In EPA dataset 8dv7-nngq, HomeWerks Worldwide 7140-50-G3 tests at 50 CFM free discharge (36.1 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 3.0 CFM/W efficacy, meeting residential IRC M1505 sizing up to 36 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside HomeWerks Worldwide 7140-50-G3 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 36.1 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 3.0 CFM/W (#1,105/1,145)
- Static Retention
- 72.2% @ 0.25"
- Motor Draw
- 16.7 W (6.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does HomeWerks Worldwide 7140-50-G3 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 36.1 CFM at 0.25 in. w.g. (72.2% retention, 15.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms HomeWerks Worldwide 7140-50-G3 (series: 7140-50-G3) under PD #4697714 (31 models registered, 2026-09-02). Lighting kit: No. At 3.0 CFM/W (#1,105 of 1,145, below median tier among 1,145 rated models; more efficient than 1.2% of rated models, 1.7 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include VOTATEC VO-FN4W18-AC-50 (50.0 CFM) and Commercial Electric BPT13-12EN (50.0 CFM).
Does HomeWerks Worldwide 7140-50-G3 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with HomeWerks Worldwide 7140-50-G3 at 1.0 sones.
Why avoid unvented attic termination with HomeWerks Worldwide 7140-50-G3?
Under ASHRAE 62.2 best practice, HomeWerks Worldwide 7140-50-G3 needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern HomeWerks Worldwide 7140-50-G3?
Before cutting ceiling drywall or sizing attic transitions for HomeWerks Worldwide 7140-50-G3, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | HomeWerks Worldwide (31 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 7140-50-G3 / 7140-50-G3 | PD ID 4697714 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (36.1 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit HomeWerks Worldwide 7140-50-G3?
Bathroom ventilation sizing below maps HomeWerks Worldwide 7140-50-G3 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 36 sq ft | 1 CFM/sq ft @ 36.1 CFM |
| Tall Bath (9-ft Ceiling) | Up to 32 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |
What peer models sit nearest HomeWerks Worldwide 7140-50-G3 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to HomeWerks Worldwide 7140-50-G3.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| VOTATEC VO-FN4W18-AC-50 | 50 / 43.4 CFM | 1.0 sones (Same) | 3.0 CFM/W | 4 in. diameter |
| Commercial Electric BPT13-12EN | 50 / 49.3 CFM | 1.0 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| MaxLite EBF17-50-1-W | 50 / 49.3 CFM | 1.0 sones (Same) | 3.7 CFM/W | 3 in. diameter |
| Tech Drive FA-BF-01-L | 50 / 45.1 CFM | 1.0 sones (Same) | 3.8 CFM/W | 3 in. diameter |
| Broan-Nutone BE6 | 60 / 52.6 CFM | 0.9 sones (-0.10) | 3.6 CFM/W | 4 in. diameter |
What percentage of room demand does HomeWerks Worldwide 7140-50-G3 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against HomeWerks Worldwide 7140-50-G3 tested delivery.
Does HomeWerks Worldwide 7140-50-G3 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying HomeWerks Worldwide 7140-50-G3 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 36.1 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 1.0 sones up to 36 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for HomeWerks Worldwide 7140-50-G3?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing HomeWerks Worldwide 7140-50-G3.
How many kWh per year does HomeWerks Worldwide 7140-50-G3 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, HomeWerks Worldwide 7140-50-G3 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can HomeWerks Worldwide 7140-50-G3 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from HomeWerks Worldwide 7140-50-G3's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing HomeWerks Worldwide 7140-50-G3?
HomeWerks Worldwide 7140-50-G3 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change HomeWerks Worldwide 7140-50-G3's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing HomeWerks Worldwide 7140-50-G3's safe coverage footprint from 50 sq ft to 44 sq ft.
Does HomeWerks Worldwide 7140-50-G3 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), HomeWerks Worldwide 7140-50-G3 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install HomeWerks Worldwide 7140-50-G3 in a bathroom remodel?
Avoid specifying HomeWerks Worldwide 7140-50-G3 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut HomeWerks Worldwide 7140-50-G3 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, HomeWerks Worldwide 7140-50-G3 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does HomeWerks Worldwide 7140-50-G3 occupy in EPA filings?
With 1.0 sones at 0.1 in. w.g., HomeWerks Worldwide 7140-50-G3 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)