Rated for 80 CFM open-air (60.5 CFM at 0.25 in. w.g.), Broan AE80B = A000HFKTC WITH AE80BF1 registers #135 of 607 in quietness (0.7 sones) and delivers 3.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80B = A000HFKTC WITH AE80BF1 Exhaust Fan before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 60.5 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 3.3 CFM/W (#1,077/1,145)
- Static Retention
- 75.6% @ 0.25"
- Motor Draw
- 24.2 W (8.8 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does Broan AE80B = A000HFKTC WITH AE80BF1 vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60.5 CFM at 0.25 in. w.g. (75.6% retention, 12.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
Brand catalog footprint: Broan registers 207 certified models, with SKU AE80B = A000HFKTC WITH AE80BF1 (series: FLEX SERIES) (PD #3999570) certified since 2025-03-07. Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.2 watts, about 8.8 kWh/yr (~$1.41/yr at $0.16/kWh) for 1 hr/day shower timers or 212.0 kWh/yr (~$33.92/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).
How does Broan AE80B = A000HFKTC WITH AE80BF1 acoustic output align with quiet <=1.0 sone models?
Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan AE80B = A000HFKTC WITH AE80BF1 (0.7 sones).
How do flex elbows choke Broan AE80B = A000HFKTC WITH AE80BF1 at 0.25 in. w.g.?
Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan AE80B = A000HFKTC WITH AE80BF1 moving full rated CFM.
Does Broan AE80B = A000HFKTC WITH AE80BF1 meet residential exhaust fan code specs?
Inspect Broan AE80B = A000HFKTC WITH AE80BF1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | Broan (207 models) | ENERGY STAR Certified Partner |
| Model Number & Series | AE80B = A000HFKTC WITH AE80BF1 / FLEX SERIES | PD ID 3999570 (Qualified 2025-03-07) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (60.5 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
Which bathroom duties match Broan AE80B = A000HFKTC WITH AE80BF1 airflow output?
Annual electricity figures and room square-footage ceilings below reflect Broan AE80B = A000HFKTC WITH AE80BF1 tested efficacy under both 1-hour daily intermittent use and continuous operation.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 60 sq ft | 1 CFM/sq ft @ 60.5 CFM |
| Tall Bath (9-ft Ceiling) | Up to 53 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 8.8 kWh/yr (~$1.41/yr) | 24.2 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 212.0 kWh/yr (~$33.92/yr) | 24.2 W x 8,760 hrs / 1,000 |
Which competing models share Broan AE80B = A000HFKTC WITH AE80BF1 airflow and noise class?
Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| Milano TY-80-E | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Milano TY-80-EH | 80 / 59.4 CFM | 0.7 sones (Same) | 3.3 CFM/W | 4 in. diameter |
| Hunter 90704 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Hunter 90705 | 80 / 70.5 CFM | 0.6 sones (-0.10) | 3.5 CFM/W | 4 in. diameter |
| Nutone AER80LWH | 80 / 59.4 CFM | 0.8 sones (+0.10) | 3.5 CFM/W | 4 in. diameter |
How much airflow margin does Broan AE80B = A000HFKTC WITH AE80BF1 give your bath?
Run a quick local room-volume check for Broan AE80B = A000HFKTC WITH AE80BF1 by entering square footage and ceiling height to spot under-vented steam risks early.
Does Broan AE80B = A000HFKTC WITH AE80BF1 suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan AE80B = A000HFKTC WITH AE80BF1 for your remodel.
Limitations & Who Should Skip
- Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
- Existing attic run relies on >15 ft of 3-inch corrugated flex
Best-Fit Homeowner Profiles
- Strong scenario: Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
- Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter
What should homeowners verify first about Broan AE80B = A000HFKTC WITH AE80BF1?
Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan AE80B = A000HFKTC WITH AE80BF1.
What acoustic sone tier does Broan AE80B = A000HFKTC WITH AE80BF1 occupy in EPA filings?
With 0.7 sones at 0.1 in. w.g., Broan AE80B = A000HFKTC WITH AE80BF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does Broan AE80B = A000HFKTC WITH AE80BF1 add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, Broan AE80B = A000HFKTC WITH AE80BF1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can Broan AE80B = A000HFKTC WITH AE80BF1 pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80B = A000HFKTC WITH AE80BF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing Broan AE80B = A000HFKTC WITH AE80BF1?
Broan AE80B = A000HFKTC WITH AE80BF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change Broan AE80B = A000HFKTC WITH AE80BF1's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80B = A000HFKTC WITH AE80BF1's safe coverage footprint from 50 sq ft to 44 sq ft.
Does Broan AE80B = A000HFKTC WITH AE80BF1 pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan AE80B = A000HFKTC WITH AE80BF1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install Broan AE80B = A000HFKTC WITH AE80BF1 in a bathroom remodel?
Avoid specifying Broan AE80B = A000HFKTC WITH AE80BF1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut Broan AE80B = A000HFKTC WITH AE80BF1 airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan AE80B = A000HFKTC WITH AE80BF1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)