Haier QVE801DTWW Exhaust Fan Specifications

ENERGY STAR PD #2392687 · Bathroom/Utility Room · Qualified 2022-01-21
Verified Specification Summary

In EPA dataset 8dv7-nngq, Haier QVE801DTWW tests at 80 CFM free discharge (68.9 CFM at 0.25 in. w.g.) and registers #135 of 607 in quietness (0.7 sones) and delivers 5.3 CFM/W efficacy, meeting residential IRC M1505 sizing up to 68 sq ft. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside Haier QVE801DTWW Exhaust Fan Specifications before installation.

Airflow @ 0.1" / 0.25"
80 / 68.9 CFM
Noise @ 0.1"
0.7 sones (#135/607)
Efficacy Rank
5.3 CFM/W (#494/1,145)
Static Retention
86.1% @ 0.25"
Motor Draw
15.1 W (5.5 kWh/yr)
Duct & Tier
4 in. diameter · Standard
Flush matte white bathroom exhaust fan grille mounted cleanly in a finished bathroom ceiling
Insulated 4-inch galvanized attic exhaust duct vented cleanly to an exterior damper cap.

What does Haier QVE801DTWW vs. 1,145-Model ENERGY STAR Benchmarks show?

Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.

Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.9 CFM out of 80 CFM (86.1% retention, 1.6 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.

Manufacturer coverage places QVE801DTWW (series: QVE) (PD #2392687) among 2 Haier entries qualified through 2022-01-21. Lighting kit: Yes. At 5.3 CFM/W (#494 of 1,145, top 43.5% of 1,145 rated models, more efficient than 56.5% of rated models, 0.6 CFM/W more efficient than the 4.7 CFM/W median), electrical draw computes to 15.1 watts, about 5.5 kWh/yr (~$0.88/yr at $0.16/kWh) for 1 hr/day shower timers or 132.3 kWh/yr (~$21.17/yr) continuously. Closest competing matches include Anzzi EF-AZ101WH (80.0 CFM) and Aria QBV0800 (80.0 CFM).

Does Haier QVE801DTWW fall inside the quiet <=1.0 sone ENERGY STAR tier?

Acoustic distribution across 1,145 ENERGY STAR models contrasts quiet <=1.0 sone ECM fans with Haier QVE801DTWW at 0.7 sones.

Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath FansHistogram of 607 items for Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fans. Min 0 sones, median 1 sones, max 2.8 sones. Marker This fan: 0.7 sone: 0.7 sones (32nd percentile).Acoustic Rating Distribution Across 1,145 ENERGY STAR Bath Fansn=607 · median 1 sones0651300 sones to 0.23 sones: 230.23 sones to 0.47 sones: 590.47 sones to 0.7 sones: 520.7 sones to 0.93 sones: 1300.93 sones to 1.17 sones: 1151.17 sones to 1.4 sones: 251.4 sones to 1.63 sones: 1131.63 sones to 1.87 sones: 21.87 sones to 2.1 sones: 842.1 sones to 2.33 sones: 22.33 sones to 2.57 sones: 12.57 sones to 2.8 sones: 10 sones1.4 sones2.8 sonesThis fan: 0.7 sone: 0.7 sones (P32)

Why avoid unvented attic termination with Haier QVE801DTWW?

Under ASHRAE 62.2 best practice, Haier QVE801DTWW needs insulated 4 in. diameter rigid ducting vented outdoors—never dumping humid bath air into open attics.

Bathroom Exhaust Fan Static Pressure and Duct Geometry Schematic Comparison showing smooth 4-inch or 6-inch rigid galvanized duct preserving airflow at 0.25 in. w.g. to an exterior roof cap versus choked 3-inch flex duct venting improperly into attic insulation. Target: Rigid 4-in / 6-in Outdoors Damper Roof Cap Fan <= 1.0 Sone Retains ~82%+ CFM @ 0.25 in. w.g. Smooth galvanized steel Defect: 3-in Flex / Attic Vent Mold & Frost Inside Attic Builder 3.0 Sone Choked static drop <50 CFM
Architectural duct layout illustrating IRC M1505 / ASHRAE 62.2 exterior termination and 0.25 in. w.g. static pressure preservation.

What installation parameters govern Haier QVE801DTWW?

Before cutting ceiling drywall or sizing attic transitions for Haier QVE801DTWW, confirm rated CFM at 0.25 in. w.g., sound sones, and switched lighting circuit details.

Verified specifications and code or agency threshold checks
ParameterVerified ValueReference Standard / Note
Manufacturer / Brand Share Haier (2 models) ENERGY STAR Certified Partner
Model Number & Series QVE801DTWW / QVE PD ID 2392687 (Qualified 2022-01-21)
Duct Connection 4 in. diameter Use smooth rigid metal outdoors
IRC M1505 (>=50 CFM) Check PASS (68.9 CFM) DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505)
Acoustic Suite (<=1.0 Sone) YES (0.7 sones) Fleet median 1.0 sones
Integrated Lighting Yes Verify switched neutral wiring

What daily runtime and room footprint suit Haier QVE801DTWW?

Bathroom ventilation sizing below maps Haier QVE801DTWW motor wattage across 365 intermittent hours or 8,760 continuous hours while tracking square-foot coverage caps.

Bathroom sizing limits and annual kWh draw for Haier QVE801DTWW
Bathroom Duty / ScenarioMax Room Size / OutputStatic & Cost Basis
Standard Bath (8-ft Ceiling)Up to 68 sq ft1 CFM/sq ft @ 68.9 CFM
Tall Bath (9-ft Ceiling)Up to 61 sq ftScaled +12.5% volume factor
Walk-In Tub / Steam (+50 CFM)Not suited (+50 CFM leaves <20 sq ft)Subtracts 50 CFM moisture reserve
Intermittent Use (1 hr/day)5.5 kWh/yr (~$0.88/yr)15.1 W x 365 hrs / 1,000
Continuous 24/7 ASHRAE 62.2132.3 kWh/yr (~$21.17/yr)15.1 W x 8,760 hrs / 1,000

What peer models sit nearest Haier QVE801DTWW in EPA test files?

Matched across airflow, sone loudness, and CFM/W efficiency, these five ENERGY STAR ventilating fans provide direct engineering alternatives to Haier QVE801DTWW.

Nearest peers matched by CFM airflow, acoustic sones, and motor efficacy
Peer Brand & ModelCFM (0.1" / 0.25")Sones (Delta)EfficacyDuct
Anzzi EF-AZ101WH 80 / 68.9 CFM 0.7 sones (Same) 5.3 CFM/W 4 in. diameter
Aria QBV0800 80 / 68.9 CFM 0.7 sones (Same) 5.3 CFM/W 4 in. diameter
Canarm CNP80 80 / 62.6 CFM 0.7 sones (Same) 4.9 CFM/W 4 in. diameter
ACIQ AES80 80 / 68.3 CFM 0.7 sones (Same) 4.7 CFM/W 4 in. diameter
CFM TF80N 80 / 68.3 CFM 0.7 sones (Same) 4.7 CFM/W 4 in. diameter

What percentage of room demand does Haier QVE801DTWW cover?

Type your bathroom area and ceiling height below to compare required ASHRAE 62.2 airflow directly against Haier QVE801DTWW tested delivery.

Where should contractors skip Haier QVE801DTWW on bath bids?

Inspect technical exclusions, installation bottlenecks, and best-fit bathroom scenarios for Haier QVE801DTWW carefully below before approving contractor material schedules.

Limitations & Who Should Skip

  • High-ceiling bath (10+ ft) pushing demand past 68.9 CFM
  • Sharp multiple 90-degree flex bends choking static pressure

Best-Fit Homeowner Profiles

  • Choose this if: Target comfort around 0.7 sones up to 68 sq ft
  • Works well for: Paired with rigid galvanized 4 in. diameter transition

Where do official rules set limits for Haier QVE801DTWW?

Browse concise, source-cited answers below grounded directly in public U.S. federal datasets and residential building standards governing Haier QVE801DTWW.

How does Haier QVE801DTWW score against federal 50 CFM intermittent fan rules?

Tested at 50 CFM open-air (unlisted 0.25 in. w.g. backpressure figures), Haier QVE801DTWW delivers 50 CFM usable airflow, meaning it clears IRC M1505 50 CFM intermittent thresholds in rooms up to 50 sq ft.

What duct and room conditions disqualify Haier QVE801DTWW?

Rule out Haier QVE801DTWW when long corrugated flex runs drop pressure past 0.25 in. w.g., ceiling heights shrink usable footprint below 44 sq ft, or room area tops 50 sq ft.

Will long attic ducting choke Haier QVE801DTWW capacity?

Because static drag at 0.25 in. w.g. lowers Haier QVE801DTWW from 50 CFM to unlisted 0.25 in. w.g. backpressure figures, installers should run smooth 4 in. diameter rigid ducting straight to a dedicated exterior damper.

How loud is Haier QVE801DTWW compared with a standard 3.0 sone builder fan?

Tested at 0.7 sones, Haier QVE801DTWW operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan. Acoustic sone numbers scale linearly with perceived loudness.

How much power does Haier QVE801DTWW consume per year at 1 hr/day vs 24/7?

Backed by ENERGY STAR airflow verification, Haier QVE801DTWW draws about low intermittent draw for 1-hour daily moisture clearing or continuous ASHRAE duty under continuous whole-home ventilation duty.

Can Haier QVE801DTWW pair with an enclosed walk-in tub or steam shower?

Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from Haier QVE801DTWW's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.

What duct diameter and termination rules apply when installing Haier QVE801DTWW?

Haier QVE801DTWW features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.

How does ceiling height above 8 feet change Haier QVE801DTWW's room sizing?

Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing Haier QVE801DTWW's safe coverage footprint from 50 sq ft to 44 sq ft.

Sources

  1. ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
  2. DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)

Comparable Bath & Kitchen Cost Directories