Rated for 60 CFM open-air (52.6 CFM at 0.25 in. w.g.), Broan-Nutone BE6 registers #239 of 607 in quietness (0.9 sones) and delivers 3.6 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 52 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BE6 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 60 / 52.6 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 87.7% @ 0.25"
- Motor Draw
- 16.7 W (6.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone BE6 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 52.6 CFM out of 60 CFM (87.7% retention, equal to the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3624221 verifies BE6 (series: ROOMSIDE) under Broan-Nutone (48 listed models, qualified 2024-06-21). Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Commercial Electric BPT13-12EN (50.0 CFM) and MaxLite EBF17-50-1-W (50.0 CFM).
How does Broan-Nutone BE6 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan-Nutone BE6 (0.9 sones).
How do flex elbows choke Broan-Nutone BE6 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan-Nutone BE6 moving full rated CFM.
Does Broan-Nutone BE6 meet residential exhaust fan code specs?
Inspect Broan-Nutone BE6 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BE6 / ROOMSIDE | PD ID 3624221 (Qualified 2024-06-21) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (52.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan-Nutone BE6 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan-Nutone BE6 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 52 sq ft | 1 CFM/sq ft @ 52.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |
Which competing models share Broan-Nutone BE6 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Commercial Electric BPT13-12EN | 50 / 49.3 CFM | 1.0 sones (+0.10) | 3.7 CFM/W | 3 in. diameter |
| MaxLite EBF17-50-1-W | 50 / 49.3 CFM | 1.0 sones (+0.10) | 3.7 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7105-10 | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7105-10-MB | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| Nektra 33003851 | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
How much airflow margin does Broan-Nutone BE6 give your bath?
Run a quick local room-volume check for Broan-Nutone BE6 by entering square footage and ceiling height to spot under-vented steam risks early.
When does Broan-Nutone BE6 fail to fit a residential bathroom?
Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Broan-Nutone BE6.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Recommended when: Bathroom floor <= 52 sq ft with 8-ft ceilings (46 sq ft at 9-ft height)
- Target scenario: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Broan-Nutone BE6?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan-Nutone BE6.
Will Broan-Nutone BE6 disturb adjacent bedrooms during night use?
Acoustic measurement places Broan-Nutone BE6 at 0.9 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.
Does running Broan-Nutone BE6 continuously spike household electricity use?
Using ENERGY STAR airflow verification, 24/7 operation of Broan-Nutone BE6 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.
Can Broan-Nutone BE6 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BE6's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone BE6?
Broan-Nutone BE6 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone BE6's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BE6's safe coverage footprint from 50 sq ft to 44 sq ft.
Is Broan-Nutone BE6 code-compliant for residential exhaust under IRC M1505?
Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BE6 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.
Which bathroom layouts should pick a larger blower than Broan-Nutone BE6?
Do not force Broan-Nutone BE6 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.
How much airflow does Broan-Nutone BE6 retain under real duct backpressure?
Under HVI 0.25 in. w.g. static pressure testing, Broan-Nutone BE6 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)