In EPA dataset 8dv7-nngq, VENTECHLATION VF-BF-11L tests at 80 CFM free discharge (71.2 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 4.5 CFM/W efficacy, meeting residential IRC M1505 sizing up to 71 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside VENTECHLATION VF-BF-11L Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 71.2 CFM
- Noise @ 0.1"
- 0.6 sones (#107/607)
- Efficacy Rank
- 4.5 CFM/W (#632/1,145)
- Static Retention
- 89.0% @ 0.25"
- Motor Draw
- 17.8 W (6.5 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does VENTECHLATION VF-BF-11L vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 71.2 CFM out of 80 CFM (89.0% retention, 1.3 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
VENTECHLATION maintains 12 active ENERGY STAR blowers; VF-BF-11L (series: VF) (PD #4697434) gained qualification on 2026-09-02. Lighting kit: Yes. At 4.5 CFM/W (#632 of 1,145, below median tier among 1,145 rated models; more efficient than 40.8% of rated models, 0.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 17.8 watts, about 6.5 kWh/yr (~$1.04/yr at $0.16/kWh) for 1 hr/day shower timers or 155.9 kWh/yr (~$24.94/yr) continuously. Closest competing matches include Tech Drive TD-BF-04-plus (80.0 CFM) and AERO PURE ABF80L5OR (80.0 CFM).
Does VENTECHLATION VF-BF-11L fall inside the quiet <=1.0 sone ENERGY STAR tier?
Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with VENTECHLATION VF-BF-11L at 0.6 sones.
Why avoid unvented attic termination with VENTECHLATION VF-BF-11L?
Under ASHRAE 62.2 best practice, VENTECHLATION VF-BF-11L needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.
What installation parameters govern VENTECHLATION VF-BF-11L?
Before cutting ceiling drywall or sizing attic transitions for VENTECHLATION VF-BF-11L, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | VENTECHLATION (12 models) | ENERGY STAR Certified Partner |
| Model Number & Series | VF-BF-11L / VF | PD ID 4697434 (Qualified 2026-09-02) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (71.2 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What daily runtime and room footprint suit VENTECHLATION VF-BF-11L?
Bathroom ventilation sizing below maps VENTECHLATION VF-BF-11L motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 71 sq ft | 1 CFM/sq ft @ 71.2 CFM |
| Tall Bath (9-ft Ceiling) | Up to 63 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 21 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.5 kWh/yr (~$1.04/yr) | 17.8 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 155.9 kWh/yr (~$24.94/yr) | 17.8 W x 8,760 hrs / 1,000 |
What peer models sit nearest VENTECHLATION VF-BF-11L in EPA test files?
Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to VENTECHLATION VF-BF-11L.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Tech Drive TD-BF-04-plus | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5OR | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5SG | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5SN | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5W | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
What percentage of room demand does VENTECHLATION VF-BF-11L cover?
Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against VENTECHLATION VF-BF-11L tested delivery.
Who should not install VENTECHLATION VF-BF-11L in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting VENTECHLATION VF-BF-11L for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 71.2 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 0.6 sones up to 71 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
Where do official rules set limits for VENTECHLATION VF-BF-11L?
Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing VENTECHLATION VF-BF-11L.
Does VENTECHLATION VF-BF-11L satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), VENTECHLATION VF-BF-11L clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is VENTECHLATION VF-BF-11L undersized or poorly matched for a bath renovation?
Skip VENTECHLATION VF-BF-11L if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check VENTECHLATION VF-BF-11L CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, VENTECHLATION VF-BF-11L registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does VENTECHLATION VF-BF-11L sound output compare to noisy contractor-grade fans?
Rated at 0.6 sones, VENTECHLATION VF-BF-11L operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define VENTECHLATION VF-BF-11L?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can VENTECHLATION VF-BF-11L pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from VENTECHLATION VF-BF-11L's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing VENTECHLATION VF-BF-11L?
VENTECHLATION VF-BF-11L features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change VENTECHLATION VF-BF-11L's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing VENTECHLATION VF-BF-11L's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)