Verified Specification Summary

In EPA dataset 8dv7-nngq, Delta PRO200 tests at 200 CFM free discharge (163.6 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 11.4 CFM/W efficacy, meeting residential IRC M1505 sizing up to 163 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Delta PRO200 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
200 / 163.6 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
11.4 CFM/W (#115/1,145)
Static Retention
81.8% @ 0.25"
Motor Draw
17.5 W (6.4 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Delta PRO200 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 200 CFM open-air to 163.6 CFM at 0.25 in. w.g. (81.8% retention, 5.9 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Manufacturer coverage places PRO200 (series: BreezPro) (PD #2249909) among 121 Delta entries qualified through 2015-10-01. Lighting kit: No. At 11.4 CFM/W (#115 of 1,145, top 10.7% of 1,145 rated models, more efficient than 89.3% of rated models, 6.7 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 17.5 watts, about 6.4 kWh/yr (~$1.02/yr at $0.16/kWh) for 1 hr/day shower timers or 153.3 kWh/yr (~$24.53/yr) continuously. Closest competing matches include Panasonic FV-20VQ3 (190.0 CFM) and Best HBN223012SS (180.0 CFM).

Does Delta PRO200 fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Delta PRO200 at 1.0 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why avoid unvented attic termination with Delta PRO200?

Under ASHRAE 62.2 best practice, Delta PRO200 needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Delta PRO200?

Before cutting ceiling drywall or sizing attic transitions for Delta PRO200, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Delta (121 models) ENERGY STAR Certified Partner
Model Number & Series PRO200 / BreezPro PD ID 2249909 (Qualified 2015-10-01)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (163.6 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Delta PRO200?

Bathroom ventilation sizing below maps Delta PRO200 motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Delta PRO200
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 163 sq ft1 CFM/sq ft @ 163.6 CFM
Tall Bath (9-ft Ceiling)Up to 145 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 113 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.4 kWh/yr (~$1.02/yr)17.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2153.3 kWh/yr (~$24.53/yr)17.5 W x 8,760 hrs / 1,000

What peer models sit nearest Delta PRO200 in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Delta PRO200.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Panasonic FV-20VQ3 190 / 148.9 CFM 0.9 sones (-0.10) 4.6 CFM/W 6 in. diameter
Best HBN223012SS 180 / N/A CFM 0.1 sones (-0.90) 14.2 CFM/W 10 in. diameter
Best HBN223612SS 180 / N/A CFM 0.1 sones (-0.90) 14.2 CFM/W 10 in. diameter
Best HBN224812SS 180 / N/A CFM 0.1 sones (-0.90) 14.2 CFM/W 10 in. diameter
Delta SMT150-200LED 200 / 204.9 CFM Unpublished 10.3 CFM/W 6 in. diameter

What percentage of room demand does Delta PRO200 cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Delta PRO200 tested delivery.

Does Delta PRO200 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Delta PRO200 for your remodel.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 163.6 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Strong scenario: Target comfort around 1.0 sones up to 163 sq ft
  • Best application: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Delta PRO200?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Delta PRO200.

How many kWh per year does Delta PRO200 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Delta PRO200 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Delta PRO200 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Delta PRO200's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Delta PRO200?

Delta PRO200 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Delta PRO200's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Delta PRO200's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Delta PRO200 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Delta PRO200 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Delta PRO200 in a bathroom remodel?

Avoid specifying Delta PRO200 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Delta PRO200 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Delta PRO200 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Delta PRO200 occupy in EPA filings?

With 1.0 sones at 0.1 in. w.g., Delta PRO200 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.