In EPA dataset 8dv7-nngq, Broan-Nutone BE6 = BEH with BE6F tests at 60 CFM free discharge (52.6 CFM at 0.25 in. w.g.) and registers #239 of 607 in quietness (0.9 sones) and delivers 3.6 CFM/W efficacy, meeting residential IRC M1505 sizing up to 52 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BE6 = BEH with BE6F Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 60 / 52.6 CFM
- Noise @ 0.1"
- 0.9 sones (#239/607)
- Efficacy Rank
- 3.6 CFM/W (#1,017/1,145)
- Static Retention
- 87.7% @ 0.25"
- Motor Draw
- 16.7 W (6.1 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan-Nutone BE6 = BEH with BE6F vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 52.6 CFM out of 60 CFM (87.7% retention, equal to the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #3629333 verifies BE6 = BEH with BE6F (series: ROOMSIDE) under Broan-Nutone (48 listed models, qualified 2024-07-12). Lighting kit: No. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Commercial Electric BPT13-12EN (50.0 CFM) and MaxLite EBF17-50-1-W (50.0 CFM).
Does Broan-Nutone BE6 = BEH with BE6F fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan-Nutone BE6 = BEH with BE6F at 0.9 sones.
Why avoid unvented attic termination with Broan-Nutone BE6 = BEH with BE6F?
Under ASHRAE 62.2 best practice, Broan-Nutone BE6 = BEH with BE6F needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Broan-Nutone BE6 = BEH with BE6F?
Before cutting ceiling drywall or sizing attic transitions for Broan-Nutone BE6 = BEH with BE6F, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan-Nutone (48 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BE6 = BEH with BE6F / ROOMSIDE | PD ID 3629333 (Qualified 2024-07-12) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (52.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.9 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Broan-Nutone BE6 = BEH with BE6F?
Bathroom ventilation sizing below maps Broan-Nutone BE6 = BEH with BE6F motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 52 sq ft | 1 CFM/sq ft @ 52.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 46 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.1 kWh/yr (~$0.98/yr) | 16.7 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 146.3 kWh/yr (~$23.41/yr) | 16.7 W x 8,760 hrs / 1,000 |
What peer models sit nearest Broan-Nutone BE6 = BEH with BE6F in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan-Nutone BE6 = BEH with BE6F.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Commercial Electric BPT13-12EN | 50 / 49.3 CFM | 1.0 sones (+0.10) | 3.7 CFM/W | 3 in. diameter |
| MaxLite EBF17-50-1-W | 50 / 49.3 CFM | 1.0 sones (+0.10) | 3.7 CFM/W | 3 in. diameter |
| HomeWerks Worldwide 7105-10 | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7105-10-MB | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| Nektra 33003851 | 70 / 55.7 CFM | 1.0 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
What percentage of room demand does Broan-Nutone BE6 = BEH with BE6F cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan-Nutone BE6 = BEH with BE6F tested delivery.
Who should not install Broan-Nutone BE6 = BEH with BE6F in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan-Nutone BE6 = BEH with BE6F for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 52.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 0.9 sones up to 52 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for Broan-Nutone BE6 = BEH with BE6F?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan-Nutone BE6 = BEH with BE6F.
How does Broan-Nutone BE6 = BEH with BE6F sound output compare to noisy contractor-grade fans?
Rated at 0.9 sones, Broan-Nutone BE6 = BEH with BE6F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define Broan-Nutone BE6 = BEH with BE6F?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can Broan-Nutone BE6 = BEH with BE6F pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BE6 = BEH with BE6F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan-Nutone BE6 = BEH with BE6F?
Broan-Nutone BE6 = BEH with BE6F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan-Nutone BE6 = BEH with BE6F's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BE6 = BEH with BE6F's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan-Nutone BE6 = BEH with BE6F satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BE6 = BEH with BE6F clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is Broan-Nutone BE6 = BEH with BE6F undersized or poorly matched for a bath renovation?
Skip Broan-Nutone BE6 = BEH with BE6F if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check Broan-Nutone BE6 = BEH with BE6F CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan-Nutone BE6 = BEH with BE6F registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)