Tested under HVI protocols, the AERO PURE ABF80L5SN exhaust unit achieves 80 CFM at 0.1 in. w.g. (61.4 CFM at 0.25 in. w.g.), registers #107 of 607 in quietness (0.6 sones) and delivers 4.4 CFM/W efficacy, covering standard baths up to 61 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF80L5SN Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 61.4 CFM
- Noise @ 0.1"
- 0.6 sones (#107/607)
- Efficacy Rank
- 4.4 CFM/W (#679/1,145)
- Static Retention
- 76.8% @ 0.25"
- Motor Draw
- 18.2 W (6.6 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does AERO PURE ABF80L5SN vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.4 CFM at 0.25 in. w.g. (76.8% retention, 10.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #4498424 verifies ABF80L5SN (series: ABF80L5SN) under AERO PURE (14 listed models, qualified 2025-06-06). Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Dayton 1UBH7B (80.0 CFM) and Greenheck SP-B80 (80.0 CFM).
Where do AERO PURE ABF80L5SN sones rank across EPA ENERGY STAR fans?
Comparing AERO PURE ABF80L5SN (0.6 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves AERO PURE ABF80L5SN CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AERO PURE ABF80L5SN, preventing premature peeling paint and mold growth.
How does AERO PURE ABF80L5SN measure up on airflow and noise ratings?
Each row below breaks down AERO PURE ABF80L5SN certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | AERO PURE (14 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ABF80L5SN / ABF80L5SN | PD ID 4498424 (Qualified 2025-06-06) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (61.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How does ceiling height affect AERO PURE ABF80L5SN CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 61 sq ft | 1 CFM/sq ft @ 61.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 54 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.6 kWh/yr (~$1.06/yr) | 18.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 159.4 kWh/yr (~$25.50/yr) | 18.2 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against AERO PURE ABF80L5SN?
Compare AERO PURE ABF80L5SN side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Dayton 1UBH7B | 80 / N/A CFM | 0.6 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| Greenheck SP-B80 | 80 / 62 CFM | 0.6 sones (Same) | 4.4 CFM/W | 6 in. diameter |
| Tech Drive TD-BF-04-plus | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| VENTECHLATION VF-BF-03 | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| VENTECHLATION VF-BF-11L | 80 / 71.2 CFM | 0.6 sones (Same) | 4.5 CFM/W | 4 in. diameter |
Can you size AERO PURE ABF80L5SN for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AERO PURE ABF80L5SN verified capacity.
Who should not install AERO PURE ABF80L5SN in a bathroom remodel?
Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AERO PURE ABF80L5SN for residential use.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 61.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Ideal fit: Target comfort around 0.6 sones up to 61 sq ft
- Primary match: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to AERO PURE ABF80L5SN?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AERO PURE ABF80L5SN.
Does AERO PURE ABF80L5SN satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?
With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AERO PURE ABF80L5SN clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.
When is AERO PURE ABF80L5SN undersized or poorly matched for a bath renovation?
Skip AERO PURE ABF80L5SN if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.
Why check AERO PURE ABF80L5SN CFM at 0.25 in. w.g. instead of open-air ratings?
Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AERO PURE ABF80L5SN registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.
How does AERO PURE ABF80L5SN sound output compare to noisy contractor-grade fans?
Rated at 0.6 sones, AERO PURE ABF80L5SN operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.
What electrical efficiency and runtime kWh define AERO PURE ABF80L5SN?
EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.
Can AERO PURE ABF80L5SN pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF80L5SN's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing AERO PURE ABF80L5SN?
AERO PURE ABF80L5SN features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change AERO PURE ABF80L5SN's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF80L5SN's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)