Skip to main content
Grant Estimator

Revent RVLH50 Exhaust Fan Specifications

ENERGY STAR PD #4517814 · Bathroom/Utility Room · Qualified 2025-10-03
Verified Specification Summary

Rated for 50 CFM open-air (47 CFM at 0.25 in. w.g.), Revent RVLH50 registers #357 of 607 in quietness (1.1 sones) and delivers 7.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 47 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Revent RVLH50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 47 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
7.6 CFM/W (#380/1,145)
Static Retention
94.0% @ 0.25"
Motor Draw
6.6 W (2.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Revent RVLH50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 47 CFM out of 50 CFM (94.0% retention, 6.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Revent RVLH50 (series: ReVent) under PD #4517814 (40 models registered, 2025-10-03). Lighting kit: Yes. At 7.6 CFM/W (#380 of 1,145, top 34.0% of 1,145 rated models, more efficient than 66.0% of rated models, 2.9 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.6 watts, about 2.4 kWh/yr (~$0.38/yr at $0.16/kWh) for 1 hr/day shower timers or 57.8 kWh/yr (~$9.25/yr) continuously. Closest competing matches include Hampton Bay 1001357397 (50.0 CFM) and Tech Drive TD-BF-13 (50.0 CFM).

How does Revent RVLH50 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Revent RVLH50 (1.1 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

How do flex elbows choke Revent RVLH50 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Revent RVLH50 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Revent RVLH50 meet residential exhaust fan code specs?

Inspect Revent RVLH50 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Revent (40 models) ENERGY STAR Certified Partner
Model Number & Series RVLH50 / ReVent PD ID 4517814 (Qualified 2025-10-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (47 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Revent RVLH50 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Revent RVLH50 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Revent RVLH50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 47 sq ft1 CFM/sq ft @ 47 CFM
Tall Bath (9-ft Ceiling)Up to 41 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.4 kWh/yr (~$0.38/yr)6.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.257.8 kWh/yr (~$9.25/yr)6.6 W x 8,760 hrs / 1,000

Which competing models share Revent RVLH50 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hampton Bay 1001357397 50 / 47 CFM 1.0 sones (-0.10) 8.1 CFM/W 3 in. diameter
Tech Drive TD-BF-13 50 / 47 CFM 1.0 sones (-0.10) 8.1 CFM/W 3 in. diameter
VENTECHLATION BPT12-13E 50 / 47 CFM 1.0 sones (-0.10) 8.1 CFM/W 3 in. diameter
Revent RVL50 50 / 47 CFM 1.1 sones (Same) 7.6 CFM/W 4 in. diameter
Commercial Electric BF1103 50 / 46.8 CFM 1.0 sones (-0.10) 5.2 CFM/W 3 in. diameter

How much airflow margin does Revent RVLH50 give your bath?

Run a quick local room-volume check for Revent RVLH50 by entering square footage and ceiling height to spot under-vented steam risks early.

What plumbing or duct constraints rule out Revent RVLH50?

Compare where Revent RVLH50 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Homeowner profile: Bathroom floor <= 47 sq ft with 8-ft ceilings (41 sq ft at 9-ft height)
  • Suited to: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Revent RVLH50?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Revent RVLH50.

Can Revent RVLH50 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Revent RVLH50 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Revent RVLH50 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Revent RVLH50 lacks adequate reserve.

How does Revent RVLH50 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Revent RVLH50 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Revent RVLH50 quiet enough for a primary bedroom bathroom?

At 1.1 sones, Revent RVLH50 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Revent RVLH50 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Revent RVLH50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Revent RVLH50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Revent RVLH50?

Revent RVLH50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Revent RVLH50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Revent RVLH50's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories