Air King BFQL50 Exhaust Fan Specifications

ENERGY STAR PD #2301132 · Bathroom/Utility Room · Qualified 2017-07-28
Verified Specification Summary

Certified by EPA ENERGY STAR, Air King BFQL50 delivers 50 CFM free-air (39.3 CFM at 0.25 in. w.g.) and registers #194 of 607 in quietness (0.8 sones) and delivers 4.4 CFM/W efficacy, clearing residential IRC M1505 sizing up to 39 sq ft (8-ft height) or 34 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King BFQL50 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 39.3 CFM
Noise @ 0.1"
0.8 sones (#194/607)
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
78.6% @ 0.25"
Motor Draw
11.4 W (4.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Air King BFQL50 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 50 CFM open-air to 39.3 CFM at 0.25 in. w.g. (78.6% retention, 9.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Air King maintains 62 active ENERGY STAR blowers; BFQL50 (series: Air King) (PD #2301132) gained qualification on 2017-07-28. Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 11.4 watts, about 4.2 kWh/yr (~$0.67/yr at $0.16/kWh) for 1 hr/day shower timers or 99.9 kWh/yr (~$15.98/yr) continuously. Closest competing matches include Broan-Nutone BENL5 (50.0 CFM) and HomeWerks Worldwide 7141-50 (50.0 CFM).

How noisy is Air King BFQL50 compared with 1,145 certified bath fans?

Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Air King BFQL50 measures 0.8 sones across the 1,145-model registry.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.8 sone: 0.8 sones (39th percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.8 sone: 0.8 sones (P39)

Why does rigid 4 in. diameter ducting protect Air King BFQL50 airflow?

Connecting Air King BFQL50 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What laboratory specs verify Air King BFQL50 performance?

Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King BFQL50 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Air King (62 models) ENERGY STAR Certified Partner
Model Number & Series BFQL50 / Air King PD ID 2301132 (Qualified 2017-07-28)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (39.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.8 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What room sizes and annual power draw fit Air King BFQL50?

Calculated coverage metrics translate Air King BFQL50 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.

Bathroom sizing limits and annual kWh draw for Air King BFQL50
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 39 sq ft1 CFM/sq ft @ 39.3 CFM
Tall Bath (9-ft Ceiling)Up to 34 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)4.2 kWh/yr (~$0.67/yr)11.4 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.299.9 kWh/yr (~$15.98/yr)11.4 W x 8,760 hrs / 1,000

What alternative bath fans offer similar CFM to Air King BFQL50?

Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan-Nutone BENL5 50 / 49.5 CFM 0.7 sones (-0.10) 3.4 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-50 50 / 36.3 CFM 0.7 sones (-0.10) 3.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-50-G4 50 / 35.9 CFM 0.7 sones (-0.10) 2.9 CFM/W 4 in. diameter
Commercial Electric BF1101 50 / 45.9 CFM 1.0 sones (+0.20) 5.0 CFM/W 3 in. diameter
Tech Drive FA-BF-01-L 50 / 45.1 CFM 1.0 sones (+0.20) 3.8 CFM/W 3 in. diameter

Does Air King BFQL50 match your room square footage?

Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King BFQL50 percentage capacity without sending data.

When does Air King BFQL50 fail to fit a residential bathroom?

Confirm exhaust duct diameter, static supply pressure, and floor drain slope constraints carefully below prior to ordering Air King BFQL50.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Recommended when: Supplementary continuous trickle ventilation
  • Target scenario: Collar pairs with 4 in. diameter duct straight outdoors

Which homeowner questions come up most for Air King BFQL50?

Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King BFQL50.

Does running Air King BFQL50 continuously spike household electricity use?

Using ENERGY STAR airflow verification, 24/7 operation of Air King BFQL50 draws ~continuous ASHRAE duty annually versus ~low intermittent draw for 1-hour daily use, depending on local utility tariffs.

Can Air King BFQL50 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King BFQL50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Air King BFQL50?

Air King BFQL50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Air King BFQL50's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King BFQL50's safe coverage footprint from 50 sq ft to 44 sq ft.

Is Air King BFQL50 code-compliant for residential exhaust under IRC M1505?

Delivering 50 CFM net airflow (50 CFM free-air; unlisted 0.25 in. w.g. backpressure figures), Air King BFQL50 clears residential 50 CFM intermittent rules across baths up to 50 sq ft while meeting 20 CFM continuous ASHRAE 62.2 baselines.

Which bathroom layouts should pick a larger blower than Air King BFQL50?

Do not force Air King BFQL50 into spacious suites beyond 50 sq ft, tall 9-ft baths over 44 sq ft, steam enclosures needing +50 CFM above 20 sq ft, or multi-bend 3-in attic flex ducts.

How much airflow does Air King BFQL50 retain under real duct backpressure?

Under HVI 0.25 in. w.g. static pressure testing, Air King BFQL50 produces unlisted 0.25 in. w.g. backpressure figures versus 50 CFM at 0.1 in. w.g., favoring short straight 4 in. diameter metal duct transitions.

Will Air King BFQL50 disturb adjacent bedrooms during night use?

Acoustic measurement places Air King BFQL50 at 0.8 sones, meaning it operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan when paired with an insulated exterior damper.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)