Skip to main content
Grant Estimator

AERO PURE ABF80L6W Exhaust Fan Specifications

ENERGY STAR PD #4498426 · Bathroom/Utility Room · Qualified 2025-06-06
Verified Specification Summary

Tested under HVI protocols, the AERO PURE ABF80L6W exhaust unit achieves 80 CFM at 0.1 in. w.g. (61.4 CFM at 0.25 in. w.g.), registers #107 of 607 in quietness (0.6 sones) and delivers 4.4 CFM/W efficacy, covering standard baths up to 61 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside AERO PURE ABF80L6W Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 61.4 CFM
Noise @ 0.1"
0.6 sones (#107/607)
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
76.8% @ 0.25"
Motor Draw
18.2 W (6.6 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does AERO PURE ABF80L6W vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 61.4 CFM at 0.25 in. w.g. (76.8% retention, 10.9 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms AERO PURE ABF80L6W (series: ABF80L6W) under PD #4498426 (14 models registered, 2025-06-06). Lighting kit: Yes. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include Dayton 1UBH7B (80.0 CFM) and Greenheck SP-B80 (80.0 CFM).

Where do AERO PURE ABF80L6W sones rank across EPA ENERGY STAR fans?

Comparing AERO PURE ABF80L6W (0.6 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.6 sone: 0.6 sones (22nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.6 sone: 0.6 sones (P22)

What attic duct routing preserves AERO PURE ABF80L6W CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on AERO PURE ABF80L6W, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does AERO PURE ABF80L6W measure up on airflow and noise ratings?

Each row below breaks down AERO PURE ABF80L6W certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share AERO PURE (14 models) ENERGY STAR Certified Partner
Model Number & Series ABF80L6W / ABF80L6W PD ID 4498426 (Qualified 2025-06-06)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (61.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.6 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

How does ceiling height affect AERO PURE ABF80L6W CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for AERO PURE ABF80L6W
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 61 sq ft1 CFM/sq ft @ 61.4 CFM
Tall Bath (9-ft Ceiling)Up to 54 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.6 kWh/yr (~$1.06/yr)18.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2159.4 kWh/yr (~$25.50/yr)18.2 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against AERO PURE ABF80L6W?

Compare AERO PURE ABF80L6W side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Dayton 1UBH7B 80 / N/A CFM 0.6 sones (Same) 4.4 CFM/W 6 in. diameter
Greenheck SP-B80 80 / 62 CFM 0.6 sones (Same) 4.4 CFM/W 6 in. diameter
Tech Drive TD-BF-04-plus 80 / 71.2 CFM 0.6 sones (Same) 4.5 CFM/W 4 in. diameter
VENTECHLATION VF-BF-03 80 / 71.2 CFM 0.6 sones (Same) 4.5 CFM/W 4 in. diameter
VENTECHLATION VF-BF-11L 80 / 71.2 CFM 0.6 sones (Same) 4.5 CFM/W 4 in. diameter

Can you size AERO PURE ABF80L6W for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against AERO PURE ABF80L6W verified capacity.

Who should not install AERO PURE ABF80L6W in a bathroom remodel?

Evaluate physical rough-in geometry, water supply capacity, and residential code clearance limits below before selecting AERO PURE ABF80L6W for residential use.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 61.4 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Ideal fit: Target comfort around 0.6 sones up to 61 sq ft
  • Primary match: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to AERO PURE ABF80L6W?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for AERO PURE ABF80L6W.

Does AERO PURE ABF80L6W satisfy IRC M1505 and ASHRAE 62.2 bathroom minimums?

With 50 CFM effective output (50 CFM at 0.1 in. w.g. and unlisted 0.25 in. w.g. backpressure figures), AERO PURE ABF80L6W clears the 50 CFM intermittent IRC M1505 standard for bathrooms up to 50 sq ft (8-ft ceilings) and exceeds the 20 CFM continuous floor.

When is AERO PURE ABF80L6W undersized or poorly matched for a bath renovation?

Skip AERO PURE ABF80L6W if your floor plan exceeds 50 sq ft (8-ft ceiling), climbs past 44 sq ft at 9-ft height, encloses a soaking tub over 20 sq ft, or vents through constricted 3-inch flex loops.

Why check AERO PURE ABF80L6W CFM at 0.25 in. w.g. instead of open-air ratings?

Real attic ducts with dampers create ~0.25 in. w.g. resistance. Whereas open-air flow is 50 CFM, AERO PURE ABF80L6W registers unlisted 0.25 in. w.g. backpressure figures, making rigid 4 in. diameter duct runs vital.

How does AERO PURE ABF80L6W sound output compare to noisy contractor-grade fans?

Rated at 0.6 sones, AERO PURE ABF80L6W operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; checking damper rattle and rigid duct vibration helps keep installed noise near lab ratings.

What electrical efficiency and runtime kWh define AERO PURE ABF80L6W?

EPA efficacy data (ENERGY STAR airflow verification) yields low intermittent draw across 365 intermittent hours or continuous ASHRAE duty for uninterrupted 8,760-hour ASHRAE 62.2 operation.

Can AERO PURE ABF80L6W pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from AERO PURE ABF80L6W's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing AERO PURE ABF80L6W?

AERO PURE ABF80L6W features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change AERO PURE ABF80L6W's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing AERO PURE ABF80L6W's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories