In EPA dataset 8dv7-nngq, Delta PRO200 tests at 200 CFM free discharge (163.6 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 11.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 163 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta PRO200 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 200 / 163.6 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 11.4 CFM/W (#115/1,145)
- Static Retention
- 81.8% @ 0.25"
- Motor Draw
- 17.5 W (6.4 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Delta PRO200 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 200 CFM open-air to 163.6 CFM at 0.25 in. w.g. (81.8% retention, 5.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Manufacturer coverage places PRO200 (series: BreezPro) (PD #2249909) among 121 Delta entries qualified through 2015-10-01. Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.5 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 153.3 kWh/yr (~$24.53/yr) continuously. Closest competing matches include Panasonic FV-20VQ3 (190.0 CFM) and Best HBN223012SS (180.0 CFM).
Does Delta PRO200 fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta PRO200 at 1.0 sones.
Why avoid unvented attic termination with Delta PRO200?
Under ASHRAE 62.2 best practice, Delta PRO200 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern Delta PRO200?
Before cutting ceiling drywall or sizing attic transitions for Delta PRO200, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Delta (121 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PRO200 / BreezPro | PD ID 2249909 (Qualified 2015-10-01) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (163.6 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What daily runtime and room footprint suit Delta PRO200?
Bathroom ventilation sizing below maps Delta PRO200 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 163 sq ft | 1 CFM/sq ft @ 163.6 CFM |
| Tall Bath (9-ft Ceiling) | Up to 145 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 113 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.4 kWh/yr (~$1.02/yr) | 17.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 153.3 kWh/yr (~$24.53/yr) | 17.5 W x 8,760 hrs / 1,000 |
What peer models sit nearest Delta PRO200 in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta PRO200.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Panasonic FV-20VQ3 | 190 / 148.9 CFM | 0.9 sones (-0.10) | 4.6 CFM/W | 6 in. diameter |
| Best HBN223012SS | 180 / N/A CFM | 0.1 sones (-0.90) | 14.2 CFM/W | 10 in. diameter |
| Best HBN223612SS | 180 / N/A CFM | 0.1 sones (-0.90) | 14.2 CFM/W | 10 in. diameter |
| Best HBN224812SS | 180 / N/A CFM | 0.1 sones (-0.90) | 14.2 CFM/W | 10 in. diameter |
| Delta SMT150-200LED | 200 / 204.9 CFM | Unpublished | 10.3 CFM/W | 6 in. diameter |
What percentage of room demand does Delta PRO200 cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta PRO200 tested delivery.
Does Delta PRO200 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta PRO200 for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 163.6 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 1.0 sones up to 163 sq ft
- Best application: Paired with rigid galvanized 6 in. diameter transition
Where do official rules set limits for Delta PRO200?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta PRO200.
How many kWh per year does Delta PRO200 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Delta PRO200 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Delta PRO200 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta PRO200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Delta PRO200?
Delta PRO200 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Delta PRO200's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta PRO200's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Delta PRO200 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta PRO200 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Delta PRO200 in a bathroom remodel?
Avoid specifying Delta PRO200 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Delta PRO200 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta PRO200 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Delta PRO200 occupy in EPA filings?
With 1.0 sones at 0.1 in. w.g., Delta PRO200 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)