Rated for 80 CFM open-air (74.5 CFM at 0.25 in. w.g.), Broan AE80K = A000HFKT with AE80KF registers #107 of 607 in quietness (0.6 sones) and delivers 3.9 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 74 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80K = A000HFKT with AE80KF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 74.5 CFM
- Noise @ 0.1"
- 0.6 sones (#107/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 93.1% @ 0.25"
- Motor Draw
- 20.5 W (7.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan AE80K = A000HFKT with AE80KF vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 74.5 CFM out of 80 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Broan's 207-unit lineup, AE80K = A000HFKT with AE80KF (series: INVENT) carries PD #4697774 dating to 2026-09-02. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Hunter 90704 (80.0 CFM) and Hunter 90705 (80.0 CFM).
How does Broan AE80K = A000HFKT with AE80KF acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan AE80K = A000HFKT with AE80KF (0.6 sones).
How do flex elbows choke Broan AE80K = A000HFKT with AE80KF at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 6 in. diameter metal pipe keeps Broan AE80K = A000HFKT with AE80KF moving full rated CFM.
Does Broan AE80K = A000HFKT with AE80KF meet residential exhaust fan code specs?
Inspect Broan AE80K = A000HFKT with AE80KF mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80K = A000HFKT with AE80KF / INVENT | PD ID 4697774 (Qualified 2026-09-02) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (74.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan AE80K = A000HFKT with AE80KF airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan AE80K = A000HFKT with AE80KF tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 74 sq ft | 1 CFM/sq ft @ 74.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 66 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 24 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |
Which competing models share Broan AE80K = A000HFKT with AE80KF airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hunter 90704 | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Hunter 90705 | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5OR | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5SG | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5SN | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
How much airflow margin does Broan AE80K = A000HFKT with AE80KF give your bath?
Run a quick local room-volume check for Broan AE80K = A000HFKT with AE80KF by entering square footage and ceiling height to spot under-vented steam risks early.
What plumbing or duct constraints rule out Broan AE80K = A000HFKT with AE80KF?
Compare where Broan AE80K = A000HFKT with AE80KF excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- Steam or walk-in tub room > 24 sq ft requiring +50 CFM boost
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Homeowner profile: Bathroom floor <= 74 sq ft with 8-ft ceilings (66 sq ft at 9-ft height)
- Suited to: Exterior run uses smooth rigid metal matched to 6 in. diameter
What should homeowners verify first about Broan AE80K = A000HFKT with AE80KF?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan AE80K = A000HFKT with AE80KF.
Why might a contractor swap Broan AE80K = A000HFKT with AE80KF for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE80K = A000HFKT with AE80KF lacks adequate reserve.
How does Broan AE80K = A000HFKT with AE80KF handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE80K = A000HFKT with AE80KF yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.
Is Broan AE80K = A000HFKT with AE80KF quiet enough for a primary bedroom bathroom?
At 0.6 sones, Broan AE80K = A000HFKT with AE80KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Is Broan AE80K = A000HFKT with AE80KF energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Broan AE80K = A000HFKT with AE80KF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80K = A000HFKT with AE80KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80K = A000HFKT with AE80KF?
Broan AE80K = A000HFKT with AE80KF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80K = A000HFKT with AE80KF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80K = A000HFKT with AE80KF's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Broan AE80K = A000HFKT with AE80KF serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Broan AE80K = A000HFKT with AE80KF supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)