Homeowners specifying VENTECHLATION VF-BF-06 gain 160 CFM at 0.1 in. w.g. (138.2 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 4.5 CFM/W efficacy, venting bathrooms up to 138 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION VF-BF-06 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 160 / 138.2 CFM
- Noise @ 0.1"
- 1.0 sones (#265/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 86.4% @ 0.25"
- Motor Draw
- 35.6 W (13.0 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does VENTECHLATION VF-BF-06 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 138.2 CFM out of 160 CFM (86.4% retention, 1.3 pts lower retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Brand catalog footprint: VENTECHLATION registers 12 certified models, with SKU VF-BF-06 (series: VF) (PD #4697574) certified since 2026-09-02. Lighting kit: No. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 35.6 watts, about 13.0 kWh/yr (~$2.08/yr at $0.16/kWh) for 1 hr/day shower timers or 311.9 kWh/yr (~$49.90/yr) continuously. Closest competing matches include Tech Drive TD-BF-19 (160.0 CFM) and OREiN OL1700376 (160.0 CFM).
What acoustic percentile does VENTECHLATION VF-BF-06 occupy among 1,145 bath blowers?
Inspect how VENTECHLATION VF-BF-06 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.
Which exterior damper path suits VENTECHLATION VF-BF-06 best?
Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around VENTECHLATION VF-BF-06 housings.
Where do VENTECHLATION VF-BF-06 acoustic and static metrics stand?
Compare VENTECHLATION VF-BF-06 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VF-BF-06 / VF | PD ID 4697574 (Qualified 2026-09-02) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (138.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (1.0 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Can VENTECHLATION VF-BF-06 handle taller ceilings or walk-in tub steam?
Evaluate how VENTECHLATION VF-BF-06 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 138 sq ft | 1 CFM/sq ft @ 138.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 122 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 88 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 13.0 kWh/yr (~$2.08/yr) | 35.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 311.9 kWh/yr (~$49.90/yr) | 35.6 W x 8,760 hrs / 1,000 |
Are quieter or higher-efficacy peers available near VENTECHLATION VF-BF-06?
Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-19 | 160 / 138.2 CFM | 1.0 sones (Same) | 4.5 CFM/W | 6 in. diameter |
| OREiN OL1700376 | 160 / 152 CFM | 1.0 sones (Same) | 4.8 CFM/W | 6 in. diameter |
| Air King AK150LS | 150 / 124.4 CFM | 0.9 sones (-0.10) | 4.5 CFM/W | 6 in. diameter |
| Hampton Bay 7136-02 | 140 / 124.4 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| HomeWerks Worldwide 7136-02HW | 140 / 124.4 CFM | 1.0 sones (Same) | 3.9 CFM/W | 6 in. diameter |
Is VENTECHLATION VF-BF-06 sized right for your shower or tub room?
Check whether VENTECHLATION VF-BF-06 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.
Does VENTECHLATION VF-BF-06 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying VENTECHLATION VF-BF-06 for your remodel.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 88 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Moisture load fits 138.2 CFM net static output
- Best application: Collar pairs with 6 in. diameter duct straight outdoors
Which code checks and cost facts matter for VENTECHLATION VF-BF-06?
Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to VENTECHLATION VF-BF-06.
Who should NOT install VENTECHLATION VF-BF-06 in a bathroom remodel?
Avoid specifying VENTECHLATION VF-BF-06 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut VENTECHLATION VF-BF-06 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, VENTECHLATION VF-BF-06 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 6 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does VENTECHLATION VF-BF-06 occupy in EPA filings?
With 1.0 sones at 0.1 in. w.g., VENTECHLATION VF-BF-06 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does VENTECHLATION VF-BF-06 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, VENTECHLATION VF-BF-06 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can VENTECHLATION VF-BF-06 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION VF-BF-06's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION VF-BF-06?
VENTECHLATION VF-BF-06 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION VF-BF-06's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION VF-BF-06's safe coverage footprint from 50 sq ft to 44 sq ft.
Does VENTECHLATION VF-BF-06 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION VF-BF-06 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)