Certified by EPA ENERGY STAR, Hunter 90704 delivers 80 CFM free-air (70.5 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 3.5 CFM/W efficacy, clearing residential IRC M1505 sizing up to 70 sq ft (8-ft height) or 62 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Hunter 90704 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 70.5 CFM
- Noise @ 0.1"
- 0.6 sones (#107/607)
- Efficacy Rank
- 3.5 CFM/W (#1,038/1,145)
- Static Retention
- 88.1% @ 0.25"
- Motor Draw
- 22.9 W (8.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Hunter 90704 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 70.5 CFM out of 80 CFM (88.1% retention, 0.4 pts higher retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Inside Hunter's 4-unit lineup, 90704 (series: 90704) carries PD #4498419 dating to 2025-09-05. Lighting kit: Yes. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Broan AE80 (80.0 CFM) and Broan AE80K (80.0 CFM).
How noisy is Hunter 90704 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Hunter 90704 measures 0.6 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Hunter 90704 airflow?
Connecting Hunter 90704 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Hunter 90704 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Hunter 90704 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Hunter (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | 90704 / 90704 | PD ID 4498419 (Qualified 2025-09-05) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (70.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
What room sizes and annual power draw fit Hunter 90704?
Calculated coverage metrics translate Hunter 90704 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 70 sq ft | 1 CFM/sq ft @ 70.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 62 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 20 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Hunter 90704?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AE80 | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| Broan AE80K | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| Broan AE80K = A000HFKT with AE80KF | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| Broan AE80K = A000HFKTC WITH AE80KF | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
| Broan AE80K = A000HFNF with AE80KF | 80 / 74.5 CFM | 0.6 sones (Same) | 3.9 CFM/W | 6 in. diameter |
Does Hunter 90704 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Hunter 90704 percentage capacity without sending data.
What plumbing or duct constraints rule out Hunter 90704?
Compare where Hunter 90704 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Enclosed jetted tub exceeds 20 sq ft at 0.25" w.g.
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Homeowner profile: Moisture load fits 70.5 CFM net static output
- Suited to: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Hunter 90704?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Hunter 90704.
How does Hunter 90704 handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Hunter 90704 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Hunter 90704 quiet enough for a primary bedroom bathroom?
At 0.6 sones, Hunter 90704 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Hunter 90704 energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Hunter 90704 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Hunter 90704's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Hunter 90704?
Hunter 90704 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Hunter 90704's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Hunter 90704's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Hunter 90704 serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Hunter 90704 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Hunter 90704 for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Hunter 90704 lacks adequate reserve.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)