Rated for 50 CFM open-air (43.4 CFM at 0.25 in. w.g.), VOTATEC VO-FN4W18-AC-50 registers #265 of 607 in quietness (1.0 sones) and delivers 3.0 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 43 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VOTATEC VO-FN4W18-AC-50 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 43.4 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 86.8% @ 0.25"
- Motor Draw
- 16.7 W (6.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does VOTATEC VO-FN4W18-AC-50 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 43.4 CFM out of 50 CFM (86.8% retention, 0.9 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: VOTATEC registers 4 certified models, with SKU VO-FN4W18-AC-50 (series: VO-FN4W18-AC-50) (PD #4471332) certified since 2025-07-11. Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include HomeWerks Worldwide 7140-50 (50.0 CFM) and HomeWerks Worldwide 7140-50-G3 (50.0 CFM).
How does VOTATEC VO-FN4W18-AC-50 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against VOTATEC VO-FN4W18-AC-50 (1.0 sones).
How do flex elbows choke VOTATEC VO-FN4W18-AC-50 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps VOTATEC VO-FN4W18-AC-50 moving full rated CFM.
Does VOTATEC VO-FN4W18-AC-50 meet residential exhaust fan code specs?
Inspect VOTATEC VO-FN4W18-AC-50 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VOTATEC (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VO-FN4W18-AC-50 / VO-FN4W18-AC-50 | PD ID 4471332 (Qualified 2025-07-11) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (43.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match VOTATEC VO-FN4W18-AC-50 airflow output?
Annual electricity figures and room square-footage ceilings below reflect VOTATEC VO-FN4W18-AC-50 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 43 sq ft | 1 CFM/sq ft @ 43.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 38 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |
Which competing models share VOTATEC VO-FN4W18-AC-50 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| HomeWerks Worldwide 7140-50 | 50 / 43.4 CFM | 1.0 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7140-50-G3 | 50 / 36.1 CFM | 1.0 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| Commercial Electric BPT13-12EN | 50 / 49.3 CFM | 1.0 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| MaxLite EBF17-50-1-W | 50 / 49.3 CFM | 1.0 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| Tech Drive FA-BF-01-L | 50 / 45.1 CFM | 1.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |
How much airflow margin does VOTATEC VO-FN4W18-AC-50 give your bath?
Run a quick local room-volume check for VOTATEC VO-FN4W18-AC-50 by entering square footage and ceiling height to spot under-vented steam risks early.
Does VOTATEC VO-FN4W18-AC-50 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying VOTATEC VO-FN4W18-AC-50 for your remodel.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 43 sq ft with 8-ft ceilings (38 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about VOTATEC VO-FN4W18-AC-50?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to VOTATEC VO-FN4W18-AC-50.
Who should NOT install VOTATEC VO-FN4W18-AC-50 in a bathroom remodel?
Avoid specifying VOTATEC VO-FN4W18-AC-50 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut VOTATEC VO-FN4W18-AC-50 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, VOTATEC VO-FN4W18-AC-50 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does VOTATEC VO-FN4W18-AC-50 occupy in EPA filings?
With 1.0 sones at 0.1 in. w.g., VOTATEC VO-FN4W18-AC-50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does VOTATEC VO-FN4W18-AC-50 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, VOTATEC VO-FN4W18-AC-50 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can VOTATEC VO-FN4W18-AC-50 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VOTATEC VO-FN4W18-AC-50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VOTATEC VO-FN4W18-AC-50?
VOTATEC VO-FN4W18-AC-50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VOTATEC VO-FN4W18-AC-50's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VOTATEC VO-FN4W18-AC-50's safe coverage footprint from 50 sq ft to 44 sq ft.
Does VOTATEC VO-FN4W18-AC-50 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), VOTATEC VO-FN4W18-AC-50 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)