Skip to main content
Grant Estimator

Broan-Nutone BEL6 = BELH with BEL6F Exhaust Fan Specifications

ENERGY STAR PD #3701869 · Bathroom/Utility Room · Qualified 2024-10-11
Verified Specification Summary

Homeowners specifying Broan-Nutone BEL6 = BELH with BEL6F gain 60 CFM at 0.1 in. w.g. (52.6 CFM at 0.25 in. w.g.) where it registers #239 of 607 in quietness (0.9 sones) and delivers 3.6 CFM/W efficacy, venting bathrooms up to 52 sq ft cleanly through 4 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BEL6 = BELH with BEL6F Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
60 / 52.6 CFM
Noise @ 0.1"
0.9 sones (#239/607)
Efficacy Rank
3.6 CFM/W (#1,017/1,145)
Static Retention
87.7% @ 0.25"
Motor Draw
16.7 W (6.1 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone BEL6 = BELH with BEL6F vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.9 sones (#239 of 607 rated models, quietest 43.5% of 607 rated models, quieter than 56.5% of rated models, 0.10 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 52.6 CFM out of 60 CFM (87.7% retention, equal to the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places BEL6 = BELH with BEL6F (series: ROOMSIDE) (PD #3701869) among 48 Broan-Nutone entries qualified through 2024-10-11. Lighting kit: Yes. At 3.6 CFM/W (#1,017 of 1,145, below median tier among 1,145 rated models; more efficient than 9.4% of rated models, 1.1 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 16.7 watts, about 6.1 kWh/yr (~$0.98/yr at $0.16/kWh) for 1 hr/day shower timers or 146.3 kWh/yr (~$23.41/yr) continuously. Closest competing matches include Commercial Electric BPT13-12EN (50.0 CFM) and MaxLite EBF17-50-1-W (50.0 CFM).

What acoustic percentile does Broan-Nutone BEL6 = BELH with BEL6F occupy among 1,145 bath blowers?

Inspect how Broan-Nutone BEL6 = BELH with BEL6F positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.9 sone: 0.9 sones (43rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.9 sone: 0.9 sones (P43)

Which exterior damper path suits Broan-Nutone BEL6 = BELH with BEL6F best?

Exterior roof or wall damper termination paired with insulated 4 in. diameter metal pipe prevents condensation buildup around Broan-Nutone BEL6 = BELH with BEL6F housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan-Nutone BEL6 = BELH with BEL6F acoustic and static metrics stand?

Compare Broan-Nutone BEL6 = BELH with BEL6F published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series BEL6 = BELH with BEL6F / ROOMSIDE PD ID 3701869 (Qualified 2024-10-11)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (52.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.9 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Broan-Nutone BEL6 = BELH with BEL6F handle taller ceilings or walk-in tub steam?

Evaluate how Broan-Nutone BEL6 = BELH with BEL6F scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan-Nutone BEL6 = BELH with BEL6F
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 52 sq ft1 CFM/sq ft @ 52.6 CFM
Tall Bath (9-ft Ceiling)Up to 46 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.1 kWh/yr (~$0.98/yr)16.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2146.3 kWh/yr (~$23.41/yr)16.7 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan-Nutone BEL6 = BELH with BEL6F?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Commercial Electric BPT13-12EN 50 / 49.3 CFM 1.0 sones (+0.10) 3.7 CFM/W 3 in. diameter
MaxLite EBF17-50-1-W 50 / 49.3 CFM 1.0 sones (+0.10) 3.7 CFM/W 3 in. diameter
HomeWerks Worldwide 7105-10 70 / 55.7 CFM 1.0 sones (+0.10) 3.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7105-10-MB 70 / 55.7 CFM 1.0 sones (+0.10) 3.4 CFM/W 4 in. diameter
Nektra 33003851 70 / 55.7 CFM 1.0 sones (+0.10) 3.4 CFM/W 4 in. diameter

Is Broan-Nutone BEL6 = BELH with BEL6F sized right for your shower or tub room?

Check whether Broan-Nutone BEL6 = BELH with BEL6F clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Which bath layouts should avoid specifying Broan-Nutone BEL6 = BELH with BEL6F?

Match Broan-Nutone BEL6 = BELH with BEL6F directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Best for: Moisture load fits 52.6 CFM net static output
  • Optimal use: Collar pairs with 4 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan-Nutone BEL6 = BELH with BEL6F?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan-Nutone BEL6 = BELH with BEL6F.

What does Broan-Nutone BEL6 = BELH with BEL6F cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running Broan-Nutone BEL6 = BELH with BEL6F 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can Broan-Nutone BEL6 = BELH with BEL6F pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BEL6 = BELH with BEL6F's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone BEL6 = BELH with BEL6F?

Broan-Nutone BEL6 = BELH with BEL6F features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone BEL6 = BELH with BEL6F's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BEL6 = BELH with BEL6F's safe coverage footprint from 50 sq ft to 44 sq ft.

What bathroom square footage can Broan-Nutone BEL6 = BELH with BEL6F ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BEL6 = BELH with BEL6F covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does Broan-Nutone BEL6 = BELH with BEL6F run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan-Nutone BEL6 = BELH with BEL6F.

What happens to Broan-Nutone BEL6 = BELH with BEL6F CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, Broan-Nutone BEL6 = BELH with BEL6F moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does Broan-Nutone BEL6 = BELH with BEL6F sit on acoustic comfort for senior homeowners?

Measuring 0.9 sones, Broan-Nutone BEL6 = BELH with BEL6F operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories