Skip to main content
Grant Estimator

Greenheck SP-B80 Exhaust Fan Specifications

ENERGY STAR PD #2335041 · Bathroom/Utility Room · Qualified 2015-10-15
Verified Specification Summary

Homeowners specifying Greenheck SP-B80 gain 80 CFM at 0.1 in. w.g. (62 CFM at 0.25 in. w.g.) where it registers #107 of 607 in quietness (0.6 sones) and delivers 4.4 CFM/W efficacy, venting bathrooms up to 62 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Greenheck SP-B80 Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 62 CFM
Noise @ 0.1"
0.6 sones (#107/607)
Efficacy Rank
4.4 CFM/W (#679/1,145)
Static Retention
77.5% @ 0.25"
Motor Draw
18.2 W (6.6 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Greenheck SP-B80 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 62 CFM at 0.25 in. w.g. (77.5% retention, 10.2 pts lower retention than the 87.7% median), making smooth 6 in. diameter rigid metal runs critical. The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Certification audit confirms Greenheck SP-B80 (series: SP) under PD #2335041 (31 models registered, 2015-10-15). Lighting kit: No. At 4.4 CFM/W (#679 of 1,145, below median tier among 1,145 rated models; more efficient than 37.4% of rated models, 0.3 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.2 watts, about 6.6 kWh/yr (~$1.06/yr at $0.16/kWh) for 1 hr/day shower timers or 159.4 kWh/yr (~$25.50/yr) continuously. Closest competing matches include AERO PURE ABF80L5OR (80.0 CFM) and AERO PURE ABF80L5SG (80.0 CFM).

What acoustic percentile does Greenheck SP-B80 occupy among 1,145 bath blowers?

Inspect how Greenheck SP-B80 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.6 sone: 0.6 sones (22nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.6 sone: 0.6 sones (P22)

Which exterior damper path suits Greenheck SP-B80 best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Greenheck SP-B80 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Greenheck SP-B80 acoustic and static metrics stand?

Compare Greenheck SP-B80 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Greenheck (31 models) ENERGY STAR Certified Partner
Model Number & Series SP-B80 / SP PD ID 2335041 (Qualified 2015-10-15)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (62 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.6 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Greenheck SP-B80 handle taller ceilings or walk-in tub steam?

Evaluate how Greenheck SP-B80 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Greenheck SP-B80
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 62 sq ft1 CFM/sq ft @ 62 CFM
Tall Bath (9-ft Ceiling)Up to 55 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.6 kWh/yr (~$1.06/yr)18.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2159.4 kWh/yr (~$25.50/yr)18.2 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Greenheck SP-B80?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
AERO PURE ABF80L5OR 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SG 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SN 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5W 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L6W 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter

Is Greenheck SP-B80 sized right for your shower or tub room?

Check whether Greenheck SP-B80 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Greenheck SP-B80?

Compare where Greenheck SP-B80 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 62 CFM net static output
  • Suited to: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Greenheck SP-B80?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Greenheck SP-B80.

How does Greenheck SP-B80 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Greenheck SP-B80 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Greenheck SP-B80 quiet enough for a primary bedroom bathroom?

At 0.6 sones, Greenheck SP-B80 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Greenheck SP-B80 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Greenheck SP-B80 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Greenheck SP-B80's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Greenheck SP-B80?

Greenheck SP-B80 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Greenheck SP-B80's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Greenheck SP-B80's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Greenheck SP-B80 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Greenheck SP-B80 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Greenheck SP-B80 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Greenheck SP-B80 lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories