Skip to main content
Grant Estimator

VENTECHLATION VF-BF-11L Exhaust Fan Specifications

ENERGY STAR PD #4697434 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

In EPA dataset 8dv7-nngq, VENTECHLATION VF-BF-11L tests at 80 CFM free discharge (71.2 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 71 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION VF-BF-11L Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 71.2 CFM
Noise @ 0.1"
0.6 sones (#107/607)
Efficacy Rank
4.5 CFM/W (#632/1,145)
Static Retention
89.0% @ 0.25"
Motor Draw
17.8 W (6.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does VENTECHLATION VF-BF-11L vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.2 CFM out of 80 CFM (89.0% retention, 1.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

VENTECHLATION maintains 12 active ENERGY STAR blowers; VF-BF-11L (series: VF) (PD #4697434) gained qualification on 2026-09-02. Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.8 watts, about 6.5 kWh/yr (~$1.04/yr at $0.16/kWh) for 1 hr/day shower timers or 155.9 kWh/yr (~$24.94/yr) continuously. Closest competing matches include Tech Drive TD-BF-04-plus (80.0 CFM) and AERO PURE ABF80L5OR (80.0 CFM).

Does VENTECHLATION VF-BF-11L fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with VENTECHLATION VF-BF-11L at 0.6 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.6 sone: 0.6 sones (22nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.6 sone: 0.6 sones (P22)

Why avoid unvented attic termination with VENTECHLATION VF-BF-11L?

Under ASHRAE 62.2 best practice, VENTECHLATION VF-BF-11L needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern VENTECHLATION VF-BF-11L?

Before cutting ceiling drywall or sizing attic transitions for VENTECHLATION VF-BF-11L, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share VENTECHLATION (12 models) ENERGY STAR Certified Partner
Model Number & Series VF-BF-11L / VF PD ID 4697434 (Qualified 2026-09-02)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (71.2 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.6 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit VENTECHLATION VF-BF-11L?

Bathroom ventilation sizing below maps VENTECHLATION VF-BF-11L motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for VENTECHLATION VF-BF-11L
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 71 sq ft1 CFM/sq ft @ 71.2 CFM
Tall Bath (9-ft Ceiling)Up to 63 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 21 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.5 kWh/yr (~$1.04/yr)17.8 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2155.9 kWh/yr (~$24.94/yr)17.8 W x 8,760 hrs / 1,000

What peer models sit nearest VENTECHLATION VF-BF-11L in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to VENTECHLATION VF-BF-11L.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Tech Drive TD-BF-04-plus 80 / 71.2 CFM 0.6 sones (Same) 4.5 CFM/W 4 in. diameter
AERO PURE ABF80L5OR 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SG 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SN 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5W 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter

What percentage of room demand does VENTECHLATION VF-BF-11L cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against VENTECHLATION VF-BF-11L tested delivery.

Who should not install VENTECHLATION VF-BF-11L in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting VENTECHLATION VF-BF-11L for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 71.2 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 0.6 sones up to 71 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for VENTECHLATION VF-BF-11L?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing VENTECHLATION VF-BF-11L.

Does VENTECHLATION VF-BF-11L satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION VF-BF-11L clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is VENTECHLATION VF-BF-11L undersized or poorly matched for a bath renovation?

Skip VENTECHLATION VF-BF-11L if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check VENTECHLATION VF-BF-11L CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, VENTECHLATION VF-BF-11L registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does VENTECHLATION VF-BF-11L sound output compare to noisy contractor-grade fans?

Rated at 0.6 sones, VENTECHLATION VF-BF-11L operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define VENTECHLATION VF-BF-11L?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can VENTECHLATION VF-BF-11L pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION VF-BF-11L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing VENTECHLATION VF-BF-11L?

VENTECHLATION VF-BF-11L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change VENTECHLATION VF-BF-11L's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION VF-BF-11L's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories