Skip to main content
Grant Estimator

Broan AE80B Exhaust Fan Specifications

ENERGY STAR PD #2524266 · Bathroom/Utility Room · Qualified 2023-06-23
Verified Specification Summary

In EPA dataset 8dv7-nngq, Broan AE80B tests at 80 CFM free discharge (60.5 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 3.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 60 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80B Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 60.5 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
3.3 CFM/W (#1,077/1,145)
Static Retention
75.6% @ 0.25"
Motor Draw
24.2 W (8.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE80B vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60.5 CFM at 0.25 in. w.g. (75.6% retention, 12.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Certification audit confirms Broan AE80B (series: FLEX) under PD #2524266 (207 models registered, 2023-06-23). Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.2 watts, about 8.8 kWh/yr (~$1.41/yr at $0.16/kWh) for 1 hr/day shower timers or 212.0 kWh/yr (~$33.92/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).

Does Broan AE80B fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Broan AE80B at 0.7 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

Why avoid unvented attic termination with Broan AE80B?

Under ASHRAE 62.2 best practice, Broan AE80B needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Broan AE80B?

Before cutting ceiling drywall or sizing attic transitions for Broan AE80B, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE80B / FLEX PD ID 2524266 (Qualified 2023-06-23)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (60.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

What daily runtime and room footprint suit Broan AE80B?

Bathroom ventilation sizing below maps Broan AE80B motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Broan AE80B
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 60 sq ft1 CFM/sq ft @ 60.5 CFM
Tall Bath (9-ft Ceiling)Up to 53 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.8 kWh/yr (~$1.41/yr)24.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2212.0 kWh/yr (~$33.92/yr)24.2 W x 8,760 hrs / 1,000

What peer models sit nearest Broan AE80B in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Broan AE80B.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Milano TY-80-E 80 / 59.4 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Milano TY-80-EH 80 / 59.4 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Hunter 90704 80 / 70.5 CFM 0.6 sones (-0.10) 3.5 CFM/W 4 in. diameter
Hunter 90705 80 / 70.5 CFM 0.6 sones (-0.10) 3.5 CFM/W 4 in. diameter
Nutone AER80LWH 80 / 59.4 CFM 0.8 sones (+0.10) 3.5 CFM/W 4 in. diameter

What percentage of room demand does Broan AE80B cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Broan AE80B tested delivery.

What plumbing or duct constraints rule out Broan AE80B?

Compare where Broan AE80B excels against structural, acoustic, or mechanical bottlenecks that demand selecting an alternative certified residential model.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 60.5 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Homeowner profile: Target comfort around 0.7 sones up to 60 sq ft
  • Suited to: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Broan AE80B?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Broan AE80B.

Is Broan AE80B quiet enough for a primary bedroom bathroom?

At 0.7 sones, Broan AE80B operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan; because sones scale linearly, <=1.0 sone models sound roughly three times quieter than 3.0 sone builder units.

Is Broan AE80B energy-efficient for continuous ASHRAE 62.2 operation?

At ENERGY STAR airflow verification, yearly energy totals roughly continuous ASHRAE duty if run continuously (8,760 hours) or low intermittent draw on 365-hour intermittent shower timers.

Can Broan AE80B pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80B's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE80B?

Broan AE80B features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE80B's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80B's safe coverage footprint from 50 sq ft to 44 sq ft.

Can Broan AE80B serve as primary ventilation for a full bathroom?

Yes up to 50 sq ft on 8-ft ceilings: Broan AE80B supplies 50 CFM net output (50 CFM @ 0.1 in.; unlisted 0.25 in. w.g. backpressure figures) and clears the 50 CFM IRC M1505 intermittent requirement.

Why might a contractor swap Broan AE80B for a higher-CFM unit?

If a remodel encloses a walk-in tub (+50 CFM reserve), exceeds 50 sq ft (or 44 sq ft at 9-ft ceilings), or faces long static roof runs, Broan AE80B lacks adequate reserve.

How does Broan AE80B handle 0.25 in. w.g. duct static pressure loss?

Open-air 0.1 in. w.g. output (50 CFM) drops once duct elbows and exterior dampers add friction. At 0.25 in. w.g., Broan AE80B yields unlisted 0.25 in. w.g. backpressure figures, so smooth 4 in. diameter rigid metal ducting protects real exhaust.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories