Certified by EPA ENERGY STAR, Ortech ODE-8007 delivers 80 CFM free-air (69.8 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 4.3 CFM/W efficacy, clearing residential IRC M1505 sizing up to 69 sq ft (8-ft height) or 62 sq ft at 9-ft ceilings. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Ortech ODE-8007 Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 69.8 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 4.3 CFM/W (#718/1,145)
- Static Retention
- 87.2% @ 0.25"
- Motor Draw
- 18.6 W (6.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Ortech ODE-8007 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 69.8 CFM out of 80 CFM (87.2% retention, 0.5 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Certification audit confirms Ortech ODE-8007 (series: ODE-8007) under PD #2731992 (27 models registered, 2023-10-13). Lighting kit: No. At 4.3 CFM/W (#718 of 1,145, below median tier among 1,145 rated models; more efficient than 32.5% of rated models, 0.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 18.6 watts, about 6.8 kWh/yr (~$1.09/yr at $0.16/kWh) for 1 hr/day shower timers or 162.9 kWh/yr (~$26.06/yr) continuously. Closest competing matches include ACIQ AEP80 (80.0 CFM) and Canarm CEP80 (80.0 CFM).
How noisy is Ortech ODE-8007 compared with 1,145 certified bath fans?
Human hearing scales linearly with sones: 356 ENERGY STAR fans reach <=1.0 sone, while Ortech ODE-8007 measures 0.7 sones across the 1,145-model registry.
Why does rigid 4 in. diameter ducting protect Ortech ODE-8007 airflow?
Connecting Ortech ODE-8007 through rigid 4 in. diameter steel pipe to an exterior damper cap minimizes backpressure loss and keeps ceiling moisture out of roof decking.
What laboratory specs verify Ortech ODE-8007 performance?
Tested under HVI 911 and ENERGY STAR protocols, the specification table for Ortech ODE-8007 lists static pressure CFM, acoustic output, wattage efficiency, and lighting setup.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Ortech (27 models) | ENERGY STAR Certified Partner |
| Model Number & Series | ODE-8007 / ODE-8007 | PD ID 2731992 (Qualified 2023-10-13) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (69.8 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
What room sizes and annual power draw fit Ortech ODE-8007?
Calculated coverage metrics translate Ortech ODE-8007 airflow against 1 CFM per sq ft room guidelines and continuous 24/7 ASHRAE 62.2 fan runtime budgets.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 69 sq ft | 1 CFM/sq ft @ 69.8 CFM |
| Tall Bath (9-ft Ceiling) | Up to 62 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.8 kWh/yr (~$1.09/yr) | 18.6 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 162.9 kWh/yr (~$26.06/yr) | 18.6 W x 8,760 hrs / 1,000 |
What alternative bath fans offer similar CFM to Ortech ODE-8007?
Five closest ENERGY STAR peers appear below, ranked by airflow proximity, sound rating differences, efficacy, and duct collar dimensions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Canarm CEP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Cyclone ESCBP80 | 80 / 70.9 CFM | 0.7 sones (Same) | 4.2 CFM/W | 6 in. diameter |
| Revent RVPR80 | 80 / 66.2 CFM | 0.7 sones (Same) | 4.2 CFM/W | 4 in. diameter |
| Air King AK80LS | 80 / 61.5 CFM | 0.7 sones (Same) | 4.5 CFM/W | 4 in. diameter |
Does Ortech ODE-8007 match your room square footage?
Test your exact bathroom length, width footprint, and ceiling height in browser JavaScript to check Ortech ODE-8007 percentage capacity without sending data.
Where should contractors skip Ortech ODE-8007 on bath bids?
Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Ortech ODE-8007 carefully below before approving contractor material schedules.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Attic termination without exterior roof or wall backdraft damper
Best-Fit Homeowner Profiles
- Choose this if: Moisture load fits 69.8 CFM net static output
- Works well for: Collar pairs with 4 in. diameter duct straight outdoors
Which homeowner questions come up most for Ortech ODE-8007?
Review direct source-backed homeowner answers below covering building code compliance, sizing limits, installation checks, and cost tradeoffs around Ortech ODE-8007.
Will long attic ducting choke Ortech ODE-8007 capacity?
Because static drag at 0.25 in. w.g. lowers Ortech ODE-8007 from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.
How loud is Ortech ODE-8007 compared with a standard 3.0 sone builder fan?
Tested at 0.7 sones, Ortech ODE-8007 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.
How much power does Ortech ODE-8007 consume per year at 1 hr/day vs 24/7?
Backed by ENERGY STAR airflow verification, Ortech ODE-8007 draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.
Can Ortech ODE-8007 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Ortech ODE-8007's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Ortech ODE-8007?
Ortech ODE-8007 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Ortech ODE-8007's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Ortech ODE-8007's safe coverage footprint from 50 sq ft to 44 sq ft.
How does Ortech ODE-8007 score against federal 50 CFM intermittent fan rules?
Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Ortech ODE-8007 delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.
What duct and room conditions disqualify Ortech ODE-8007?
Rule out Ortech ODE-8007 when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)