Broan AE80K = A000HFKTC WITH AE80KF Exhaust Fan Specifications

ENERGY STAR PD #3999568 · Bathroom/Utility Room · Qualified 2025-03-07
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan AE80K = A000HFKTC WITH AE80KF tests at 80 CFM free discharge (74.5 CFM at 0.25 in. w.g.) and registers #107 of 607 in quietness (0.6 sones) and delivers 3.9 CFM/W efficacy, meeting residential IRC M1505 sizing up to 74 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80K = A000HFKTC WITH AE80KF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 74.5 CFM
Noise @ 0.1"
0.6 sones (#107/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
93.1% @ 0.25"
Motor Draw
20.5 W (7.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE80K = A000HFKTC WITH AE80KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 74.5 CFM out of 80 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

EPA filing PD #3999568 verifies AE80K = A000HFKTC WITH AE80KF (series: FLEX SERIES) under Broan (207 listed models, qualified 2025-03-07). Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Hunter 90704 (80.0 CFM) and Hunter 90705 (80.0 CFM).

Does Broan AE80K = A000HFKTC WITH AE80KF fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan AE80K = A000HFKTC WITH AE80KF at 0.6 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.6 sone: 0.6 sones (22nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.6 sone: 0.6 sones (P22)

Why avoid unvented attic termination with Broan AE80K = A000HFKTC WITH AE80KF?

Under ASHRAE 62.2 best practice, Broan AE80K = A000HFKTC WITH AE80KF needs insulated 6 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan AE80K = A000HFKTC WITH AE80KF?

Before cutting ceiling drywall or sizing attic transitions for Broan AE80K = A000HFKTC WITH AE80KF, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE80K = A000HFKTC WITH AE80KF / FLEX SERIES PD ID 3999568 (Qualified 2025-03-07)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (74.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.6 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Broan AE80K = A000HFKTC WITH AE80KF?

Bathroom ventilation sizing below maps Broan AE80K = A000HFKTC WITH AE80KF motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan AE80K = A000HFKTC WITH AE80KF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 74 sq ft1 CFM/sq ft @ 74.5 CFM
Tall Bath (9-ft Ceiling)Up to 66 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 24 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2179.6 kWh/yr (~$28.74/yr)20.5 W x 8,760 hrs / 1,000

What peer models sit nearest Broan AE80K = A000HFKTC WITH AE80KF in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan AE80K = A000HFKTC WITH AE80KF.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hunter 90704 80 / 70.5 CFM 0.6 sones (Same) 3.5 CFM/W 4 in. diameter
Hunter 90705 80 / 70.5 CFM 0.6 sones (Same) 3.5 CFM/W 4 in. diameter
AERO PURE ABF80L5OR 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SG 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SN 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter

What percentage of room demand does Broan AE80K = A000HFKTC WITH AE80KF cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan AE80K = A000HFKTC WITH AE80KF tested delivery.

Where should contractors skip Broan AE80K = A000HFKTC WITH AE80KF on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE80K = A000HFKTC WITH AE80KF carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 74.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 0.6 sones up to 74 sq ft
  • Works well for: Paired with rigid galvanized 6 in. diameter transition

Where do official rules set limits for Broan AE80K = A000HFKTC WITH AE80KF?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan AE80K = A000HFKTC WITH AE80KF.

What duct and room conditions disqualify Broan AE80K = A000HFKTC WITH AE80KF?

Rule out Broan AE80K = A000HFKTC WITH AE80KF when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan AE80K = A000HFKTC WITH AE80KF capacity?

Because static drag at 0.25 in. w.g. lowers Broan AE80K = A000HFKTC WITH AE80KF from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan AE80K = A000HFKTC WITH AE80KF compared with a standard 3.0 sone builder fan?

Tested at 0.6 sones, Broan AE80K = A000HFKTC WITH AE80KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Broan AE80K = A000HFKTC WITH AE80KF consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan AE80K = A000HFKTC WITH AE80KF draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan AE80K = A000HFKTC WITH AE80KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80K = A000HFKTC WITH AE80KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE80K = A000HFKTC WITH AE80KF?

Broan AE80K = A000HFKTC WITH AE80KF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE80K = A000HFKTC WITH AE80KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80K = A000HFKTC WITH AE80KF's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan AE80K = A000HFKTC WITH AE80KF score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE80K = A000HFKTC WITH AE80KF delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)