Skip to main content
Grant Estimator

Broan AE80S = A000HFS with AE80F1 Exhaust Fan Specifications

ENERGY STAR PD #2369234 · Bathroom/Utility Room · Qualified 2020-11-06
Verified Specification Summary

Homeowners specifying Broan AE80S = A000HFS with AE80F1 gain 80 CFM at 0.1 in. w.g. (74.5 CFM at 0.25 in. w.g.) where it registers #107 of 607 in quietness (0.6 sones) and delivers 3.9 CFM/W efficacy, venting bathrooms up to 74 sq ft cleanly through 6 in. diameter rigid metal ducting. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80S = A000HFS with AE80F1 Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 74.5 CFM
Noise @ 0.1"
0.6 sones (#107/607)
Efficacy Rank
3.9 CFM/W (#876/1,145)
Static Retention
93.1% @ 0.25"
Motor Draw
20.5 W (7.5 kWh/yr)
Duct & Tier
6 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE80S = A000HFS with AE80F1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 74.5 CFM out of 80 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.

Broan maintains 207 active ENERGY STAR blowers; AE80S = A000HFS with AE80F1 (series: INVENT) (PD #2369234) gained qualification on 2020-11-06. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Hunter 90704 (80.0 CFM) and Hunter 90705 (80.0 CFM).

What acoustic percentile does Broan AE80S = A000HFS with AE80F1 occupy among 1,145 bath blowers?

Inspect how Broan AE80S = A000HFS with AE80F1 positions acoustically inside EPA's 1,145-model ventilating catalog, where 356 units hit quiet 1.0 sone thresholds.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.6 sone: 0.6 sones (22nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.6 sone: 0.6 sones (P22)

Which exterior damper path suits Broan AE80S = A000HFS with AE80F1 best?

Exterior roof or wall damper termination paired with insulated 6 in. diameter metal pipe prevents condensation buildup around Broan AE80S = A000HFS with AE80F1 housings.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Where do Broan AE80S = A000HFS with AE80F1 acoustic and static metrics stand?

Compare Broan AE80S = A000HFS with AE80F1 published sound levels, motor efficacy ratios, and qualification dates directly against national ENERGY STAR bath fan thresholds summarized below.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE80S = A000HFS with AE80F1 / INVENT PD ID 2369234 (Qualified 2020-11-06)
Duct Connection 6 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (74.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.6 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Can Broan AE80S = A000HFS with AE80F1 handle taller ceilings or walk-in tub steam?

Evaluate how Broan AE80S = A000HFS with AE80F1 scales from standard 8-foot bath enclosures to 9-foot ceilings or +50 CFM soaking-tub reserves alongside expected yearly kWh draw.

Bathroom sizing limits and annual kWh draw for Broan AE80S = A000HFS with AE80F1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 74 sq ft1 CFM/sq ft @ 74.5 CFM
Tall Bath (9-ft Ceiling)Up to 66 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Up to 24 sq ftSubtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)7.5 kWh/yr (~$1.20/yr)20.5 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2179.6 kWh/yr (~$28.74/yr)20.5 W x 8,760 hrs / 1,000

Are quieter or higher-efficacy peers available near Broan AE80S = A000HFS with AE80F1?

Review five closely matched certified bath fans below showing exact acoustic sone differences, dual static CFM figures, and duct collar sizes.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Hunter 90704 80 / 70.5 CFM 0.6 sones (Same) 3.5 CFM/W 4 in. diameter
Hunter 90705 80 / 70.5 CFM 0.6 sones (Same) 3.5 CFM/W 4 in. diameter
AERO PURE ABF80L5OR 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SG 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter
AERO PURE ABF80L5SN 80 / 61.4 CFM 0.6 sones (Same) 4.4 CFM/W 4 in. diameter

Is Broan AE80S = A000HFS with AE80F1 sized right for your shower or tub room?

Check whether Broan AE80S = A000HFS with AE80F1 clears residential 50 CFM minimums for your room dimensions and ceiling height using our local browser calculator.

What plumbing or duct constraints rule out Broan AE80S = A000HFS with AE80F1?

Compare where Broan AE80S = A000HFS with AE80F1 excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • Enclosed jetted tub exceeds 24 sq ft at 0.25" w.g.
  • Attic termination without exterior roof or wall backdraft damper

Best-Fit Homeowner Profiles

  • Homeowner profile: Moisture load fits 74.5 CFM net static output
  • Suited to: Collar pairs with 6 in. diameter duct straight outdoors

Which code checks and cost facts matter for Broan AE80S = A000HFS with AE80F1?

Inspect plain-English explanations below covering regulatory caps, safety precautions, rough-in clearances, and budget checks tied directly to Broan AE80S = A000HFS with AE80F1.

How does Broan AE80S = A000HFS with AE80F1 handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE80S = A000HFS with AE80F1 yields unlisted 0.25 in. w.g. backpressure figures, so smooth 6 in. diameter rigid metal ducting protects real exhaust.

Is Broan AE80S = A000HFS with AE80F1 quiet enough for a primary bedroom bathroom?

At 0.6 sones, Broan AE80S = A000HFS with AE80F1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan AE80S = A000HFS with AE80F1 energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan AE80S = A000HFS with AE80F1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80S = A000HFS with AE80F1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE80S = A000HFS with AE80F1?

Broan AE80S = A000HFS with AE80F1 features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE80S = A000HFS with AE80F1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80S = A000HFS with AE80F1's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Broan AE80S = A000HFS with AE80F1 serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan AE80S = A000HFS with AE80F1 supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Broan AE80S = A000HFS with AE80F1 for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE80S = A000HFS with AE80F1 lacks adequate reserve.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories