S&P PCLP80XP Exhaust Fan Specifications

ENERGY STAR PD #2382121 · Bathroom/Utility Room · Qualified 2021-06-25
Verified Specification Summary

Tested under HVI protocols, the S&P PCLP80XP exhaust unit achieves 80 CFM at 0.1 in. w.g. (68.3 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 4.7 CFM/W efficacy, covering standard baths up to 68 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside S&P PCLP80XP Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 68.3 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
4.7 CFM/W (#545/1,145)
Static Retention
85.4% @ 0.25"
Motor Draw
17.0 W (6.2 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does S&P PCLP80XP vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.3 CFM out of 80 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

EPA filing PD #2382121 verifies PCLP80XP (series: PCLP) under S&P (29 listed models, qualified 2021-06-25). Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include ACIQ AES80 (80.0 CFM) and CFM TF80N (80.0 CFM).

Where do S&P PCLP80XP sones rank across EPA ENERGY STAR fans?

Comparing S&P PCLP80XP (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

What attic duct routing preserves S&P PCLP80XP CFM output?

Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on S&P PCLP80XP, preventing premature peeling paint and mold growth.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

How does S&P PCLP80XP measure up on airflow and noise ratings?

Each row below breaks down S&P PCLP80XP certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share S&P (29 models) ENERGY STAR Certified Partner
Model Number & Series PCLP80XP / PCLP PD ID 2382121 (Qualified 2021-06-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (68.3 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

How does ceiling height affect S&P PCLP80XP CFM capacity?

Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.

Bathroom sizing limits and annual kWh draw for S&P PCLP80XP
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 68 sq ft1 CFM/sq ft @ 68.3 CFM
Tall Bath (9-ft Ceiling)Up to 60 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)6.2 kWh/yr (~$0.99/yr)17.0 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2148.9 kWh/yr (~$23.82/yr)17.0 W x 8,760 hrs / 1,000

How do nearby ENERGY STAR blowers compare against S&P PCLP80XP?

Compare S&P PCLP80XP side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
ACIQ AES80 80 / 68.3 CFM 0.7 sones (Same) 4.7 CFM/W 4 in. diameter
CFM TF80N 80 / 68.3 CFM 0.7 sones (Same) 4.7 CFM/W 4 in. diameter
Air King AK80LS 80 / 61.5 CFM 0.7 sones (Same) 4.5 CFM/W 4 in. diameter
Canarm CNP80 80 / 62.6 CFM 0.7 sones (Same) 4.9 CFM/W 4 in. diameter
Ortech ODE-8007 80 / 69.8 CFM 0.7 sones (Same) 4.3 CFM/W 4 in. diameter

Can you size S&P PCLP80XP for a 9-ft or tall bath ceiling?

Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against S&P PCLP80XP verified capacity.

Which bath layouts should avoid specifying S&P PCLP80XP?

Match S&P PCLP80XP directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 68.3 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Best for: Target comfort around 0.7 sones up to 68 sq ft
  • Optimal use: Paired with rigid galvanized 4 in. diameter transition

How do federal and code standards apply to S&P PCLP80XP?

Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for S&P PCLP80XP.

What bathroom square footage can S&P PCLP80XP ventilate under ASHRAE 62.2?

Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), S&P PCLP80XP covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.

Where does S&P PCLP80XP run out of capacity in residential remodeling?

Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with S&P PCLP80XP.

What happens to S&P PCLP80XP CFM when vented through elbows and roof caps?

Against realistic 0.25 in. w.g. system resistance, S&P PCLP80XP moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.

Where does S&P PCLP80XP sit on acoustic comfort for senior homeowners?

Measuring 0.7 sones, S&P PCLP80XP operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.

What does S&P PCLP80XP cost in annual electricity for intermittent vs continuous duty?

Operating at ENERGY STAR airflow verification, running S&P PCLP80XP 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.

Can S&P PCLP80XP pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from S&P PCLP80XP's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing S&P PCLP80XP?

S&P PCLP80XP features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change S&P PCLP80XP's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing S&P PCLP80XP's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories