Tested under HVI protocols, the S&P PCLP80XP exhaust unit achieves 80 CFM at 0.1 in. w.g. (68.3 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 4.7 CFM/W efficacy, covering standard baths up to 68 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP80XP Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 68.3 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 85.4% @ 0.25"
- Motor Draw
- 17.0 W (6.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does S&P PCLP80XP vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.3 CFM out of 80 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
EPA filing PD #2382121 verifies PCLP80XP (series: PCLP) under S&P (29 listed models, qualified 2021-06-25). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include ACIQ AES80 (80.0 CFM) and CFM TF80N (80.0 CFM).
Where do S&P PCLP80XP sones rank across EPA ENERGY STAR fans?
Comparing S&P PCLP80XP (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves S&P PCLP80XP CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on S&P PCLP80XP, preventing premature peeling paint and mold growth.
How does S&P PCLP80XP measure up on airflow and noise ratings?
Each row below breaks down S&P PCLP80XP certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | S&P (29 models) | ENERGY STAR Certified Partner |
| Model Number & Series | PCLP80XP / PCLP | PD ID 2382121 (Qualified 2021-06-25) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (68.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect S&P PCLP80XP CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 60 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 148.9 kWh/yr (~$23.82/yr) | 17.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against S&P PCLP80XP?
Compare S&P PCLP80XP side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AES80 | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| CFM TF80N | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Air King AK80LS | 80 / 61.5 CFM | 0.7 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Canarm CNP80 | 80 / 62.6 CFM | 0.7 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| Ortech ODE-8007 | 80 / 69.8 CFM | 0.7 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Can you size S&P PCLP80XP for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P PCLP80XP verified capacity.
Which bath layouts should avoid specifying S&P PCLP80XP?
Match S&P PCLP80XP directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 68.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Best for: Target comfort around 0.7 sones up to 68 sq ft
- Optimal use: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to S&P PCLP80XP?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P PCLP80XP.
What bathroom square footage can S&P PCLP80XP ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), S&P PCLP80XP covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does S&P PCLP80XP run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with S&P PCLP80XP.
What happens to S&P PCLP80XP CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, S&P PCLP80XP moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Where does S&P PCLP80XP sit on acoustic comfort for senior homeowners?
Measuring 0.7 sones, S&P PCLP80XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does S&P PCLP80XP cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running S&P PCLP80XP 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can S&P PCLP80XP pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP80XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing S&P PCLP80XP?
S&P PCLP80XP features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change S&P PCLP80XP's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP80XP's safe coverage footprint from 50 sq ft to 44 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)