Skip to main content
Grant Estimator

Broan-Nutone BENL5 Exhaust Fan Specifications

ENERGY STAR PD #3554015 · Bathroom/Utility Room · Qualified 2024-05-03
Verified Specification Summary

Tested under HVI protocols, the Broan-Nutone BENL5 exhaust unit achieves 50 CFM at 0.1 in. w.g. (49.5 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 3.4 CFM/W efficacy, covering standard baths up to 49 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan-Nutone BENL5 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
50 / 49.5 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
3.4 CFM/W (#1,060/1,145)
Static Retention
99.0% @ 0.25"
Motor Draw
14.7 W (5.4 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan-Nutone BENL5 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 49.5 CFM out of 50 CFM (99.0% retention, 11.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan-Nutone BENL5 (series: ROOMSIDE) under PD #3554015 (48 models registered, 2024-05-03). Lighting kit: Yes. At 3.4 CFM/W (#1,060 of 1,145, below median tier among 1,145 rated models; more efficient than 6.0% of rated models, 1.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 14.7 watts, about 5.4 kWh/yr (~$0.86/yr at $0.16/kWh) for 1 hr/day shower timers or 128.8 kWh/yr (~$20.61/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-50 (50.0 CFM) and HomeWerks Worldwide 7141-50-G4 (50.0 CFM).

Where do Broan-Nutone BENL5 sones rank across EPA ENERGY STAR fans?

Comparing Broan-Nutone BENL5 (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

What attic duct routing preserves Broan-Nutone BENL5 CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Broan-Nutone BENL5, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does Broan-Nutone BENL5 measure up on airflow and noise ratings?

Each row below breaks down Broan-Nutone BENL5 certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan-Nutone (48 models) ENERGY STAR Certified Partner
Model Number & Series BENL5 / ROOMSIDE PD ID 3554015 (Qualified 2024-05-03)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check CONTINUOUS ONLY (49.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect Broan-Nutone BENL5 CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for Broan-Nutone BENL5
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 49 sq ft1 CFM/sq ft @ 49.5 CFM
Tall Bath (9-ft Ceiling)Up to 44 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.4 kWh/yr (~$0.86/yr)14.7 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2128.8 kWh/yr (~$20.61/yr)14.7 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against Broan-Nutone BENL5?

Compare Broan-Nutone BENL5 side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
HomeWerks Worldwide 7141-50 50 / 36.3 CFM 0.7 sones (Same) 3.0 CFM/W 4 in. diameter
HomeWerks Worldwide 7141-50-G4 50 / 35.9 CFM 0.7 sones (Same) 2.9 CFM/W 4 in. diameter
Air King FR50 50 / 42 CFM 0.6 sones (-0.10) 3.5 CFM/W 4 in. diameter
Air King BFQ50 50 / 37.4 CFM 0.6 sones (-0.10) 2.9 CFM/W 4 in. diameter
Air King WM50 50 / 37.4 CFM 0.6 sones (-0.10) 2.9 CFM/W 4 in. diameter

Can you size Broan-Nutone BENL5 for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan-Nutone BENL5 verified capacity.

Who should not install Broan-Nutone BENL5 in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting Broan-Nutone BENL5 for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 49.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 0.7 sones up to 49 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to Broan-Nutone BENL5?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan-Nutone BENL5.

Why check Broan-Nutone BENL5 CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, Broan-Nutone BENL5 registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does Broan-Nutone BENL5 sound output compare to noisy contractor-grade fans?

Rated at 0.7 sones, Broan-Nutone BENL5 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define Broan-Nutone BENL5?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can Broan-Nutone BENL5 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan-Nutone BENL5's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan-Nutone BENL5?

Broan-Nutone BENL5 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan-Nutone BENL5's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan-Nutone BENL5's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan-Nutone BENL5 satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), Broan-Nutone BENL5 clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is Broan-Nutone BENL5 undersized or poorly matched for a bath renovation?

Skip Broan-Nutone BENL5 if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories