Tested under HVI protocols, the CFM TF80N exhaust unit achieves 80 CFM at 0.1 in. w.g. (68.3 CFM at 0.25 in. w.g.), registers #135 of 607 in quietness (0.7 sones) and delivers 4.7 CFM/W efficacy, covering standard baths up to 68 sq ft on a 4 in. diameter collar. Verify ducted airflow at 0.25 in. w.g., rigid galvanized pipe diameter, roof damper termination, and IRC M1505 / ASHRAE 62.2 room sizing requirements alongside CFM TF80N Exhaust Fan Specifications before installation.
- Airflow @ 0.1" / 0.25"
- 80 / 68.3 CFM
- Noise @ 0.1"
- 0.7 sones (#135/607)
- Efficacy Rank
- 4.7 CFM/W (#545/1,145)
- Static Retention
- 85.4% @ 0.25"
- Motor Draw
- 17.0 W (6.2 kWh/yr)
- Duct & Tier
- 4 in. diameter · Standard

What does CFM TF80N vs. 1,145-Model ENERGY STAR Benchmarks show?
Quiet-suite acoustic rating at 0.7 sones (#135 of 607 rated models, quietest 31.8% of 607 rated models, quieter than 68.2% of rated models, 0.30 sones quieter than the 1.00 sones median), well suited to daily shower rooms.
Strong static stability: under 0.25 in. w.g. duct backpressure it holds 68.3 CFM out of 80 CFM (85.4% retention, 2.3 pts lower retention than the 87.7% median). Keep 4 in. diameter smooth rigid sheet metal straight to an exterior roof or wall damper cap rather than saggy flex.
CFM maintains 4 active ENERGY STAR blowers; TF80N (series: TF) (PD #2384049) gained qualification on 2021-08-13. Lighting kit: No. At 4.7 CFM/W (#545 of 1,145, at the median tier among 1,145 rated models; more efficient than 49.6% of rated models, equal to the 4.7 CFM/W median), electrical draw computes to 17.0 watts, about 6.2 kWh/yr (~$0.99/yr at $0.16/kWh) for 1 hr/day shower timers or 148.9 kWh/yr (~$23.82/yr) continuously. Closest competing matches include ACIQ AES80 (80.0 CFM) and S&P PCLP80XP (80.0 CFM).
Where do CFM TF80N sones rank across EPA ENERGY STAR fans?
Comparing CFM TF80N (0.7 sones) against 1,145 certified blowers highlights whether motor noise stays quiet near primary bedrooms.
What attic duct routing preserves CFM TF80N CFM output?
Short straight 4 in. diameter duct paths retain up to ~82% of open-air capacity on CFM TF80N, preventing premature peeling paint and mold growth.
How does CFM TF80N measure up on airflow and noise ratings?
Each row below breaks down CFM TF80N certification records from EPA filing 8dv7-nngq, pairing open-air 0.1-inch and ducted 0.25-inch static values against fleet benchmarks.
| Parameter | Verified Value | Reference Standard / Note |
|---|---|---|
| Manufacturer / Brand Share | CFM (4 models) | ENERGY STAR Certified Partner |
| Model Number & Series | TF80N / TF | PD ID 2384049 (Qualified 2021-08-13) |
| Duct Connection | 4 in. diameter | Use smooth rigid metal outdoors |
| IRC M1505 (>=50 CFM) Check | PASS (68.3 CFM) | DOE/PNNL BASC (ASHRAE 62.2 / IRC M1505) |
| Acoustic Suite (<=1.0 Sone) | YES (0.7 sones) | Fleet median 1.0 sones |
| Integrated Lighting | No | Verify switched neutral wiring |
How does ceiling height affect CFM TF80N CFM capacity?
Using 0.25 in. w.g. static output where published, the table models 8-ft bath footprints, 9-ft tall ceilings, walk-in tub steam loads, and yearly electricity.
| Bathroom Duty / Scenario | Max Room Size / Output | Static & Cost Basis |
|---|---|---|
| Standard Bath (8-ft Ceiling) | Up to 68 sq ft | 1 CFM/sq ft @ 68.3 CFM |
| Tall Bath (9-ft Ceiling) | Up to 60 sq ft | Scaled +12.5% volume factor |
| Walk-In Tub / Steam (+50 CFM) | Not suited (+50 CFM leaves <20 sq ft) | Subtracts 50 CFM moisture reserve |
| Intermittent Use (1 hr/day) | 6.2 kWh/yr (~$0.99/yr) | 17.0 W x 365 hrs / 1,000 |
| Continuous 24/7 ASHRAE 62.2 | 148.9 kWh/yr (~$23.82/yr) | 17.0 W x 8,760 hrs / 1,000 |
How do nearby ENERGY STAR blowers compare against CFM TF80N?
