Skip to main content
Grant Estimator

OREiN OL1700376 Exhaust Fan Specifications

ENERGY STAR PD #3417435 · Bathroom/Utility Room · Qualified 2024-02-16
Verified Specification Summary

Certified by EPA ENERGY STAR, OREiN OL1700376 delivers 160 CFM free-air (152 CFM at 0.25 in. w.g.) and registers #265 of 607 in quietness (1.0 sones) and delivers 4.8 CFM/W efficacy, clearing residential IRC M1505 sizing up to 152 sq ft (8-ft height) or 135 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside OREiN OL1700376 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
160 / 152 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
4.8 CFM/W (#534/1,145)
Static Retention
95.0% @ 0.25"
Motor Draw
33.3 W (12.2 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does OREiN OL1700376 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 152 CFM out of 160 CFM (95.0% retention, 7.3 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Brand catalog footprint: OREiN registers 1 certified model, with SKU OL1700376 (series: M071 160CFM OL17003-CCT-US) (PD #3417435) certified since 2024-02-16. Lighting kit: Yes. At 4.8 CFM/W (#534 of 1,145, top 47.5% of 1,145 rated models, more efficient than 52.5% of rated models, 0.1 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 33.3 watts, about 12.2 kWh/yr (~$1.95/yr at $0.16/kWh) for 1 hr/day shower timers or 291.7 kWh/yr (~$46.67/yr) continuously. Closest competing matches include Tech Drive TD-BF-19 (160.0 CFM) and VENTECHLATION VF-BF-06 (160.0 CFM).

How noisy is OREiN OL1700376 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while OREiN OL1700376 measures 1.0 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Why does rigid 6 in. diameter ducting protect OREiN OL1700376 airflow?

Connecting OREiN OL1700376 through rigid 6 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify OREiN OL1700376 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for OREiN OL1700376 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share OREiN (1 model) ENERGY STAR Certified Partner
Model Number & Series OL1700376 / M071 160CFM OL17003-CCT-US PD ID 3417435 (Qualified 2024-02-16)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (152 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit OREiN OL1700376?

Calculated coverage metrics translate OREiN OL1700376 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for OREiN OL1700376
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 152 sq ft1 CFM/sq ft @ 152 CFM
Tall Bath (9-ft Ceiling)Up to 135 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 102 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)12.2 kWh/yr (~$1.95/yr)33.3 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2291.7 kWh/yr (~$46.67/yr)33.3 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to OREiN OL1700376?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-19 160 / 138.2 CFM 1.0 sones (Same) 4.5 CFM/W 6 in. diameter
VENTECHLATION VF-BF-06 160 / 138.2 CFM 1.0 sones (Same) 4.5 CFM/W 6 in. diameter
Air King AK150LS 150 / 124.4 CFM 0.9 sones (-0.10) 4.5 CFM/W 6 in. diameter
Hampton Bay 7136-02 140 / 124.4 CFM 1.0 sones (Same) 3.9 CFM/W 6 in. diameter
HomeWerks Worldwide 7136-02HW 140 / 124.4 CFM 1.0 sones (Same) 3.9 CFM/W 6 in. diameter

Does OREiN OL1700376 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check OREiN OL1700376 percentage capacity without sending data.

Where should contractors skip OREiN OL1700376 on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for OREiN OL1700376 carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 102 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 152 CFM net static output
  • Works well for: Collar pairs with 6 in. diameter duct straight outdoors

Which homeowner questions come up most for OREiN OL1700376?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around OREiN OL1700376.

How loud is OREiN OL1700376 compared with a standard 3.0 sone builder fan?

Tested at 1.0 sones, OREiN OL1700376 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does OREiN OL1700376 consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, OREiN OL1700376 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can OREiN OL1700376 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from OREiN OL1700376's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing OREiN OL1700376?

OREiN OL1700376 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change OREiN OL1700376's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing OREiN OL1700376's safe coverage footprint from 50 sq ft to 44 sq ft.

How does OREiN OL1700376 score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), OREiN OL1700376 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify OREiN OL1700376?

Rule out OREiN OL1700376 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke OREiN OL1700376 capacity?

Because static drag at 0.25 in. w.g. lowers OREiN OL1700376 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories