Skip to main content
Grant Estimator

Best HBN224812SS Exhaust Fan Specifications

ENERGY STAR PD #4005528 · Range Hood · Qualified 2025-03-21
Verified Specification Summary

Rated for 180 CFM open-air (unpublished 0.25 in. w.g. output), Best HBN224812SS registers #10 of 607 in quietness (0.1 sones) and delivers 14.2 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 180 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Best HBN224812SS Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
180 / N/A CFM
Noise @ 0.1"
0.1 sones (#10/607)
Efficacy Rank
14.2 CFM/W (#37/1,145)
Static Retention
0.1" test only
Motor Draw
12.7 W (4.6 kWh/yr)
Duct & Tier
10 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Best HBN224812SS vs. 1,145-Model ENERGY STAR Benchmarks show?

Library-quiet acoustic profile at 0.1 sones (#10 of 607 rated models, quietest 2.8% of 607 rated models, quieter than 97.2% of rated models, 0.90 sones quieter than the 1.00 sones median), ideal beside senior bedrooms.

Free-discharge delivery reaches 180 CFM (#69 of 1,145 certified models) via a 10 in. diameter exhaust collar without published 0.25 in. w.g. test points. Keep 10 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #4005528 verifies HBN224812SS (series: RANGE HOOD) under Best (17 listed models, qualified 2025-03-21). Lighting kit: Yes. At 14.2 CFM/W (#37 of 1,145, top 3.8% of 1,145 rated models, more efficient than 96.2% of rated models, 9.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 12.7 watts, about 4.6 kWh/yr (~$0.74/yr at $0.16/kWh) for 1 hr/day shower timers or 111.3 kWh/yr (~$17.81/yr) continuously. Closest competing matches include Best HBN223012SS (180.0 CFM) and Best HBN223612SS (180.0 CFM).

How does Best HBN224812SS acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Best HBN224812SS (0.1 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.1 sone: 0.1 sones (3rd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.1 sone: 0.1 sones (P3)

How do flex elbows choke Best HBN224812SS at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 10 in. diameter metal pipe keeps Best HBN224812SS moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Best HBN224812SS meet residential exhaust fan code specs?

Inspect Best HBN224812SS mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Best (17 models) ENERGY STAR Certified Partner
Model Number & Series HBN224812SS / RANGE HOOD PD ID 4005528 (Qualified 2025-03-21)
Duct Connection 10 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (180 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.1 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Which bathroom duties match Best HBN224812SS airflow output?

Annual electricity figures and room square-footage ceilings below reflect Best HBN224812SS tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Best HBN224812SS
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 180 sq ft1 CFM/sq ft @ 180 CFM
Tall Bath (9-ft Ceiling)Up to 160 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 130 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.6 kWh/yr (~$0.74/yr)12.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2111.3 kWh/yr (~$17.81/yr)12.7 W x 8,760 hrs / 1,000

Which competing models share Best HBN224812SS airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Best HBN223012SS 180 / N/A CFM 0.1 sones (Same) 14.2 CFM/W 10 in. diameter
Best HBN223612SS 180 / N/A CFM 0.1 sones (Same) 14.2 CFM/W 10 in. diameter
Best HBN536212SS 200 / N/A CFM 0.0 sones (-0.10) 16.6 CFM/W 10 in. diameter
Best HBN536912SS 200 / N/A CFM 0.0 sones (-0.10) 16.6 CFM/W 10 in. diameter
Best HBN542912SS 200 / N/A CFM 0.0 sones (-0.10) 16.6 CFM/W 10 in. diameter

How much airflow margin does Best HBN224812SS give your bath?

Run a quick local room-volume check for Best HBN224812SS by entering square footage and ceiling height to spot under-vented steam risks early.

Where should contractors skip Best HBN224812SS on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Best HBN224812SS carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Steam or walk-in tub room > 130 sq ft requiring +50 CFM boost
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Choose this if: Bathroom floor <= 180 sq ft with 8-ft ceilings (160 sq ft at 9-ft height)
  • Works well for: Exterior run uses smooth rigid metal matched to 10 in. diameter

What should homeowners verify first about Best HBN224812SS?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Best HBN224812SS.

Will long attic ducting choke Best HBN224812SS capacity?

Because static drag at 0.25 in. w.g. lowers Best HBN224812SS from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 10 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Best HBN224812SS compared with a standard 3.0 sone builder fan?

Tested at 0.1 sones, Best HBN224812SS operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Best HBN224812SS consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Best HBN224812SS draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Best HBN224812SS pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Best HBN224812SS's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Best HBN224812SS?

Best HBN224812SS features a 10 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Best HBN224812SS's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Best HBN224812SS's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Best HBN224812SS score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Best HBN224812SS delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Best HBN224812SS?

Rule out Best HBN224812SS when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories