Skip to main content
Grant Estimator

Ortech ODC-1109 Exhaust Fan Specifications

ENERGY STAR PD #3892186 · Bathroom/Utility Room · Qualified 2024-12-20
Verified Specification Summary

Certified by EPA ENERGY STAR, Ortech ODC-1109 delivers 116 CFM free-air (106.8 CFM at 0.25 in. w.g.) and registers #357 of 607 in quietness (1.1 sones) and delivers 4.7 CFM/W efficacy, clearing residential IRC M1505 sizing up to 106 sq ft (8-ft height) or 94 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODC-1109 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
116 / 106.8 CFM
Noise @ 0.1"
1.1 sones (#357/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
92.1% @ 0.25"
Motor Draw
24.7 W (9.0 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Ortech ODC-1109 vs. 1,145-Model ENERGY STAR Benchmarks show?

Moderate audible output of 1.1 sones (#357 of 607 rated models, 0.10 sones louder than the 1.00 sones median), giving noticeable airflow feedback for guest baths.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 106.8 CFM out of 116 CFM (92.1% retention, 4.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #3892186 verifies ODC-1109 (series: ODC-1109) under Ortech (27 listed models, qualified 2024-12-20). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 24.7 watts, about 9.0 kWh/yr (~$1.44/yr at $0.16/kWh) for 1 hr/day shower timers or 216.4 kWh/yr (~$34.62/yr) continuously. Closest competing matches include Loren Cook Company GC-222 (115.0 CFM) and Aria QBV01100 (110.0 CFM).

How noisy is Ortech ODC-1109 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODC-1109 measures 1.1 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.1 sone: 1.1 sones (62nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.1 sone: 1.1 sones (P62)

Why does rigid 4 in. diameter ducting protect Ortech ODC-1109 airflow?

Connecting Ortech ODC-1109 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Ortech ODC-1109 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODC-1109 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Ortech (27 models) ENERGY STAR Certified Partner
Model Number & Series ODC-1109 / ODC-1109 PD ID 3892186 (Qualified 2024-12-20)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (106.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) NO (1.1 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What room sizes and annual power draw fit Ortech ODC-1109?

Calculated coverage metrics translate Ortech ODC-1109 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Ortech ODC-1109
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 106 sq ft1 CFM/sq ft @ 106.8 CFM
Tall Bath (9-ft Ceiling)Up to 94 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 56 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)9.0 kWh/yr (~$1.44/yr)24.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2216.4 kWh/yr (~$34.62/yr)24.7 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Ortech ODC-1109?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Loren Cook Company GC-222 115 / 85 CFM 1.2 sones (+0.10) 4.8 CFM/W 4.5 x 6 in. rectangular
Aria QBV01100 110 / 101.5 CFM 1.1 sones (Same) 4.5 CFM/W 4 in. diameter
Good Housekeeping 84006 110 / 101.5 CFM 1.1 sones (Same) 4.5 CFM/W 4 in. diameter
AERO PURE ABF110G16W 110 / 83.6 CFM 1.1 sones (Same) 4.4 CFM/W 4 in. diameter
AUPU AV11A3 110 / 83.6 CFM 1.1 sones (Same) 4.4 CFM/W 4 in. diameter

Does Ortech ODC-1109 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODC-1109 percentage capacity without sending data.

What plumbing or duct constraints rule out Ortech ODC-1109?

Compare where Ortech ODC-1109 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 56 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 106.8 CFM net static output
  • Suited to: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Ortech ODC-1109?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODC-1109.

How does Ortech ODC-1109 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Ortech ODC-1109 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Is Ortech ODC-1109 quiet enough for a primary bedroom bathroom?

At 1.1 sones, Ortech ODC-1109 produces audible mechanical sound suited better to utility baths or half-baths than quiet primary suites; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Ortech ODC-1109 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Ortech ODC-1109 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODC-1109's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Ortech ODC-1109?

Ortech ODC-1109 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Ortech ODC-1109's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODC-1109's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Ortech ODC-1109 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Ortech ODC-1109 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Ortech ODC-1109 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Ortech ODC-1109 lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories