Skip to main content
Grant Estimator

Commercial Electric BF1103 Exhaust Fan Specifications

ENERGY STAR PD #3531175 · Bathroom/Utility Room · Qualified 2024-05-24
Verified Specification Summary

Homeowners specifying Commercial Electric BF1103 gain 50 CFM at 0.1 in. w.g. (46.8 CFM at 0.25 in. w.g.) where it registers #265 of 607 in quietness (1.0 sones) and delivers 5.2 CFM/W efficacy, venting bathrooms up to 46 sq ft cleanly through 3 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Commercial Electric BF1103 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 46.8 CFM
Noise @ 0.1"
1.0 sones (#265/607)
Efficacy Rank
5.2 CFM/W (#499/1,145)
Static Retention
93.6% @ 0.25"
Motor Draw
9.6 W (3.5 kWh/yr)
Duct & Tier
3 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Commercial Electric BF1103 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 1.0 sones (#265 of 607 rated models, at the median tier among 607 rated models; quieter than 41.4% of rated models, equal to the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 46.8 CFM out of 50 CFM (93.6% retention, 5.9 pts higher retention than the 87.7% median). Keep 3 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Commercial Electric BF1103 (series: BF1103) under PD #3531175 (15 models registered, 2024-05-24). Lighting kit: Yes. At 5.2 CFM/W (#499 of 1,145, top 44.2% of 1,145 rated models, more efficient than 55.8% of rated models, 0.5 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 9.6 watts, about 3.5 kWh/yr (~$0.56/yr at $0.16/kWh) for 1 hr/day shower timers or 84.1 kWh/yr (~$13.46/yr) continuously. Closest competing matches include RAB CEP8S (50.0 CFM) and Tech Drive FA-BF-01-L (50.0 CFM).

What acoustic percentile does Commercial Electric BF1103 occupy among 1,145 bath blowers?

Inspect how Commercial Electric BF1103 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 1.0 sone: 1 sones (59th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 1.0 sone: 1 sones (P59)

Which exterior damper path suits Commercial Electric BF1103 best?

Exterior roof or wall damper termination paired with insulated 3 in. diameter metal pipe prevents condensation buildup around Commercial Electric BF1103 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Commercial Electric BF1103 acoustic and static metrics stand?

Compare Commercial Electric BF1103 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Commercial Electric (15 models) ENERGY STAR Certified Partner
Model Number & Series BF1103 / BF1103 PD ID 3531175 (Qualified 2024-05-24)
Duct Connection 3 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (46.8 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (1.0 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

Can Commercial Electric BF1103 handle taller ceilings or walk-in tub steam?

Evaluate how Commercial Electric BF1103 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Commercial Electric BF1103
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 46 sq ft1 CFM/sq ft @ 46.8 CFM
Tall Bath (9-ft Ceiling)Up to 41 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)3.5 kWh/yr (~$0.56/yr)9.6 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.284.1 kWh/yr (~$13.46/yr)9.6 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Commercial Electric BF1103?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
RAB CEP8S 50 / 48.8 CFM 1.0 sones (Same) 5.1 CFM/W 3 in. diameter
Tech Drive FA-BF-01-L 50 / 45.1 CFM 1.0 sones (Same) 3.8 CFM/W 3 in. diameter
MaxLite EBF17-50-1-W 50 / 49.3 CFM 1.0 sones (Same) 3.7 CFM/W 3 in. diameter
Air King BFQL50 50 / 39.3 CFM 0.8 sones (-0.20) 4.4 CFM/W 4 in. diameter
Air King WML50 50 / 39.3 CFM 0.8 sones (-0.20) 4.4 CFM/W 4 in. diameter

Is Commercial Electric BF1103 sized right for your shower or tub room?

Check whether Commercial Electric BF1103 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Commercial Electric BF1103?

Compare where Commercial Electric BF1103 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Supplementary continuous trickle ventilation
  • Suited to: Collar pairs with 3 in. diameter duct straight outdoors

Which code checks and cost facts matter for Commercial Electric BF1103?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Commercial Electric BF1103.

How does Commercial Electric BF1103 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Commercial Electric BF1103 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 3 in. diameter rigid metal ducting protects real exhaust.

Is Commercial Electric BF1103 quiet enough for a primary bedroom bathroom?

At 1.0 sones, Commercial Electric BF1103 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Commercial Electric BF1103 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Commercial Electric BF1103 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Commercial Electric BF1103's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Commercial Electric BF1103?

Commercial Electric BF1103 features a 3 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Commercial Electric BF1103's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Commercial Electric BF1103's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Commercial Electric BF1103 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Commercial Electric BF1103 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Commercial Electric BF1103 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Commercial Electric BF1103 lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories