Tested under HVI protocols, the Broan AE80SK = A000HSKT with AE80KF exhaust unit achieves 80 CFM at 0.1 in. w.g. (74.5 CFM at 0.25 in. w.g.), registers #107 of 607 in quietness (0.6 sones) and delivers 3.9 CFM/W efficacy, covering standard baths up to 74 sq ft on a 6 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80SK = A000HSKT with AE80KF Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 74.5 CFM
- Noise @ 0.1"
- 0.6 sones (#107/607)
- Efficacy Rank
- 3.9 CFM/W (#876/1,145)
- Static Retention
- 93.1% @ 0.25"
- Motor Draw
- 20.5 W (7.5 kWh/yr)
- Duct & Tier
- 6 in. diameter · Standard

What does Broan AE80SK = A000HSKT with AE80KF vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.6 sones (#107 of 607 rated models, quietest 22.1% of 607 rated models, quieter than 77.9% of rated models, 0.40 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 74.5 CFM out of 80 CFM (93.1% retention, 5.4 pts higher retention than the 87.7% median). The 6-inch collar lowers air friction across longer attic runs—do not neck down to 3-inch flex.
Inside Broan's 207-unit lineup, AE80SK = A000HSKT with AE80KF (series: INVENT) carries PD #4697754 dating to 2026-09-02. Lighting kit: No. At 3.9 CFM/W (#876 of 1,145, below median tier among 1,145 rated models; more efficient than 17.0% of rated models, 0.8 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 20.5 watts, about 7.5 kWh/yr (~$1.20/yr at $0.16/kWh) for 1 hr/day shower timers or 179.6 kWh/yr (~$28.74/yr) continuously. Closest competing matches include Hunter 90704 (80.0 CFM) and Hunter 90705 (80.0 CFM).
Where do Broan AE80SK = A000HSKT with AE80KF sones rank across EPA ENERGY STAR fans?
Comparing Broan AE80SK = A000HSKT with AE80KF (0.6 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Broan AE80SK = A000HSKT with AE80KF CFM output?
Short straight 6 in. diameter duct paths retain up to ~82% of open-air capacity on Broan AE80SK = A000HSKT with AE80KF, preventing premature peeling paint and mold growth.
How does Broan AE80SK = A000HSKT with AE80KF measure up on airflow and noise ratings?
Each row below breaks down Broan AE80SK = A000HSKT with AE80KF certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80SK = A000HSKT with AE80KF / INVENT | PD ID 4697754 (Qualified 2026-09-02) |
| Duct Connection | 6 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (74.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.6 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Broan AE80SK = A000HSKT with AE80KF CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 74 sq ft | 1 CFM/sq ft @ 74.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 66 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Up to 24 sq ft | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 7.5 kWh/yr (~$1.20/yr) | 20.5 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 179.6 kWh/yr (~$28.74/yr) | 20.5 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Broan AE80SK = A000HSKT with AE80KF?
Compare Broan AE80SK = A000HSKT with AE80KF side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Hunter 90704 | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| Hunter 90705 | 80 / 70.5 CFM | 0.6 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5OR | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5SG | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
| AERO PURE ABF80L5SN | 80 / 61.4 CFM | 0.6 sones (Same) | 4.4 CFM/W | 4 in. diameter |
Can you size Broan AE80SK = A000HSKT with AE80KF for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Broan AE80SK = A000HSKT with AE80KF verified capacity.
Which bath layouts should avoid specifying Broan AE80SK = A000HSKT with AE80KF?
Match Broan AE80SK = A000HSKT with AE80KF directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 74.5 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.6 sones up to 74 sq ft
- Optimal use: Paired with rigid galvanized 6 in. diameter transition
How do federal and code standards apply to Broan AE80SK = A000HSKT with AE80KF?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Broan AE80SK = A000HSKT with AE80KF.
Where does Broan AE80SK = A000HSKT with AE80KF run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Broan AE80SK = A000HSKT with AE80KF.
What happens to Broan AE80SK = A000HSKT with AE80KF CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Broan AE80SK = A000HSKT with AE80KF moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 6 in. diameter collar.
Where does Broan AE80SK = A000HSKT with AE80KF sit on acoustic comfort for senior homeowners?
Measuring 0.6 sones, Broan AE80SK = A000HSKT with AE80KF operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Broan AE80SK = A000HSKT with AE80KF cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Broan AE80SK = A000HSKT with AE80KF 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Broan AE80SK = A000HSKT with AE80KF pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80SK = A000HSKT with AE80KF's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80SK = A000HSKT with AE80KF?
Broan AE80SK = A000HSKT with AE80KF features a 6 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80SK = A000HSKT with AE80KF's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80SK = A000HSKT with AE80KF's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Broan AE80SK = A000HSKT with AE80KF ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Broan AE80SK = A000HSKT with AE80KF covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)