Tested under HVI protocols, the Milano TY-80-EH exhaust unit achieves 80 CFM at 0.1 in. w.g. (59.4 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 3.3 CFM/W efficacy, covering standard baths up to 59 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Milano TY-80-EH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 59.4 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 3.3 CFM/W (#1,077/1,145)
- Static Retention
- 74.2% @ 0.25"
- Motor Draw
- 24.2 W (8.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Milano TY-80-EH vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.4 CFM at 0.25 in. w.g. (74.2% retention, 13.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Milano maintains 6 active ENERGY STAR blowers; TY-80-EH (series: Humidity sensing) (PD #2340997) gained qualification on 2019-05-17. Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.2 watts, about 8.8 kWh/yr (~$1.41/yr at $0.16/kWh) for 1 hr/day shower timers or 212.0 kWh/yr (~$33.92/yr) continuously. Closest competing matches include Broan AE80B (80.0 CFM) and Broan AE80B = A000HFKT with AE80BF1 (80.0 CFM).
Where do Milano TY-80-EH sones rank across EPA ENERGY STAR fans?
Comparing Milano TY-80-EH (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves Milano TY-80-EH CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on Milano TY-80-EH, preventing premature peeling paint and mold growth.
How does Milano TY-80-EH measure up on airflow and noise ratings?
Each row below breaks down Milano TY-80-EH certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Milano (6 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TY-80-EH / Humidity sensing | PD ID 2340997 (Qualified 2019-05-17) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (59.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect Milano TY-80-EH CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 59 sq ft | 1 CFM/sq ft @ 59.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.8 kWh/yr (~$1.41/yr) | 24.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 212.0 kWh/yr (~$33.92/yr) | 24.2 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against Milano TY-80-EH?
Compare Milano TY-80-EH side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AE80B | 80 / 60.5 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Broan AE80B = A000HFKT with AE80BF1 | 80 / 60.5 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Broan AE80B = A000HFKTC WITH AE80BF1 | 80 / 60.5 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Broan AE80B = A000HFNF with AE80BF1 | 80 / 60.5 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Broan AE80BR | 80 / 60.5 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
Can you size Milano TY-80-EH for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against Milano TY-80-EH verified capacity.
What plumbing or duct constraints rule out Milano TY-80-EH?
Compare where Milano TY-80-EH excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 59.4 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Homeowner profile: Target comfort around 0.7 sones up to 59 sq ft
- Suited to: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to Milano TY-80-EH?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for Milano TY-80-EH.
Is Milano TY-80-EH energy-efficient for continuous ASHRAE 62.2 operation?
At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.
Can Milano TY-80-EH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Milano TY-80-EH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Milano TY-80-EH?
Milano TY-80-EH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Milano TY-80-EH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Milano TY-80-EH's safe coverage footprint from 50 sq ft to 44 sq ft.
Can Milano TY-80-EH serve as primary ventilation for a full bathroom?
Yes up to 50 sq ft on 8-ft ceilings: Milano TY-80-EH supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.
Why might a contractor swap Milano TY-80-EH for a higher-CFM unit?
If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Milano TY-80-EH lacks adequate reserve.
How does Milano TY-80-EH handle 0.25 in. w.g. duct static pressure loss?
Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Milano TY-80-EH yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.
Is Milano TY-80-EH quiet enough for a primary bedroom bathroom?
At 0.7 sones, Milano TY-80-EH operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)