Skip to main content
Grant Estimator

Broan AE80B = A000HFKTC WITH AE80BF1 Exhaust Fan Specifications

ENERGY STAR PD #3999570 · Bathroom/Utility Room · Qualified 2025-03-07
Verified Specification Summary

Rated for 80 CFM open-air (60.5 CFM at 0.25 in. w.g.), Broan AE80B = A000HFKTC WITH AE80BF1 registers #135 of 607 in quietness (0.7 sones) and delivers 3.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 60 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Broan AE80B = A000HFKTC WITH AE80BF1 Exhaust Fan before installation.

Airflow @ 0.1" / 0.25"
80 / 60.5 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
3.3 CFM/W (#1,077/1,145)
Static Retention
75.6% @ 0.25"
Motor Draw
24.2 W (8.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Broan AE80B = A000HFKTC WITH AE80BF1 vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 60.5 CFM at 0.25 in. w.g. (75.6% retention, 12.1 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Brand catalog footprint: Broan registers 207 certified models, with SKU AE80B = A000HFKTC WITH AE80BF1 (series: FLEX SERIES) (PD #3999570) certified since 2025-03-07. Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.2 watts, about 8.8 kWh/yr (~$1.41/yr at $0.16/kWh) for 1 hr/day shower timers or 212.0 kWh/yr (~$33.92/yr) continuously. Closest competing matches include Milano TY-80-E (80.0 CFM) and Milano TY-80-EH (80.0 CFM).

How does Broan AE80B = A000HFKTC WITH AE80BF1 acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Broan AE80B = A000HFKTC WITH AE80BF1 (0.7 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

How do flex elbows choke Broan AE80B = A000HFKTC WITH AE80BF1 at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Broan AE80B = A000HFKTC WITH AE80BF1 moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Broan AE80B = A000HFKTC WITH AE80BF1 meet residential exhaust fan code specs?

Inspect Broan AE80B = A000HFKTC WITH AE80BF1 mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Broan (207 models) ENERGY STAR Certified Partner
Model Number & Series AE80B = A000HFKTC WITH AE80BF1 / FLEX SERIES PD ID 3999570 (Qualified 2025-03-07)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (60.5 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Broan AE80B = A000HFKTC WITH AE80BF1 airflow output?

Annual electricity figures and room square-footage ceilings below reflect Broan AE80B = A000HFKTC WITH AE80BF1 tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Broan AE80B = A000HFKTC WITH AE80BF1
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 60 sq ft1 CFM/sq ft @ 60.5 CFM
Tall Bath (9-ft Ceiling)Up to 53 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.8 kWh/yr (~$1.41/yr)24.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2212.0 kWh/yr (~$33.92/yr)24.2 W x 8,760 hrs / 1,000

Which competing models share Broan AE80B = A000HFKTC WITH AE80BF1 airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Milano TY-80-E 80 / 59.4 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Milano TY-80-EH 80 / 59.4 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Hunter 90704 80 / 70.5 CFM 0.6 sones (-0.10) 3.5 CFM/W 4 in. diameter
Hunter 90705 80 / 70.5 CFM 0.6 sones (-0.10) 3.5 CFM/W 4 in. diameter
Nutone AER80LWH 80 / 59.4 CFM 0.8 sones (+0.10) 3.5 CFM/W 4 in. diameter

How much airflow margin does Broan AE80B = A000HFKTC WITH AE80BF1 give your bath?

Run a quick local room-volume check for Broan AE80B = A000HFKTC WITH AE80BF1 by entering square footage and ceiling height to spot under-vented steam risks early.

Does Broan AE80B = A000HFKTC WITH AE80BF1 suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Broan AE80B = A000HFKTC WITH AE80BF1 for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 60 sq ft with 8-ft ceilings (53 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Broan AE80B = A000HFKTC WITH AE80BF1?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Broan AE80B = A000HFKTC WITH AE80BF1.

What acoustic sone tier does Broan AE80B = A000HFKTC WITH AE80BF1 occupy in EPA filings?

With 0.7 sones at 0.1 in. w.g., Broan AE80B = A000HFKTC WITH AE80BF1 operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Broan AE80B = A000HFKTC WITH AE80BF1 add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Broan AE80B = A000HFKTC WITH AE80BF1 averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Broan AE80B = A000HFKTC WITH AE80BF1 pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Broan AE80B = A000HFKTC WITH AE80BF1's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Broan AE80B = A000HFKTC WITH AE80BF1?

Broan AE80B = A000HFKTC WITH AE80BF1 features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Broan AE80B = A000HFKTC WITH AE80BF1's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Broan AE80B = A000HFKTC WITH AE80BF1's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Broan AE80B = A000HFKTC WITH AE80BF1 pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Broan AE80B = A000HFKTC WITH AE80BF1 easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Broan AE80B = A000HFKTC WITH AE80BF1 in a bathroom remodel?

Avoid specifying Broan AE80B = A000HFKTC WITH AE80BF1 in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Does duct resistance cut Broan AE80B = A000HFKTC WITH AE80BF1 airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Broan AE80B = A000HFKTC WITH AE80BF1 achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories