Skip to main content
Grant Estimator

Broan AE80K = A000HFNF with AE80KF Exhaust Fan Specifications

ENERGY STAR PD #4697734 · Bathroom/Utility Room · Qualified 2026-09-02
Verified Specification Summary

Homeowners specifying Broan AE80K = A000HFNF with AE80KF gain 80 CFM at 0.1 in. w.g. (74.5 CFM at 0.25 in. w.g.) where it registers #107 of 607 in quietness (0.6 sones) and delivers 3.9 CFM/W efficacy, venting bathrooms up to 74 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80K = A000HFNF with AE80KF Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 74.5 CFM
Noise @ 0.1"
0.6 sones (#107/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
93.1% @ 0.25"
Motor Draw
20.5 W (7.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE80K = A000HFNF with AE80KF vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 74.5 CFM out of 80 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Inside Broan's 207-unit lineup, AE80K = A000HFNF with AE80KF (series: INVENT) carries PD #4697734 dating to 2026-09-02. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Hunter 90704 (80.0 CFM) and Hunter 90705 (80.0 CFM).

What acoustic percentile does Broan AE80K = A000HFNF with AE80KF occupy among 1,145 bath blowers?

Inspect how Broan AE80K = A000HFNF with AE80KF positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.6 sone: 0.6 sones (22nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.6 sone: 0.6 sones (P22)

Which exterior damper path suits Broan AE80K = A000HFNF with AE80KF best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Broan AE80K = A000HFNF with AE80KF housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan AE80K = A000HFNF with AE80KF acoustic and static metrics stand?

Compare Broan AE80K = A000HFNF with AE80KF published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE80K = A000HFNF with AE80KF / INVENT PD ID 4697734 (Qualified 2026-09-02)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (74.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.6 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Broan AE80K = A000HFNF with AE80KF handle taller ceilings or walk-in tub steam?

Evaluate how Broan AE80K = A000HFNF with AE80KF scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan AE80K = A000HFNF with AE80KF
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 74 sq ft1 CFM/sq ft @ 74.5 CFM
Tall Bath (9-ft Ceiling)Up to 66 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 24 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2179.6 kWh/yr (~$28.74/yr)20.5 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan AE80K = A000HFNF with AE80KF?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hunter 90704 80 / 70.5 CFM 0.6 sones (Same) 3.5 CFM/W 4 in. diameter
Hunter 90705 80 / 70.5 CFM 0.6 sones (Same) 3.5 CFM/W 4 in. diameter
AERO PURE ABF80L5OR 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SG 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SN 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter

Is Broan AE80K = A000HFNF with AE80KF sized right for your shower or tub room?

Check whether Broan AE80K = A000HFNF with AE80KF clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

Where should contractors skip Broan AE80K = A000HFNF with AE80KF on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Broan AE80K = A000HFNF with AE80KF carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 24 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Choose this if: Moisture load fits 74.5 CFM net static output
  • Works well for: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan AE80K = A000HFNF with AE80KF?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AE80K = A000HFNF with AE80KF.

How much power does Broan AE80K = A000HFNF with AE80KF consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Broan AE80K = A000HFNF with AE80KF draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Broan AE80K = A000HFNF with AE80KF pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80K = A000HFNF with AE80KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE80K = A000HFNF with AE80KF?

Broan AE80K = A000HFNF with AE80KF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE80K = A000HFNF with AE80KF's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80K = A000HFNF with AE80KF's safe coverage footprint from 50 sq ft to 44 sq ft.

How does Broan AE80K = A000HFNF with AE80KF score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Broan AE80K = A000HFNF with AE80KF delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Broan AE80K = A000HFNF with AE80KF?

Rule out Broan AE80K = A000HFNF with AE80KF when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Broan AE80K = A000HFNF with AE80KF capacity?

Because static drag at 0.25 in. w.g. lowers Broan AE80K = A000HFNF with AE80KF from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 6 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Broan AE80K = A000HFNF with AE80KF compared with a standard 3.0 sone builder fan?

Tested at 0.6 sones, Broan AE80K = A000HFNF with AE80KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories