Certified by EPA ENERGY STAR, Air King BFQ50 delivers 50 CFM free-air (37.4 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 2.9 CFM/W efficacy, clearing residential IRC M1505 sizing up to 37 sq ft (8-ft height) or 33 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Air King BFQ50 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 50 / 37.4 CFM
- Noise @ 0.1"
- 0.6 sones (#107/607)
- Efficacy Rank
- 2.9 CFM/W (#1,132/1,145)
- Static Retention
- 74.8% @ 0.25"
- Motor Draw
- 17.2 W (6.3 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Air King BFQ50 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 50 CFM open-air to 37.4 CFM at 0.25 in. w.g. (74.8% retention, 12.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Air King maintains 62 active ENERGY STAR blowers; BFQ50 (series: N/A) (PD #2251571) gained qualification on 2015-10-01. Lighting kit: No. At 2.9 CFM/W (#1,132 of 1,145, tied with 13 other rated models at 2.9 CFM/W, 1.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.2 watts, about 6.3 kWh/yr (~$1.01/yr at $0.16/kWh) for 1 hr/day shower timers or 150.7 kWh/yr (~$24.11/yr) continuously. Closest competing matches include HomeWerks Worldwide 7141-50-G4 (50.0 CFM) and HomeWerks Worldwide 7141-50 (50.0 CFM).
How noisy is Air King BFQ50 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Air King BFQ50 measures 0.6 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Air King BFQ50 airflow?
Connecting Air King BFQ50 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Air King BFQ50 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Air King BFQ50 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Air King (62 models) | ENERGY STAR Certified Partner |
| Model Number & Series | BFQ50 / N/A | PD ID 2251571 (Qualified 2015-10-01) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | CONTINUOUS ONLY (37.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Air King BFQ50?
Calculated coverage metrics translate Air King BFQ50 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 37 sq ft | 1 CFM/sq ft @ 37.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 33 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.3 kWh/yr (~$1.01/yr) | 17.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 150.7 kWh/yr (~$24.11/yr) | 17.2 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Air King BFQ50?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| HomeWerks Worldwide 7141-50-G4 | 50 / 35.9 CFM | 0.7 sones (+0.10) | 2.9 CFM/W | 4 in. diameter |
| HomeWerks Worldwide 7141-50 | 50 / 36.3 CFM | 0.7 sones (+0.10) | 3.0 CFM/W | 4 in. diameter |
| Broan-Nutone BENL5 | 50 / 49.5 CFM | 0.7 sones (+0.10) | 3.4 CFM/W | 4 in. diameter |
| Broan AE50 | 50 / 51.9 CFM | 0.5 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Broan AE50=A000HF2WITHAE50F | 50 / 51.9 CFM | 0.5 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
Does Air King BFQ50 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Air King BFQ50 percentage capacity without sending data.
Does Air King BFQ50 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Air King BFQ50 for your remodel.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Strong scenario: Supplementary continuous trickle ventilation
- Best application: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Air King BFQ50?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Air King BFQ50.
How many kWh per year does Air King BFQ50 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Air King BFQ50 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Air King BFQ50 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Air King BFQ50's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Air King BFQ50?
Air King BFQ50 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Air King BFQ50's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Air King BFQ50's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Air King BFQ50 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Air King BFQ50 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Air King BFQ50 in a bathroom remodel?
Avoid specifying Air King BFQ50 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Air King BFQ50 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Air King BFQ50 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
What acoustic sone tier does Air King BFQ50 occupy in EPA filings?
With 0.6 sones at 0.1 in. w.g., Air King BFQ50 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)