Compare CFM TF80N side-by-side with five competing certified exhaust units matching its static pressure class and noise bracket across other brands.
| Peer Brand & Model | CFM (0.1" / 0.25") | Sones (Delta) | Efficacy | Duct |
|---|---|---|---|---|
| ACIQ AES80 | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| S&P PCLP80XP | 80 / 68.3 CFM | 0.7 sones (Same) | 4.7 CFM/W | 4 in. diameter |
| Air King AK80LS | 80 / 61.5 CFM | 0.7 sones (Same) | 4.5 CFM/W | 4 in. diameter |
| Canarm CNP80 | 80 / 62.6 CFM | 0.7 sones (Same) | 4.9 CFM/W | 4 in. diameter |
| Ortech ODE-8007 | 80 / 69.8 CFM | 0.7 sones (Same) | 4.3 CFM/W | 4 in. diameter |
Can you size CFM TF80N for a 9-ft or tall bath ceiling?
Adjust floor square footage and ceiling height right inside your browser to calculate required CFM against CFM TF80N verified capacity.
Does CFM TF80N suit every home layout, or when should you skip it?
Check installation limits, duct or supply constraints, and household suitability criteria below prior to buying CFM TF80N for your remodel.
Limitations & Who Should Skip
- High-ceiling bath (10+ ft) pushing demand past 68.3 CFM
- Sharp multiple 90-degree flex bends choking static pressure
Best-Fit Homeowner Profiles
- Strong scenario: Target comfort around 0.7 sones up to 68 sq ft
- Best application: Paired with rigid galvanized 4 in. diameter transition
How do federal and code standards apply to CFM TF80N?
Questions below translate EPA, BLS, VA, USDA, and residential building code requirements into plain homeowner guidance for CFM TF80N.
What acoustic sone tier does CFM TF80N occupy in EPA filings?
With 0.7 sones at 0.1 in. w.g., CFM TF80N operates in the quiet suite tier (<=1.0 sone), roughly one-third as loud as a 3.0 sone AC fan across residential exhaust installations.
How many kWh per year does CFM TF80N add to a utility bill?
With ENERGY STAR airflow verification motor efficiency, CFM TF80N averages low intermittent draw on 1 hr/day shower duty and continuous ASHRAE duty in continuous 24/7 mode.
Can CFM TF80N pair with an enclosed walk-in tub or steam shower?
Enclosed soaking basins and walk-in tubs add a +50 CFM moisture reserve under DOE/PNNL sizing guidance. Subtracting 50 CFM from CFM TF80N's 50 CFM leaves capacity for insufficient floor area (<20 sq ft), requiring a higher-CFM unit.
What duct diameter and termination rules apply when installing CFM TF80N?
CFM TF80N features a 4 in. diameter collar. Mechanical codes require venting insulated rigid ducting straight outdoors via a roof or wall damper cap, never into open attic framing or soffits.
How does ceiling height above 8 feet change CFM TF80N's room sizing?
Standard 1 CFM per sq ft charts assume 8-foot ceilings. A 9-foot ceiling adds 12.5% room volume, reducing CFM TF80N's safe coverage footprint from 50 sq ft to 44 sq ft.
Does CFM TF80N pass ASHRAE 62.2 continuous and intermittent duty limits?
At 50 CFM effective output (unlisted 0.25 in. w.g. backpressure figures), CFM TF80N easily passes 20 CFM continuous minimums and clears 50 CFM intermittent bath rules up to 50 sq ft.
Who should NOT install CFM TF80N in a bathroom remodel?
Avoid specifying CFM TF80N in oversized primary baths above 50 sq ft, rooms with 9-to-10-ft ceilings exceeding 44 sq ft, enclosed walk-in tub suites above 20 sq ft, or runs choked by 3-in flex ducting.
Does duct resistance cut CFM TF80N airflow at 0.25 in. w.g.?
Between 0.1 in. w.g. (50 CFM) and 0.25 in. w.g. ducted backpressure, CFM TF80N achieves unlisted 0.25 in. w.g. backpressure figures; matching a 4 in. diameter smooth galvanized pipe minimizes static pressure choke.
Sources
- ENERGY STAR Certified Ventilating Fans Dataset (8dv7-nngq) — U.S. EPA ENERGY STAR, 2026 Live Socrata API (retrieved 2026-11-23)
- DOE Building America Solution Center — Bathroom Exhaust Fans (ASHRAE 62.2 / IRC) — U.S. Dept. of Energy / PNNL, 2026 DOE PNNL (retrieved 2026-11-23)