Skip to main content
Grant Estimator

Tech Drive TD-BF-13 Exhaust Fan Specifications

ENERGY STAR PD #4439151 · Bathroom/Utility Room · Qualified 2025-06-06
Verified Specification Summary

Certified by EPA ENERGY STAR, Tech Drive TD-BF-13 delivers 50 CFM free-air (47 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 8.1 CFM/W efficacy, clearing residential IRC M1505 sizing up to 47 sq ft (8-ft height) or 41 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Tech Drive TD-BF-13 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 47 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
8.1 CFM/W (#338/1,145)
Static Retention
94.0% @ 0.25"
Motor Draw
6.2 W (2.3 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Tech Drive TD-BF-13 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 47 CFM out of 50 CFM (94.0% retention, 6.3 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Tech Drive's 27-unit lineup, TD-BF-13 (series: TD) carries PD #4439151 dating to 2025-06-06. Lighting kit: No. At 8.1 CFM/W (#338 of 1,145, top 30.7% of 1,145 rated models, more efficient than 69.3% of rated models, 3.4 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 6.2 watts, about 2.3 kWh/yr (~$0.37/yr at $0.16/kWh) for 1 hr/day shower timers or 54.3 kWh/yr (~$8.69/yr) continuously. Closest competing matches include Hampton Bay 1001357397 (50.0 CFM) and VENTECHLATION BPT12-13E (50.0 CFM).

How noisy is Tech Drive TD-BF-13 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Tech Drive TD-BF-13 measures 1.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why does rigid 3 in. diameter ducting protect Tech Drive TD-BF-13 airflow?

Connecting Tech Drive TD-BF-13 through rigid 3 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Tech Drive TD-BF-13 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Tech Drive TD-BF-13 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Tech Drive (27 models) ENERGY STAR Certified Partner
Model Number & Series TD-BF-13 / TD PD ID 4439151 (Qualified 2025-06-06)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (47 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Tech Drive TD-BF-13?

Calculated coverage metrics translate Tech Drive TD-BF-13 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Tech Drive TD-BF-13
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 47 sq ft1 CFM/sq ft @ 47 CFM
Tall Bath (9-ft Ceiling)Up to 41 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)2.3 kWh/yr (~$0.37/yr)6.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.254.3 kWh/yr (~$8.69/yr)6.2 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Tech Drive TD-BF-13?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hampton Bay 1001357397 50 / 47 CFM 1.0 sones (Same) 8.1 CFM/W 3 in. diameter
VENTECHLATION BPT12-13E 50 / 47 CFM 1.0 sones (Same) 8.1 CFM/W 3 in. diameter
Revent RVL50 50 / 47 CFM 1.1 sones (+0.10) 7.6 CFM/W 4 in. diameter
Revent RVLH50 50 / 47 CFM 1.1 sones (+0.10) 7.6 CFM/W 4 in. diameter
Revent RVS50 50 / 50 CFM 1.0 sones (Same) 9.1 CFM/W 4 in. diameter

Does Tech Drive TD-BF-13 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Tech Drive TD-BF-13 percentage capacity without sending data.

Does Tech Drive TD-BF-13 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Tech Drive TD-BF-13 for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Strong scenario: Supplementary continuous trickle ventilation
  • Best application: Collar pairs with 3 in. diameter duct straight outdoors

Which homeowner questions come up most for Tech Drive TD-BF-13?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Tech Drive TD-BF-13.

What acoustic sone tier does Tech Drive TD-BF-13 occupy in EPA filings?

With 1.0 sones at 0.1 in. w.g., Tech Drive TD-BF-13 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Tech Drive TD-BF-13 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Tech Drive TD-BF-13 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Tech Drive TD-BF-13 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Tech Drive TD-BF-13's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Tech Drive TD-BF-13?

Tech Drive TD-BF-13 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Tech Drive TD-BF-13's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Tech Drive TD-BF-13's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Tech Drive TD-BF-13 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Tech Drive TD-BF-13 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Tech Drive TD-BF-13 in a bathroom remodel?

Avoid specifying Tech Drive TD-BF-13 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Tech Drive TD-BF-13 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Tech Drive TD-BF-13 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 3 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories