Skip to main content
Grant Estimator

Milano TY-80-E Exhaust Fan Specifications

ENERGY STAR PD #2343151 · Bathroom/Utility Room · Qualified 2018-05-25
Verified Specification Summary

Rated for 80 CFM open-air (59.4 CFM at 0.25 in. w.g.), Milano TY-80-E registers #135 of 607 in quietness (0.7 sones) and delivers 3.3 CFM/W efficacy. Under ASHRAE 62.2 and IRC M1505 guidelines, effective airflow supports up to 59 sq ft at 8-ft ceiling height. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Milano TY-80-E Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 59.4 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
3.3 CFM/W (#1,077/1,145)
Static Retention
74.2% @ 0.25"
Motor Draw
24.2 W (8.8 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Milano TY-80-E vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Expect noticeable duct drag: airflow moves from 80 CFM open-air to 59.4 CFM at 0.25 in. w.g. (74.2% retention, 13.5 pts lower retention than the 87.7% median), making smooth 4 in. diameter rigid metal runs critical. Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Inside Milano's 6-unit lineup, TY-80-E (series: Slim fan easy installation) carries PD #2343151 dating to 2018-05-25. Lighting kit: No. At 3.3 CFM/W (#1,077 of 1,145, below median tier among 1,145 rated models; more efficient than 4.8% of rated models, 1.4 CFM/W less efficient than the 4.7 CFM/W median), electrical draw computes to 24.2 watts, about 8.8 kWh/yr (~$1.41/yr at $0.16/kWh) for 1 hr/day shower timers or 212.0 kWh/yr (~$33.92/yr) continuously. Closest competing matches include Broan AE80B (80.0 CFM) and Broan AE80B = A000HFKT with AE80BF1 (80.0 CFM).

How does Milano TY-80-E acoustic output align with quiet <=1.0 sone models?

Sone histograms across 1,145 ENERGY STAR fans show 356 units at <=1.0 sone compared against Milano TY-80-E (0.7 sones).

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

How do flex elbows choke Milano TY-80-E at 0.25 in. w.g.?

Every sharp flex elbow raises static resistance past 0.25 in. w.g.; rigid 4 in. diameter metal pipe keeps Milano TY-80-E moving full rated CFM.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

Does Milano TY-80-E meet residential exhaust fan code specs?

Inspect Milano TY-80-E mechanical compliance across 50 CFM intermittent and 20 CFM continuous IRC M1505 minimums, acoustic sone targets, and rigid duct collar transitions.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Milano (6 models) ENERGY STAR Certified Partner
Model Number & Series TY-80-E / Slim fan easy installation PD ID 2343151 (Qualified 2018-05-25)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (59.4 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting No Verify switched neutral wiring

Which bathroom duties match Milano TY-80-E airflow output?

Annual electricity figures and room square-footage ceilings below reflect Milano TY-80-E tested efficacy under both 1-hour daily intermittent use and continuous operation.

Bathroom sizing limits and annual kWh draw for Milano TY-80-E
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 59 sq ft1 CFM/sq ft @ 59.4 CFM
Tall Bath (9-ft Ceiling)Up to 52 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)8.8 kWh/yr (~$1.41/yr)24.2 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2212.0 kWh/yr (~$33.92/yr)24.2 W x 8,760 hrs / 1,000

Which competing models share Milano TY-80-E airflow and noise class?

Homeowners weighing replacement units or contractor quotes can compare five closely matched ENERGY STAR exhaust blowers listed with exact sone deltas below.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Broan AE80B 80 / 60.5 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Broan AE80B = A000HFKT with AE80BF1 80 / 60.5 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Broan AE80B = A000HFKTC WITH AE80BF1 80 / 60.5 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Broan AE80B = A000HFNF with AE80BF1 80 / 60.5 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter
Broan AE80BR 80 / 60.5 CFM 0.7 sones (Same) 3.3 CFM/W 4 in. diameter

How much airflow margin does Milano TY-80-E give your bath?

Run a quick local room-volume check for Milano TY-80-E by entering square footage and ceiling height to spot under-vented steam risks early.

Does Milano TY-80-E suit every home layout, or when should you skip it?

Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying Milano TY-80-E for your remodel.

Limitations & Who Should Skip

  • Enclosed walk-in tub or steam room (+50 CFM reserve requires >=70 CFM net fan)
  • Existing attic run relies on >15 ft of 3-inch corrugated flex

Best-Fit Homeowner Profiles

  • Strong scenario: Bathroom floor <= 59 sq ft with 8-ft ceilings (52 sq ft at 9-ft height)
  • Best application: Exterior run uses smooth rigid metal matched to 4 in. diameter

What should homeowners verify first about Milano TY-80-E?

Each factual question and answer below cites verified federal agency thresholds, inspection rules, and practical installation warnings relevant to Milano TY-80-E.

Does duct resistance cut Milano TY-80-E airflow at 0.25 in. w.g.?

Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, Milano TY-80-E achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.

What acoustic sone tier does Milano TY-80-E occupy in EPA filings?

With 0.7 sones at 0.1 in. w.g., Milano TY-80-E operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.

How many kWh per year does Milano TY-80-E add to a utility bill?

With ENERGY STAR airflow verification motor efficiency, Milano TY-80-E averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.

Can Milano TY-80-E pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Milano TY-80-E's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Milano TY-80-E?

Milano TY-80-E features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Milano TY-80-E's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Milano TY-80-E's safe coverage footprint from 50 sq ft to 44 sq ft.

Does Milano TY-80-E pass ASHRAE 62.2 continuous and intermittent duty limits?

At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), Milano TY-80-E easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.

Who should NOT install Milano TY-80-E in a bathroom remodel?

Avoid specifying Milano TY-80-E in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories