

Before cutting ceiling drywall or sizing attic transitions for Broan LP80, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series LP80 / N/A PD ID 2248889 (Qualified 2015-10-01)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (60.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Broan LP80?

Bathroom ventilation sizing below maps Broan LP80 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan LP80
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 60 sq ft1 CFM/sq ft @ 60.5 CFM
Tall Bath (9-ft Ceiling)Up to 53 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2180.5 kWh/yr (~$28.88/yr)20.6 W x 8,760 hrs / 1,000

What peer models sit nearest Broan LP80 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan LP80.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7105-10 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7105-10-MB 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
Nektra 33003851 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
Tuscany 7105-11-M 70 / 55.7 CFM 1.0 sones (-0.10) 3.4 CFM/W 4 in. diameter
Commercial Electric 7132-12-CE 80 / 57.1 CFM 1.1 sones (Same) 3.3 CFM/W 4 in. diameter

What percentage of room demand does Broan LP80 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan LP80 tested delivery.

Does Broan LP80 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan LP80 for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 60.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 1.1 sones up to 60 sq ft
  • Best application: Paired with rigid galvanized 3 in. diameter transition

Where do official rules set limits for Broan LP80?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan LP80.

Who should NOT install Broan LP80 in a bathroom remodel?

Avoid specifying Broan LP80 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan LP80 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan LP80 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Broan LP80 occupy in EPA filings?

With 1.1 sones at 0.1 in. w.g., Broan LP80 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites across residential exhaust installations.

How many kWh per year does Broan LP80 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan LP80 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan LP80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan LP80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan LP80?

Broan LP80 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan LP80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan LP80's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan LP80 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan LP80 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories