The Nutone AER80LWH (DECORATIVE) moves 80 CFM at 0.1 in. w.g. (59.4 CFM at 0.25 in. w.g.), registers #194 of 607 in quietness (0.8 sones), and delivers 3.5 CFM/W efficacy, sizing bathrooms up to 59 sq ft (8-ft ceilings) under IRC M1505 and ASHRAE 62.2. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Nutone AER80LWH Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 59.4 CFM
- Noise @ 0.1"
- 0.8 sones (#194/607)
- Efficacy Rank
- 3.5 CFM/W (#1,038/1,145)
- Static Retention
- 74.2% @ 0.25"
- Motor Draw
- 22.9 W (8.4 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Nutone AER80LWH vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.8 sones (#194 of 607 rated models, quietest 39.2% of 607 rated models, quieter than 60.8% of rated models, 0.20 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.4 CFM at 0.25 in. w.g. (74.2% retention, 13.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Nutone registers 16 certified models, with SKU AER80LWH (series: DECORATIVE) (PD #2344279) certified since 2019-06-28. Lighting kit: Yes. At 3.5 CFM/W (#1,038 of 1,145, below median tier among 1,145 rated models; more efficient than 7.5% of rated models, 1.2 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 22.9 watts, about 8.4 kWh/yr (~$1.34/yr at $0.16/kWh) for 1 hr/day shower timers or 200.6 kWh/yr (~$32.10/yr) continuously. Closest competing matches include Broan AER80LMB (80.0 CFM) and S&P PC80XP (80.0 CFM).
Where does Nutone AER80LWH sit on the 1,145-model ENERGY STAR sone curve?
Quiet bedroom-adjacent models score 1.0 sone or lower (356 certified fans nationwide). This model sits at 0.8 sones against all 1,145 EPA listings.
How does duct geometry alter Nutone AER80LWH static pressure?
Smooth 4 in. diameter galvanized ducts terminated outdoors preserve rated CFM at 0.25 in. w.g., whereas sagging 3-in attic flex chokes airflow below IRC M1505 minimums.
Which certified test ratings apply to Nutone AER80LWH?
Review EPA ENERGY STAR ducted airflow, sound sones, electrical efficacy, and collar fit for Nutone AER80LWH alongside residential IRC M1505 and ASHRAE 62.2 ventilation benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Nutone (16 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AER80LWH / DECORATIVE | PD ID 2344279 (Qualified 2019-06-28) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (59.4 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.8 sones) | Fleet median 1.0 sones |
| Integrated Lighting | Yes | Verify switched neutral wiring |
How much bathroom area can Nutone AER80LWH ventilate safely?
Sizing outputs below convert Nutone AER80LWH tested CFM and motor watts into maximum 8-ft and 9-ft ceiling footprints plus annual kWh energy totals.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 59 sq ft | 1 CFM/sq ft @ 59.4 CFM |
| Tall Bath (9-ft Ceiling) | Up to 52 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.4 kWh/yr (~$1.34/yr) | 22.9 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 200.6 kWh/yr (~$32.10/yr) | 22.9 W x 8,760 hrs / 1,000 |
Which ENERGY STAR fans match Nutone AER80LWH closely?
Comparable certified models below pair similar airflow capacity, acoustic sone ratings, and motor efficacy so homeowners can cross-check contractor substitutions.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Broan AER80LMB | 80 / 59.4 CFM | 0.8 sones (Same) | 3.5 CFM/W | 4 in. diameter |
| S&P PC80XP | 80 / 65.7 CFM | 0.8 sones (Same) | 3.8 CFM/W | 4 in. diameter |
| Broan AE80B | 80 / 60.5 CFM | 0.7 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| Broan AE80B = A000HFKT with AE80BF1 | 80 / 60.5 CFM | 0.7 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
| Broan AE80B = A000HFKTC WITH AE80BF1 | 80 / 60.5 CFM | 0.7 sones (-0.10) | 3.3 CFM/W | 4 in. diameter |
Will Nutone AER80LWH clear IRC M1505 in your bathroom?
Enter your room floor area and ceiling height below to verify whether Nutone AER80LWH satisfies ASHRAE 62.2 and residential IRC M1505 airflow rules locally.
Which bath layouts should avoid specifying Nutone AER80LWH?
Match Nutone AER80LWH directly against your home's framing clearances, hot-water tank recovery rate, and local municipal inspection tolerances.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Best for: Bathroom floor <= 59 sq ft with 8-ft ceilings (52 sq ft at 9-ft height)
- Optimal use: Exterior run uses smooth rigid metal matched to 4 in. diameter
What key rules and numbers govern Nutone AER80LWH?
Answers below summarize primary U.S. agency datasets, statutory limits, and residential IRC, IPC, or NEC building rules affecting Nutone AER80LWH.
Where does Nutone AER80LWH sit on acoustic comfort for senior homeowners?
Measuring 0.8 sones, Nutone AER80LWH operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan, avoiding the harsh hum common in older 3.0-to-4.0 sone bath fans.
What does Nutone AER80LWH cost in annual electricity for intermittent vs continuous duty?
Operating at ENERGY STAR airflow verification, running Nutone AER80LWH 1 hour daily uses ~low intermittent draw, whereas 24/7 ASHRAE 62.2 continuous exhaust consumes ~continuous ASHRAE duty across 8,760 annual hours at your local kWh rate.
Can Nutone AER80LWH pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Nutone AER80LWH's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Nutone AER80LWH?
Nutone AER80LWH features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Nutone AER80LWH's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Nutone AER80LWH's safe coverage footprint from 50 sq ft to 44 sq ft.
What bathroom square footage can Nutone AER80LWH ventilate under ASHRAE 62.2?
Rated at 50 CFM effective capacity (unlisted 0.25 in. w.g. backpressure figures), Nutone AER80LWH covers up to 50 sq ft with standard 8-ft ceilings and clears the 50 CFM intermittent code benchmark.
Where does Nutone AER80LWH run out of capacity in residential remodeling?
Homeowners with baths exceeding 50 sq ft, 9-foot ceilings above 44 sq ft, or walk-in tubs requiring +50 CFM moisture reserve should step up rather than undersizing with Nutone AER80LWH.
What happens to Nutone AER80LWH CFM when vented through elbows and roof caps?
Against realistic 0.25 in. w.g. system resistance, Nutone AER80LWH moves unlisted 0.25 in. w.g. backpressure figures compared to its 50 CFM free-discharge spec, avoid sharp flex bends on its 4 in. diameter collar.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)