Commercial Electric BPT13-12EN Exhaust Fan Specifications

ENERGY STAR PD #4515516 · Bathroom/Utility Room · Qualified 2025-11-21
Verified Specification Summary

The Commercial Electric BPT13-12EN (BPT13) moves 50 CFM at 0.1 in. w.g. (49.3 CFM at 0.25 in. w.g.), registers #265 of 607 in quietness (1.0 sones), and delivers 3.7 CFM/W efficacy, sizing bathrooms up to 49 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BPT13-12EN Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
50 / 49.3 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
3.7 CFM/W (#987/1,145)
Static Retention
98.6% @ 0.25"
Motor Draw
13.5 W (4.9 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Commercial Electric BPT13-12EN vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 49.3 CFM out of 50 CFM (98.6% retention, 10.9 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Commercial Electric registers 15 certified models, with SKU BPT13-12EN (series: BPT13) (PD #4515516) certified since 2025-11-21. Lighting kit: No. At 3.7 CFM/W (#987 of 1,145, below median tier among 1,145 rated models; more efficient than 11.3% of rated models, 1.0 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 13.5 watts, about 4.9 kWh/yr (~$0.78/yr at $0.16/kWh) for 1 hr/day shower timers or 118.3 kWh/yr (~$18.93/yr) continuously. Closest competing matches include MaxLite EBF17-50-1-W (50.0 CFM) and Tech Drive FA-BF-01-L (50.0 CFM).

Where does Commercial Electric BPT13-12EN sit on the 1,145-model ENERGY STAR sone curve?

Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 1.0 sones against all 1,145 EPA listings.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

How does duct geometry alter Commercial Electric BPT13-12EN static pressure?

Smooth 3 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Which certified test ratings apply to Commercial Electric BPT13-12EN?

Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Commercial Electric BPT13-12EN alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Commercial Electric (15 models) ENERGY STAR Certified Partner
Model Number & Series BPT13-12EN / BPT13 PD ID 4515516 (Qualified 2025-11-21)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (49.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How much bathroom area can Commercial Electric BPT13-12EN ventilate safely?

Sizing outputs below convert Commercial Electric BPT13-12EN tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.

Bathroom sizing limits and annual kWh draw for Commercial Electric BPT13-12EN
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 49 sq ft1 CFM/sq ft @ 49.3 CFM
Tall Bath (9-ft Ceiling)Up to 43 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.9 kWh/yr (~$0.78/yr)13.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2118.3 kWh/yr (~$18.93/yr)13.5 W x 8,760 hrs / 1,000

Which ENERGY STAR fans match Commercial Electric BPT13-12EN closely?

Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
MaxLite EBF17-50-1-W 50 / 49.3 CFM 1.0 sones (Same) 3.7 CFM/W 3 in. diameter
Tech Drive FA-BF-01-L 50 / 45.1 CFM 1.0 sones (Same) 3.8 CFM/W 3 in. diameter
HomeWerks Worldwide 7140-50 50 / 43.4 CFM 1.0 sones (Same) 3.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7140-50-G3 50 / 36.1 CFM 1.0 sones (Same) 3.0 CFM/W 4 in. diameter
VOTATEC VO-FN4W18-AC-50 50 / 43.4 CFM 1.0 sones (Same) 3.0 CFM/W 4 in. diameter

Will Commercial Electric BPT13-12EN clear IRC M1505 in your bathroom?

Enter your room floor area and ceiling height below to verify whether Commercial Electric BPT13-12EN satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.

When does Commercial Electric BPT13-12EN fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Commercial Electric BPT13-12EN.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Recommended when: Bathroom floor <= 49 sq ft with 8-ft ceilings (43 sq ft at 9-ft height)
  • Target scenario: Exterior run uses smooth rigid metal matched to 3 in. diameter

What key rules and numbers govern Commercial Electric BPT13-12EN?

Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Commercial Electric BPT13-12EN.

Is Commercial Electric BPT13-12EN code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Commercial Electric BPT13-12EN clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Commercial Electric BPT13-12EN?

Do not force Commercial Electric BPT13-12EN into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Commercial Electric BPT13-12EN retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Commercial Electric BPT13-12EN produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 3 in. diameter metal duct transitions.

Will Commercial Electric BPT13-12EN disturb adjacent bedrooms during night use?

Acoustic measurement places Commercial Electric BPT13-12EN at 1.0 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Does running Commercial Electric BPT13-12EN continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Commercial Electric BPT13-12EN draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Commercial Electric BPT13-12EN pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BPT13-12EN's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Commercial Electric BPT13-12EN?

Commercial Electric BPT13-12EN features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Commercial Electric BPT13-12EN's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BPT13-12EN's safe coverage footprint from 50 sq ft to 44 sq ft.